Introduction

Isoflurane (ISO) and sevoflurane (SEVO) are chemically closely related volatile general anesthetics (VGAs) with distinct properties1,2. Like all other VGAs, ISO and SEVO achieve the anesthetic phenotype within a very narrow concentration range3. However, deviations in susceptibility to anesthetics exist: inbred strains of rodents differ in sensitivity to ISO4,5,6 and enflurane7. Individual mongrel cats show differential sensitivity to modern VGAs8 as do segregated human populations for SEVO9,10,11. These data raise the possibility that anesthetic sensitivity may behave like a quantitative trait12,13, as opposed to being mediated by a small number of discrete molecular targets. By contrast, Mendelian mutations have pronounced effects on the sensitivity to VGAs in model organisms14,15,16 and can result in life-threatening consequences17,18. Therefore, as for other xenobiotics19,20, genetic polymorphisms that place a phenotypically normal individual at increased risk for adverse effects from exposure to VGAs are likely to exist.

To facilitate research into anesthetic pharmacogenomics, we took advantage of the genetically accessible fruit fly Drosophila melanogaster. Flies are not humans, yet evolution has produced cellular and molecular mechanisms that are conserved between flies and humans. For example, 55% to 75% of disease-causing genes in humans have functional homologues in flies21. Furthermore, because of evolutionary conservation, findings initially made in flies have made possible clinically important discoveries in higher organisms. Therefore, we used flies to establish the extent to which key pharmacokinetic (PK: ‘how an organism affects a drug’) and pharmacodynamic (PD: ‘how a drug affects an organism’) properties of ISO and SEVO are conserved in flies. This included testing whether a hypomorphic mutation in Complex I of the mitochondrial electron transport chain (ETC) reproduces the hypersensitive phenotype observed in Caenorhabditis elegans, Mus musculus, and Homo sapiens22,23,24,25 as well as examining the variability of PK and PD properties in a natural fly population, the Drosophila Genetic Reference Panel (DGRP).

Our data reveal substantial variability of PK and PD profiles for ISO and SEVO among genetically diverse wild type flies and support the usefulness of flies for pharmacogenomic and toxicological research.

Results

Design of the Serial Anesthesia Array

To allow comparative studies of VGA pharmacology on a medium-throughput scale in Drosophila with different genetic backgrounds, we assembled the Serial Anesthesia Array from easily accessible components. In the configuration shown in Fig. 1A,B, the array has eight tube positions for experimental samples and one tube position for humidification of the carrier gas (8 + 1 configuration). The tubes are arranged in series with a total volume of 655 mL downstream of a vaporizer and an air cylinder. Each tube can hold thousands of flies, but we standardly used fewer than 100 flies per tube. The array provides a simple system with a small footprint capable of delivering any volatile agent with precise and flexible control of the dose (concentration X duration of exposure) simultaneously to multiple experimental samples, e.g. flies of different age, sex, or genotype. Furthermore, neither the concentration nor the duration of VGA administration is constrained by a behavioral endpoint (e.g. loss of postural control) that limits the dose of VGA that can be delivered in traditional inebriometer or separator devices26,27,28.

Figure 1
figure 1

The Serial Anesthesia Array. (A) Main components of the array are an agent-specific anesthetic vaporizer, flow meters, and a serial array of anesthetizing positions. The small footprint allows housing within a conventional fume hood. A compressed air cylinder supplies air via a pressure regulator to the flow meter. The vaporizer controls the vaporization of liquid anesthetics and accurately delivers a given concentration to the air flowing from the air cylinder. Anesthetizing positions are assembled out of 50 mL conical tubes with customized caps fitted with input and output ports made of polystyrene pipettes. The tubes are interconnected via the external pipette ends with Tygon tubing. Within each tube the upstream (inflow) port opening is positioned closer to the bottom than the downstream (outflow) port to facilitate complete gas exchange (inset diagram). A fine mesh covers outflow ports to prevent flies from escaping. The number of positions in the array is flexible. The standard 8 + 1 configuration is shown. (B) The first position in the array contains water to humidify the mixture of air and VGA, and the remaining positions are available for experimental samples. A flow indicator at the downstream end of the array monitors the activity of the system. (C) Quantification of the rise in ISO concentration in the downstream tube 8 with air flowing at 1.5 L/min. Black circles indicate gas chromatograph measurements of ISO concentration in tube 8 over time (n ≥ 2, R2 = 0.95). Gray triangles indicate the theoretical change in anesthetic concentration calculated using the equation CArray = CAF(1-e−T/τ) (see Materials and Methods for details), assuming a single compartment of equivalent volume.

