Abstract
Using recently-developed THz emitters constructed from single crystals of the high-Tc superconductor Bi2Sr2CaCu2O8+δ, we performed three prototype tests of the devices to demonstrate their unique characteristic properties for various practical applications. The first is a compact and simple transmission type of THz imaging system using a Stirling cryocooler. The second is a high-resolution Michelson interferometer used as a phase-sensitive reflection-type imaging system. The third is a system with precise temperature control to measure the liquid absorption coefficient. The detailed characteristics of these systems are discussed.
Similar content being viewed by others
Introduction
Terahertz (THz = 1012 c/s) electromagnetic waves (EMWs) have various unique features that open new possibilities in the research areas of science and technology that enable various important applications, such as non-destructive evaluations, various imaging techniques, high-speed communications, security, medical diagnoses, biosciences, and biotechnologies, etc.1,2. From both technical and practical points of view, THz imaging may be the most widely demanded application, since THz EMWs can penetrate through many dry and nonmetallic materials as microwaves do, but their spatial resolution is better than microwaves due to their shorter wavelengths3,4,5,6. Another important potential field of applications may be the spectroscopic investigation and identification of particular molecules or polymers, which have definite fingerprint spectra due to molecular vibrations or rotations7,8,9.
Among the many imaging and sensing systems using THz EMWs that have been reported to date are a three-dimensional computed tomography (3D CT) imaging system10, a time-of-flight imaging system that can obtain depth information11, an imaging system below the diffraction limit using near-field lighting12, a THz chemical microscope13, and a high-resolution spectrometer using a THz-comb14. Systems based on THz time domain spectroscopy (THz-TDS) using pulsed-wave sources have made especially significant progress, and some systems have already been commercialized by Advanced Photonix Inc, Tera View, ADVANTEST Corp., etc. On the other hand, applications using continuous and monochromatic THz waves can be used for simpler and higher-speed imaging, imaging at a stand-off distance, higher-resolution spectroscopy, and coded information technology, etc. In order to put these applications to use, development of a compact, convenient, tunable, and powerful device is urgently needed.
In present THz imaging, backward-wave oscillators (BWOs) have been useful and very convenient THz sources with moderate power (mW) and frequencies ranging from a few 100 GHz to 1.5 THz4. Because BWOs employ vacuum electron tubes operating in a moderate magnetic field at room temperature, they have the advantage of emissions that are tunable by about ~100 GHz about their central frequency. On the other hand, BWOs have the disadvantages of their large masses (~50 kg), short operating lives (several hundreds of hours), power drifts over time, and rather poor reproducibility (≃1%), etc.15.
The unique (sub-) THz source based on a single-crystalline mesa structure of the high transition-temperature Tc superconductor Bi2Sr2CaCu2O8+δ (Bi2212) was first reported in 200716, and its subsequent development has proceeded rapidly17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46. Output radiation powers of a few tens of μW have been consistently achieved from single conventional mesas37,43,44, and of about 600 μW was reported from a synchronized conventional three-mesa array45, and the radiation frequency could be varied almost continuously between 0.3 and 2.4 THz from a stand-alone mesa sandwich device46. In many experiments, the radiation frequency was measured using interferometer-based spectrometers18,23–25. Since optical path differences in these interferometers determine the spectral resolution of the spectrometers, it is commonly than 7.5 GHz, which is much larger than the spectral linewidth of the THz radiation from IJJ-THz emitters35.
The THz radiation from Bi2212 mesa structures discussed here is completely different from that of conventional semiconducting or optical devices in principle, and it has the characteristic features of continuous, stable, and monochromatic EMWs. In Bi2212 with the high superconducting Tc ~ 90 K, a periodic array of alternating superconducting CuO2 and insulating Bi2O2 double layers is stacked along the c-axis (perpendicular to the CuO2 plane) on an atomic scale. Each insulating layer behaves as an intrinsic Josephson junction (IJJ), which weakly couples the adjacent superconducting layers. Therefore, the mesa structure of Bi2212 consists of IJJs regularly stack of 653 junctions per 1 μm stacked along the c-axis direction47. The fundamental mechanism of the THz EMW emission from the IJJ emitters was previously revealed to be the ac-Josephson effect48, with emission frequencies f satisfying f = fJ = (2e/h) (V/N), where e and h are the electronic charge and Planck’s constant, respectively, V is the applied dc voltage, and N in the number of active IJJs in the mesa. According to this relation, a dc voltage of 1 mV applied to each IJJ gives rise to an ac current with fJ satisfying the 2010 CODATA recommended value of 483.597870(11) GHz, Since V can be varied continuously in some ranges of the dc current-voltage (I-V) characteristic curve, the f can also be varied continuously. Therefore, tunable THz EMWs in principle can be generated by adjusting V.