Gas exchange in the array is rapid

We tested the dynamics of anesthetic delivery through the array by measuring the rise in anesthetic concentration in the most downstream position (tube 8) (Fig. 1A,B). Analysis by gas chromatography showed that the ISO concentration rose with a time constant τ of 0.83 min (Fig. 1C). For a single compartment of the same volume (655 mL), the calculated τ would be 0.44 min. The slower than expected rise in ISO concentration is probably due to turbulence and inhomogeneity of gas exchange during the transition through nine separate tubes as opposed to uptake into flies whose biomass is negligible in comparison to the volume of the tubes. However, gas exchange was efficient enough to reach 95% of the set ISO concentration in the most downstream position within 2.5 min. We conclude that gas exchange in the array permits efficient and rapid administration of VGAs.

Behavioral assays as measures of anesthetic PK and PD

We developed behavioral assays to characterize the PK and PD of VGAs. Like the Dispersion assay developed by Nash and colleagues29, our Early Recovery Time and Percent Active assays are based on the innate, startle-induced climbing behavior of Drosophila. Contrary to the passive assays employed in inebriometer or separator chambers, which use loss of resistance to gravity as a measure of anesthetic depth30,31,32, our assays rely on the integrated function of different behaviors, including the escape reflex in response to mechanical stress, negative geotaxis proper (an innate orienting response and movement in opposition to gravitational cues), climbing ability, and locomotor activity itself, thereby capturing a more complex behavior.

Early Recovery Time is a measure of the time to recovery from a standard VGA dose (2% ISO or 3.5% SEVO for 1 hr) that produces deep anesthesia. After venting the anesthetic from the vial, startle-induced climbing behavior was elicited by manually tapping the vial on a rubber pad to knock the flies to the bottom of the vial once per minute until 6 of 60 flies (10%) were able to climb above 2 cm in 10 sec. Unanesthetized flies easily met this criterion upon the first tap. Thus, Early Recovery Time captures the PK of initial emergence from anesthesia.

The Percent Active is the percentage of 10 flies that climb above 2 cm in 1 min after climbing is elicited by manually tapping the vial. We used the Percent Active assay to determine the half-maximal time to recovery (TtR50). This was done by exposing flies to standard VGA concentrations (2% ISO or 3.5% SEVO) for 1 hr followed by venting the anesthetic from the vial and repeating the Percent Active measurement in the absence of anesthetic until all flies met the climbing criterion (above 2 cm in 1 min). The TtR50 is the amount of time needed for 50% of the flies in a vial to climb above 2 cm in 1 min, and it is an indication of the PK of extensive recovery from anesthesia.

We also used the Percent Active assay to determine the half-maximal effective concentration (EC50) of a VGA. This was done by exposing flies to different anesthetic concentrations for 10 min, measuring the Percent Active in the presence of anesthetic, increasing the anesthetic concentration, and repeating the Percent Active measurement until no flies met the climbing criterion (above 2 cm in 1 min). We chose a 10 min exposure to ensure complete equilibration of the fly brain with the VGA, which is estimated to take approximately 1 min33,34. The EC50 is an indication of the PD of induction of anesthesia.

The Serial Anesthesia Array delivers equivalent concentrations of anesthetic to all positions

We designed the Serial Anesthesia Array to compare anesthetic PK and PD on a medium-throughput experimental scale among different VGAs and different experimental samples. For the latter goal, it is important that all positions arranged in series in the array yield comparable experimental conditions. Therefore, we performed a functional characterization of the array by comparing Percent Active and Early Recovery Time measurements of w1118 flies (a standard laboratory strain) in different positions of the array. We found that the Percent Active did not differ between male flies exposed to 0.4% ISO for 10 min in the most upstream position (tube 1) and the most downstream position (tube 8) (42.09 ± 4.02 and 43.83 ± 4.31, respectively, Fig. 2A). Similarly, Early Recovery Time of mixed sex w1118 flies ranged from 19.0 ± 1.0 min to 25.0 ± 1.0 min but did not differ systematically among positions in the array (P = 0.36, one-way ANOVA) (Fig. 2B). In summary, these results indicate that the Serial Anesthesia Array rapidly delivers equivalent doses of anesthetic to flies in all positions, thereby making it possible to study the effects of anesthetics on multiple fly samples at the same time.

Figure 2
figure 2

All positions in the Serial Anesthesia Array receive an equivalent concentration of VGA. (A) The Percent Active of male w1118 flies exposed to 0.4% ISO at 1–8 days of age for 10 min in the most upstream (tube 1) and downstream (tube 8) positions (n = 9) (P = 0.77, unpaired equal variance two-tail t-test). (B) The Early Recovery Time of mixed sex w1118 flies exposed to 2% ISO for 1 h at 0–7 days of age in tubes 1–8 (n = 2) (P = 0.36, one-way ANOVA).

Sex but not age affects the PK properties of VGAs

To test whether age at the time of exposure influences recovery from deep anesthesia, we measured Early Recovery Time in mixed sex w1118 flies grouped in 3-day age increments from 0–2 to 26–28 days old. At all ages, recovery was faster from SEVO than ISO, but age did not affect the speed of recovery from either anesthetic (ISO P = 0.98 and SEVO P = 0.89, one-way ANOVA) (Fig. 3A). Hence, as in humans, the PK of these agents is stable in adulthood35. However, sex did affect the recovery from both anesthetics. We found that 1–7 day old w1118 and Canton S (two standard wild type strains) males recovered about twice as fast as females (Fig. 3B and Supplemental Fig. 1).

Figure 3
figure 3

Sex but not age influence the speed of recovery from anesthesia. (A) The Early Recovery Time of mixed sex w1118 flies exposed to anesthesia at the indicated age ranges (n = 5) (ISO P = 0.98 and SEVO P = 0.89, one-way ANOVA). (B) The Early Recovery Time of w1118 male (M) and female (F) flies exposed to anesthesia at 1–8 days old (n = 3) (**P < 0.01, ***P < 0.001, unpaired equal variance two-tail t-test).

Deep anesthesia does not affect lifespan

We tested whether administration of anesthesia to mixed sex w1118 flies at 0–7 days old affected lifespan. After exposures ranging from 0.5 to 5 hr to either 2% ISO or 3.5% SEVO the percentage of surviving flies was determined until all flies had died (Fig. 4A,B and Supplemental Figs 24). Neither the duration of exposure nor the anesthetic agent affected the median or maximum lifespan (Fig. 4C,D). Furthermore, exposure of 1–8 day old male or female w1118 flies to 2% ISO or 3.5% SEVO for 2 hr had no effect on the median or maximum lifespan (Fig. 4E,F and Supplemental Fig. 4). We conclude that, as in rodents36, a single exposure to VGAs does not influence lifespan in healthy flies.

Figure 4
figure 4

Deep anesthesia does not affect lifespan. Survival curves for mixed sex w1118 flies exposed to (A) 2% ISO (264–289 flies) or (B) 3.5% SEVO (264–285 flies) for 1 hr (red) or 5 hr (green) at 0–7 days old. (C) Median and (D) maximum lifespans for exposure times from 0.5 to 5.0 hr (n = 5). (E) Median and (F) maximum lifespans for 1–8 day old males and female flies exposed to 2% ISO or 3.5% SEVO for 2 hr (n = 3) (not significant (ns), unpaired equal variance two-tail t-test).