However, the insulating layers in the mesa cause it to behave as an electromagnetic cavity, which allows for internal standing THz EMWs. When fJ matches a cavity resonance frequency fcav of the particular mesa shape, the output power is significantly enhanced. For a rectangular mesa of width w, the observed fcav = c0/(2nw), where c0 is the light velocity in vacuum, and n ~ 4.2 is the refractive index of Bi2212. Actually, for conventional Bi2212 mesas, the cavity quality factor Q ~ 10 is not as high as for quantum cascade lasers or solid state lasers, for example, so that f can be widely tunable35,36,43.
Here, we demonstrate the performances of measurement systems that were not described previously49,50,51, detailing the characteristic features of the continuous monochromatic radiation from the IJJ-THz emitters. The first one is a compact and convenient THz imaging system cooled down to 40 K only by a Stirling cryocooler. The second one is a home-built Michelson type of interferometer constructed by modifying a reflection type of IJJ-THz emitter imaging system to develop a phase-sensitive imaging system. Finally, an IJJ-THz emitter device to measure the absorption coefficient of a liquid sample for temperatures between 0 °C and 70 °C is described in detail.
Results and Discussion
The IJJ-THz emitting device is made from a piece of a single crystal of Bi2212 grown by a traveling-solvent floating-zone method. The crystal is annealed overnight at 550 °C in air and quenched to obtain a sharper superconducting transition behavior and the optimum doping level. The crystal is cut into a few mm in lateral dimensions, then is cleaved to a few μm in thickness. The cleaved surface is immediately deposited with Ag and then Au layers 50–100 nm thick. A rectangular stand-alone mesa is made by Ar milling, mounted between two sapphire plates with deposited gold electrodes, and is placed in a Cu holder and sandwiched mechanically. More details of the stand-alone mesa sandwich fabrication are given in ref. 52.
Compact and simple imaging system using a Stirling cryocooler down to 40 K
Measurement setup
Figure 1(a) shows a photograph of the experimental setup used for a compact and convenient imaging system cooled by a Stirling engine operated by a 45 V dc battery with a cooling power of better than 16 W at 77 K and an input power of 240 W, whose cold tip is cooled down to 35 K within a stability of 0.1 K. A corresponding schematic diagram of the experimental setup is shown in Fig. 1(b). The IJJ-THz emitter is fixed mechanically to the cold tip and can be cooled to 40 K within 30 minutes. The THz EMWs generated by the IJJ-emitter are collected and transformed into a parallel beam by the first lens, L1, then it is focused onto the sample by the second lens, L2, with a focal length of 60 mm. These two lenses have the same diameter of 52 mm. As seen in Fig. 1(a,b), the total length between the cryocooler and the sample is about 20 cm. Except for the detector, the total mass of this system is less than 4 kg.
The transmitted THz beam is detected by a high-speed InSb hot-electron (HE) bolometer, and the detection power is monitored by a lock-in amplifier with a time constant of 3 ms. In order to acquire two-dimensional (2D) images, the sample set at the L2 focal point was scanned in the x (horizontal) and y (vertical) directions at a variable speed below 130 mm/s with a 2D(x, y) scanning stage. The analog signal from the lock-in amplifier is converted to a digital signal with a resolution of 16 bits by an analog-to-digital (A/D) converter. The motion of the stage can be controlled by a homemade LabVIEW (National Instruments Co.) program. The actual signal processing of our systems is performed as follows: In order to generate the pulse-modulated (PM) THz wave, the IJJ-THz emitter was modulated with an ac square-wave voltage of amplitude ~80 mV and frequency 10 kHz onto the dc bias voltage with a function generator, where 10 kHz is the frequency of the optimal noise performance of InSb HE bolometer. We note that this electronic modulation detection method is superior to that of an optical chopper modulation, since the far-infrared background noise from the ambient spurious radiation can be completely rejected. The motivation for this detection method in a transmission-type imaging system was described previously49.