PK and PD properties of VGA in flies are similar to mammals

Studies comparing the potency of VGAs using the immobility-based minimum alveolar concentration of anesthetic (MAC) concept, which is assumed to reflect the concentration in the central nervous system, yield remarkably consistent results across all mammalian species and all VGAs3. MAC relies on a binary score (purposeful limb movement: yes or no) scaled to deep levels of anesthesia that is insensitive to quantitative nuances. More important, in mammals, MAC readout is determined by drug action in the spinal cord as opposed to the brain37,38. Therefore, applying the classic definition of MAC to invertebrates is problematic due to the difficulty of translating this classic endpoint to organisms with alternative behavioral repertoires39. Hence, researchers have developed a variety of species-specific behavioral endpoints to position experiments in invertebrates into pharmacologically meaningful contexts with studies in mammals. These endpoint definitions have resulted in a wide range of reported EC50s even for a single agent and a single fly strain, e.g. the EC50s for ISO in Canton S was 0.36 ± 0.04 v/v % in our hands and ranged from 0.20% to 0.71% in the literature40,41.

To determine the extent to which clinically important PK and PD properties of VGAs are reproducible in flies, we used the Percent Active assay to compare anesthetic dynamics of ISO and SEVO in w1118 flies. Because sex affects PK properties (Fig. 3B), only males were used for these studies. In 1–7 day old w1118 males, ISO was more potent than SEVO (EC50: 0.41 ± 0.03 v/v % and 0.68 ± 0.05 v/v %, respectively) with a potency ratio (ISO/SEVO) of 0.60 (0.41/0.68) (Fig. 5A and Table 1). Recovery from deep anesthesia was significantly faster for SEVO than for ISO (TtR50: 11.66 ± 0.77 min and 22.94 ± 1.0 min, respectively) with a recovery ratio (ISO/SEVO) of 1.97 (22.94/11.66) (Fig. 5F and Table 1). The potency and recovery differences between ISO and SEVO in flies are consistent with differences observed in humans42.

Figure 5
figure 5

Genetic background modulates the PK and PD properties of VGAs. Panels A-E: Dose-response relationships for ISO and SEVO used to calculate EC50s. The Percent Active was measured in 1–8 day-old male flies at different concentrations (n = 3–5 per genotype and agent). Panels F-J: Time course of recovery from anesthesia (2% ISO or 3.5% SEVO for 1 hr) for the same genotypes as in panels A-E. (n = 3–7 per genotype and agent).

Table 1 Measures of anesthetic potency (EC50) and speed of recovery (TtR50) for isoflurane (ISO) and sevoflurane (SEVO).

A mitochondrial mutation increases the potency of VGAs

One of the potential uses of the Serial Anesthesia Array is to identify heritable genetic variations that affect responses to anesthesia. To explore this possibility, we characterized the behavioral responses of ND23 mutant flies to ISO and SEVO. ND23 is a nuclear gene that encodes a core subunit of Complex I of the mitochondrial electron transport chain. Mutations in subunits of eukaryotic Complex 1, which contains at least 45 distinct subunits, lead to increased sensitivity to VGAs in C. elegans22,23,43, mice24 and humans25; however, the effects of mutations in ND23 (known as T20H4.5 in C. elegans and NDUFS8 in humans) on anesthetic sensitivity have not been studied in any organism. To assess whether the ND2360114 mutation sensitizes flies to anesthetics, we determined the EC50 for ISO and SEVO in 2–4 day old male flies. For both VGAs, the EC50 of ND2360114 flies was lower than that of its control background strain Canton S as well as w1118 (Fig. 6 and Table 1). We conclude that ND23 confers resistance to VGAs.

Figure 6
figure 6

The ND2360114 mutation in Complex I of the mitochondrial electron transport chain increases the potency of ISO and SEVO. The Percent Active of 2–4 day old male Canton S and ND2360114 flies exposed to different concentration of (A) ISO (n = 3) or (B) SEVO (n = 3). (C) EC50s for Canton S and ND2360114 flies, derived from panels A and B, respectively (**P < 0.01, equal variance unpaired two-tail test).

Genomic variation influences the PD and PK properties of VGAs

To explore the pharmacogenomics of VGAs in natural populations we determined the potency and the recovery profiles for ISO and SEVO in two standard laboratory strains (w1118 and Canton S) and four strains derived from a natural population (RAL161, 352, 774, 892). The specific RAL lines were chosen from opposite ends of the mortality spectrum from blunt trauma determined in 179 RAL lines44 from the Drosophila Genetic Reference Panel (DGRP)45: RAL352 and 774 are at the low end, while RAL161 and 892 are at the high end of the mortality spectrum44. In all RAL lines, ISO was more potent than SEVO (Fig. 5, Table 1). However, their potency ratios (ISO EC50/SEVO EC50) varied from 0.32 ± 0.04 (RAL774) to 0.53 ± 0.14 (RAL352) (Table 1). No correlation between the previously determined blunt trauma resilience and sensitivity to VGAs was discernible. ND2360114 was more sensitive to VGAs than all other lines tested: the ISO EC50 of the most sensitive tested RAL line (RAL352) was 35% higher than that of ND2360114 and the EC50 of SEVO was 9% higher. The potency ratios (ISO/SEVO) of all seven lines ranged from 0.32 ± 0.04 (RAL774) to 0.60 ± 0.05 (w1118) (Fig. 7A and Table 1). These results indicate that natural and laboratory populations harbor genetic polymorphisms that differentially modify the behavioral response to chemically closely-related VGAs.

Figure 7
figure 7

Natural Drosophila populations harbor a variety of responses to VGAs. Summary of EC50s (A) and TtR50s (B) from all tested fly lines (Figs 5 and 6) indicates that PD and PK vary unpredictably. (C) The EC50 values of one agent (ISO or SEVO) is a poor predictor of the EC50 of the other (R2 = 0.34). (D) The potency of an agent (ISO or SEVO) does not correlate with its rate of emergence: R2 = 0.069 and 0.001 for ISO and SEVO, respectively. Data are derived from experiments shown in Figs 5 and 6 and Supplemental Fig. 6 (see Table 1 for numerical values).

We also examined the extent to which genetic variation influences recovery from VGAs, a PK parameter not previously examined in invertebrate model organisms. In RAL lines, the ISO TtR50s ranged from 15.37 ± 0.79 min (RAL892) to 37.86 ± 1.26 min (RAL161) and the TtR50s for SEVO ranged from 10.46 ± 0.46 min (RAL892) to 25.71 ± 1.96 min (RAL161) (Figs 5F–J and 7B, and Table 1). As in w1118 flies, recovery from SEVO was faster than from ISO in all tested RAL lines, but the absolute speed of recovery and relative speed of recovery (i.e., ISO TtR50/SEVO TtR50) were different among the four lines (Table 1). These results indicate that both PD and PK profiles (reflected in the EC50 and TtR50, respectively) of VGAs are influenced by genetic background.

Discussion

We have modified existing experimental systems for studying VGAs in flies with the goal of efficiently comparing the effect profiles of VGAs, including PD and PK measures, across different genotypes and experimental interventions. The Serial Anesthesia Array administers identical anesthetic concentrations to multiple samples (Fig. 1A,B) with fast equilibration in all positions (Fig. 1C), assuring equal anesthetic exposure of all samples (Fig. 2). Each position in the array accommodates large numbers of flies providing robust measures for the condition under study. Furthermore, the array offers the ability to simultaneously examine different variables such as age and genotype under the exact same anesthetic dose (Figs 47). Using this system, we obtained robust and reproducible results that demonstrate that genetic background significantly modulates the responses to VGAs in flies.

The relative potencies of VGAs are key factors determining their use in clinical practice. We developed the Percent Active assay because reproducing MAC (the standard assay for potency in mammals46) in invertebrate model organisms is laborious, indirect and operator-dependent47,48,49,50,51. Using the Percent Active assay, we compared VGA potency across multiple fly lines (Figs 57 and Table 1). The resulting EC50s for ISO are comparable to those determined using analogous assays33,34,40, confirming the robustness of the fly model across laboratories. Furthermore, variability in the ISO/SEVO potency and recovery ratios among fly lines demonstrates that natural populations harbor a diversity of genetic polymorphisms that differentially modulate the potency of and the recovery from two prototypical VGAs (Table 1). In this context, it is notable that the potency ratio of the mitochondrial Complex I mutant ND2360114 was very close to that of its background strain Canton S despite substantially higher sensitivity (Fig. 6. and Table 1). This finding indicates that reduced activity of the electron transport chain proportionally affects the sensitivity to ISO and SEVO.