For this measurement, a stand-alone mesa sandwich IJJ-THz emitter of dimensions 58 × 350 × 4.7 μm3 was used. Although this device is comparatively thick, as seen in Fig. 1(c), a large bias V can be applied to it without I-V characteristic back-bending, which led to negative dynamical resistance in earlier conventional mesas. The present stand-alone mesa sandwich structures have high heat-exhaust efficiency due to the surrounding sapphire and copper plates with high thermal conductivity. As a result, this stand-alone type of IJJ-THz emitter can generate radiation from 0.3 THz to 2.4 THz by changing the bias point and the bath temperature44,46,52. We note that the thicker mesa has more layers for THz radiation, so that it is in general expected to have stronger THz radiation. However, the thicker mesa may have more heat generated and could suffer from increased self-heating. It is empirically known that the optimal mesa thickness is a few μm. The reproducibility of the stand-alone mesa has recently improved greatly to 20–25%.
An example of the I-V characteristics of the emitter at the bath temperature 54 K is shown in Fig. 1(c), where the output power detected by the HE bolometer with a modulation amplitude of Vmod = 80 mV at the frequency of fmod = 10 kHz is also plotted as a function of V. This emitter generates 0.59 THz wave radiation at the bias point encircled by the solid curve, which was measured by using the interference pattern technique reported previously49. The detected power is estimated to be about 5.1 nW from the responsivity of the InSb HE bolometer of 3.3 mV/nW during the measurements.
Basic properties and demonstration
In an imaging system with a raster scan method, the beam waist (the minimum beam diameter at the focal point) and the depth of focus are important parameters for the optical system performance. The beam waist can greatly affect the spatial resolution of the images and the depth of focus indicates the tolerance of the spatial resolution to the optical axis direction changes.
In order to estimate these two parameters in our THz imaging system, we scanned an edge of a 1 mm thick metallic plate by changing the position of the optical z axis direction. The measured data were analyzed based on the knife-edge method. Assuming a Gaussian distribution of the beam’s intensity, the transmitted intensities I(x) obtained around the horizontal x-position can be fitted by the following equation:
where I0 is the maximum intensity of the beam, x is the position of the knife edge, xc is the distribution center, d is the full width at half maximum (FWHM) of the Gaussian distribution, and erf(x) is the error function.
Here, the beam diameter d is a parameter in Eq. (1). Figure 2(a) shows measured values of d at many positions in the z direction. The inset shows an example of the measured result at the focal point (z = 0). The fitting curve and its first derivative are shown in the inset in Fig. 2(a). The I(x) observed is fitted very well by Eq. (1). The beam waist d0 of our system is estimated to be 1.36 mm. The depth of focus Δz, defined as the range where the beam diameter is smaller than , can therefore be estimated to be about 18 mm.
Δz can also be calculated by the following relation as twice the Rayleigh range:
where d0 is the beam waist and λ is the wavelength of the EMWs. In our case, the value of the fitting d0 is 16.5 mm, which is consistent with its measured value of ~18 mm.
First derivatives of the fitting curve at each position are shown in Fig. 2(b) by the contour color plot. This graph displays the spatial distribution of the beam intensity, which drastically broadens outside of the depth of focus. This means that if the sample’s thickness or the optical axial position is larger than this range, the spatial resolution is quickly lost.
Next, in order to demonstrate the performance of the imaging system, we measured an IC card and the result is shown in Fig. 3, where the increment of the translation of the sample is 0.5 mm in Fig. 3(a). In Fig. 3(b), the region encircled by a doted box in Fig. 3(a) is displayed by remeasuring with a finner step of the increment of 0.2 mm.
As seen in both images, the circuit structures embedded inside the integrated-circuit (IC) card can be clearly resolved. Especially, the comb-shaped electric circuit structure with an interval of about 1.3 mm inside the plastic body can be clearly seen (see Fig. 3(b)). As a consequence, this THz imaging system can at least reach the spatial resolution of 1.3 mm. Here, we compare the image shown in Fig. 3 with the one given in Fig. 10 of ref. 4, which reported the performance of an imaging system using a BWO. The image resolution of the BWO system is better than that of our system because the beam waist of the BWO system is half that of our system, and the output power of the BWO (~15 mW at this frequency range) is much stronger than that of the IJJ-THz emitter. On the other hand the depth of focus of our system is longer than that of the BWO system. As an additional advantage of our system, THz imaging over a wide frequency range will be available in the near future, according to recent reports44,46.