In addition to potency, the rate of recovery from anesthesia is a critical characteristic of all general anesthetics. We are not aware of any studies addressing recovery from VGAs in invertebrates. Therefore, we developed two behavioral assays, Early Recovery Time and Percent Active, to determine the PK of recovery from anesthesia in flies. Both assays demonstrated substantially faster recovery from SEVO compared with ISO replicating the situation in humans (Figs 3, 5, and 7; Supplemental Fig. 6; and Table 1)42. To compare recovery times among strains we use the ISO/SEVO recovery ratio derived from time-to-recovery measurements (Table 1). Its value varied considerably from 1.28 ± 0.13 (Canton S) to 1.97 ± 0.16 (w1118) bracketing the recovery ratio of 1.63 determined in Sprague-Dawley rats52. The range of absolute and relative potencies and recovery rates determined in RAL lines illustrate the degree to which variability in naturally occurring genetic architecture influences anesthetic PK and PD.

Recovery from VGAs is determined by the rate of elimination of the agent from the body, which occurs via the lungs in mammals and by diffusion out of tracheae, which is independent of circulation, in flies. As both ISO and SEVO undergo minimal metabolism in mammals, enzyme polymorphisms (the primary cause of differences in PK for the majority of xenobiotics)19 are unlikely to account for differences in the TtR50 that we observed. To reconcile our comparative findings for ISO and SEVO with standard understanding of VGA PK and PD, we consider the following possibilities. If diffusion out of the body alone determined the speed of recovery, ISO/SEVO TtR50 ratios should be similar among strains (which are all of similar size). However, we found that TtR50 ratios varied considerably (Table 1). Alternatively, if recovery was simply following declining drug concentrations at the target site, the degree of recovery from an agent should lag in a ‘sensitive’ strain (i.e. lower EC50) behind that in a ‘resistant’ strain (i.e. high EC50) because at equal brain concentration of agent a higher fraction of sensitive animals would be anesthetized. If this was the case, the EC50 would inversely correlate with TtR50. However, we found no correlation between the EC50 and the TtR50 (Fig. 7D). Lastly, a difference in brain dynamics may account for the lack of correlation between the EC50 and TtR50. The EC50 captures the transition from awake to anesthetized state, while the TtR50 quantifies the transition from anesthetized to awake state. Experiments with VGAs in flies and in mice demonstrate that the directionality of change in brain states, that is loss vs. recovery of function, occur at different points of a dose-response relationship33. Furthermore, the points differ among VGAs33 and, as suggested by our experiments, may differ among ‘wildtype’ strains. Together, these data indicate that genetic background influences the responsiveness to anesthetics in multiple ways.

Hypomorphic mutations in Complex I of the mitochondrial electron transport chain result in hypersensitivity to VGAs in humans25, mice53, and worms23. To the best of our knowledge, ND2360114 is the first description of a mutation in the electron transport chain affecting a phenotype under anesthesia in flies. ND23 is an ortholog of NDUFS8 in mammals and T20H4.5 in C. elegans. In humans, mutations in NDUFS8 are associated with Leigh syndrome, a progressive neurological degenerative disorder with onset in infancy or childhood54. RNAi knockdown of T20H4.5 renders worms sensitive to halothane-induced immobilization, reducing the EC50 from 3.2% to 2.1%55. For the majority of mutations tested for VGA responsiveness in flies and worms, an understanding of the gene products and regulatory pathways affected is largely incomplete. However, mutations in core subunits of Complex I of the electron transport chain consistently result in varying degrees of hypersensitivity to most VGAs in worms22,43,55 and our data suggest that the same is true in flies. This finding indicates that a common molecular nexus located in mitochondria influences the potency of halothane, ISO, and SEVO and possibly other potent modern inhalational agents. However, mutants with increased anesthetic sensitivity unrelated to mitochondrial proteins have also been described31,56. So, while a research focus on mitochondrial genes is warranted, it is unlikely to completely explain open questions such as why there is a lack of correlation between the EC50 and TtR50.

In summary, genetic variability in the response to VGAs is relevant because phenotypically silent polymorphisms may directly modify not only the dose of anesthetics needed for surgery but also the likelihood of an individual experiencing the deleterious long-term collateral effects of VGAs (acute cognitive disorders, accelerated neurodegeneration, alterations in immune and inflammatory functions). The latter aspect may be more important as it may affect clinically relevant outcomes in surgical populations. So far, genomic modifiers of VGA sensitivity have been largely neglected in clinical studies examining potential long-term sequelae of exposure to VGAs. We expect that newly developed methods for the identification of quantitative trait loci in flies45,57,58, which have already been successfully applied to xenobiotic toxicology59, will contribute to bridging anesthetic phenotype to genotype.

Materials and Methods

Fly lines and culturing

All flies were maintained on standard molasses food containing 30 g Difco granulated agar (Becton-Dickinson, Sparks, MD), 44 g YSC-1 yeast (Sigma, St. Louis, MO), 328 g cornmeal (Lab Scientific, Highlands, NJ), 400 ml unsulphured Grandma’s molasses (Lab Scientific), 3.6 L water, 40 ml propionic acid (Sigma), and tegosept (8 g Methyl 4-hydroxybenzoate in 75 ml 95% ethanol) (Sigma). DGRP strains were obtained from the Bloomington Stock Center. The ND2360114 line is an EMS mutant line from the Ganetzky lab temperature-sensitive paralytic collection. Mix sex fly samples contained males and females in a 1:1 ratio (Supplemental Fig. 5). w1118 and DGRP flies were maintained at 25 °C. In Fig. 6, Canton S and ND2360114 flies were maintained at 25 °C and then switched to 29 °C at 0–2 days post-eclosion for the remainder of the experiment. In Supplemental Figs 1 and 6, Canton S flies were maintained at 25 °C.

Serial Anesthesia Array assembly, operation, and characterization

The Serial Anesthesia Array was constructed using Falcon 50 mL conical tubes (Fisher Scientific, Waltham, MA), polystyrene serological pipettes (Fisher Scientific), Tygon tubing AAC00022 5/16″ ID × 7/16″ OD (Saint-Gobain North America, Malvern, PA), a Bel-Art paddle style flow indicator model 19937-0003 (Cole-Parmer, Vernon Hills, IL), and calibrated, agent-specific Tec 7 vaporizers (Datex-Ohmeda, Inc., Madison, WI). ISO and SEVO were obtained from Piramal Enterprises Ltd. (Maharashtra, India). Additional details about assembly and operation of the array are provided in Fig. 1A,B and the Results section. A GOW-MAC Series 580 flame ionization gas chromatograph (GOW-MAC Instrument Co., Bethlehem, PA) calibrated with 1% ISO (Calibration cylinder, Air Liquide Healthcare, Madison, WI) was used to measure ISO concentrations. The time constant (τ) for ISO was calculated using the equation CArray = CAF (1-e−T/τ), where CArray is the anesthetic concentration in the array, CAF is the anesthetic concentration flowing into the array, T is sampling time after initiation of air flow, and τ is the time constant [τ = (capacity of the array in mL)/(flow rate mL/min)]. Using this equation and gas chromatograph measurements yielded the experimental time constant of the array (Fig. 1C).

Behavioral and lifespan assays

Effects of anesthetics on flies were quantified using customized, negative geotaxis-based behavioral Early Recovery Time and Percent Active assays, described in the Results section. To determine median and maximum lifespans after exposure to 2% ISO or 3.5% SEVO for various times, flies were cultured on molasses food at 25 °C and transferred to fresh food every 3–4 days. The number of dead flies was recorded daily (except weekends) until all flies had died. Additional details are provided in Fig. 4 and Supplemental Figs 24.

Data analysis and statistics

We analyzed data using GraphPad Prism 6 software (La Jolla, CA) and calculated statistical significance between two data distributions using the unpaired equal-variance two-tail t-test. We used ANOVA for three or more data points. Error bars in all figures represent the standard error of the mean. Standard deviations are presented in Table 1.