Construction of a high-resolution spectrometer based on a Michelson type of interferometer
A Michelson type of interferometer, which allows one to measure the THz frequency spectrum of the radiation with sufficiently high resolution, can easily be constructed by modifying a reflection type of imaging system. Figure 4(a) shows the diagram of the optical system. A Si-wafer is used as a beam splitter as was done previously50. For the present measurements, the mirror was scanned over 18 cm (an optical path difference L = 36 cm) in 20 μm steps and a scanning speed of 0.2 mm/s (15 min/scan). As a test operation, the THz wave emitted from the 80 × 400 × 2.4 μm3 IJJ-THz emitter was used at the bath temperature of 45 K.
According to the principle of operation of this type of interferometer, the spectral resolution Δf determined from Δf = c/L is estimated to be 0.83 GHz. The spectrum obtained from the IJJ-THz emitter is displayed in Fig. 4(b) after performing a fast Fourier transform (FFT) of the interferogram, part of which is shown in the inset of Fig. 4(b).
In Fig. 4(b), it is noted that in addition to the main peak in the spectrum, two other small peaks can be seen near to 0.443 THz and 0.455 THz, as indicated by the vertical arrows. These peaks could not be resolved in previous measurements performed with a commercial spectrometer with a maximum resolution of 7.5 GHz, and suggest that the emission spectrum from the IJJ-THz emitter may not be monochromatic in this particular retrapping bias point region on the irreversible I-V curve, because the emission from this region is well known to be unstable due to the nonlinear ac-Josephson effect, resulting in the small splitting of the emission line as seen in higher resolution measurements. This is evidenced by wider spectral line widths previously observed for THz EMWs emissions in the retrapping region of the I-V characteristics35. Further spectroscopic studies with higher resolution are needed to better understand the IJJ-radiation.
By fitting the main peak with a Lorentzian function, the central frequency and the full-width at half-maximum are estimated to be 0.453 THz and 1.07 GHz, respectively. This spectral line width is close to the resolution limit of this system and similar to that of the Martin-Puplett type of interferometer used in ref. 25. Note that this value of the line width is much shorter and certainly is beyond the resolution limit of the commercial FT-IR spectrometer (FARIS-1, JASCO).
From the above, we conclude that a high-resolution FT-IR spectrometer based upon a Michelson type of interferometer was constructed successfully. Combining this interferometer with our imaging systems, a continuous-wave THz phase imaging system53 is now under construction.
Measurement of the absorption coefficient of a liquid
THz EMWs are known to be strongly absorbed by liquid water in the wide frequency range from the microwave to the far infrared regions54. In aqueous solution, it is known that solute molecules and hydrated water show an interesting interplay of relaxational responses in the MHz to GHz spectral region55. However, because of the complicated behavior consisting of three relaxational responses of solute molecules, hydrated water, and bulk water, it is difficult to extract information on hydrated water from the low-frequency dielectric responses. On the other hand, the dielectric loss is simply reduced according to the amount of hydrated water in the THz region. Therefore, the hydrated state of a liquid sample can be evaluated by measuring the absorption coefficient of the sample.
A technique for measuring an absorption coefficient of a liquid sample was developed previously by using a wedge-shaped quartz cell (WSQ-cell)4,49,56,57. In this method, the WSQ-cell is filled by the liquid and scanned linearly from the thinner end to the thicker end, and the transmitted THz intensity is measured as a function of the scanned length. The measured data is fitted by the equation I = I0 exp(−αt), where I is the intensity of the transmitted THz EMWs, I0 is the power of the THz EMWs, α is the absorption coefficient and t is the thickness of the sample. This WSQ-cell enables one to obtain the absorption coefficient very easily and precisely, even for a sample with a high absorptivity, because only a line scan is needed for the measurement, and parameters other than α, such as the absorption of the quartz plates, are usually negligible.
Figure 5 is a schematic diagram of the variable-temperature WSQ-cell. Two quartz plates are fixed by screws into a wedge shape inside a copper box. The copper box has a slit through which the THz EMWs can pass. In order to control the sample temperature, four Peltier devices are set between a water-cooled aluminum box and a side of the copper box, as shown in Fig. 5.
A temperature controller is used to control the Peltier devices. In order to monitor the sample temperature, a platinum resistance thermometer was attached to a side wall of the copper box and connected to the temperature controller. The absorption coefficient of the measured liquid is calculated and plotted as a function of the sample temperature by a homemade LabVIEW program. This system can control the temperature T between 0 and 70 °C with an accuracy of ±0.5 °C.
To demonstrate the utility of this system, the temperature dependence of the absorption coefficient of pure water with a resistivity of more than 1 MΩ · cm at 25 °C (Kyoei Pharmaceutical Co., Ltd.) was measured. Figure 6 displays our results and compares them with other data obtained previously by a THz-TDS system (see ref. 58). A 60 × 400 × 1.6 μm3 IJJ-THz emitter that generates 0.497 THz radiation is used for the present measurements. The measurements can be made within about 16 s per scan at a fixed T to obtain α(T). The measured α(T) agrees very well with other published data, as shown in Fig. 6.
The error bars of the measured α-values are ±0.6 cm−1 at 0 °C and ±3.9 cm−1 at 70 °C. These values provide the most accurate measurements of the absorption coefficient of water in this frequency region because the signal-to-noise ratio is much higher than for other techniques.
Summary
We presented here three THz measurement systems for applications using a stand-alone mesa sandwich IJJ-THz emitter. First, a compact THz imaging system using a Stirling cryocooler with a measured beam waist and depth of focus was made, and to demonstrate its utility, it was used to obtain the transmission THz image of an IC card.
Second, a Michelson type of interferometer based on a reflection type of THz imaging system was shown. The interferogram was clearly observed, and its Fourier transform was made to obtain it frequency spectrum showed that device has a spectral resolution of 0.83 GHz which is much better than the resolution of the commercial FT-IR spectrometer (FARIS-1) used for previous works (~7.5 GHz).
Finally, we described a system to measure the absorption coefficient of a liquid sample at a variable temperature T between 0 and 70 °C within an accuracy of ±0.5 °C. The absorption coefficient α(T) of pure water was obtained with high accuracy, and is in good agreement with previous measurements.
Methods
In the systems presented here, we used the following components: a Stirling cooler engine (CryoTel GT, Sunpower Inc.), the lens L2 shown in Fig. 1 (Terahertz-Super Lens “Tsurupica”, PAX Co.), a InSb HE bolometer(QFI/2BI, QMC Instruments Ltd.), a lock-in amplifier (Model 7265, EG & G instruments Ltd.), a 2D scanning stage (SGAMH26-200, Sigma Koki Co.), and A/D converter (PXI-5922, National Instruments), a function generator (33220A, Agilent), and a temperature controller (OCE-TCR24600WL, Ohm Electric Inc.) was used to control the Peltier devices.
Additional Information
How to cite this article: Nakade, K. et al. Applications using high-Tc superconducting terahertz emitters. Sci. Rep. 6, 23178; doi: 10.1038/srep23178 (2016).
References
Ferguson, B. & Zhang, X.-C. Materials for terahertz science and technology. Nat. Mater. 1, 26–33 (2002).
Tonouchi, M. Cutting-edge terahertz technology. Nat. Photonics 1, 97–105 (2007).
Hu, B. & Nuss, M. Imaging with terahertz waves. Opt. Lett. 20, 1716–1718 (1995).
Dobroiu, A. et al. Terahertz imaging system based on a backward-wave oscillator. Appl. Opt. 43, 5637–5646 (2004).
Chan, W. L., Deibel, J. & Mittleman, D. M. Imaging with terahertz radiation. Rep. Prog. Phys. 70, 1325 (2007).
Jansen, C. et al. Terahertz imaging: Applications and perspectives. Appl. Opt. 49, E48–E57 (2010).
Kawase, K., Ogawa, Y., Watanabe, Y. & Inoue, H. Non-destructive terahertz imaging of illicit drugs using spectral fingerprints. Opt. Express 11, 2549–2554 (2003).
Chen, J., Chen, Y., Zhao, H., Bastiaans, G. J. & Zhang, X.-C. Absorption coefficients of selected explosives and related compounds in the range of 0.1–2.8 THz. Opt. Express 15, 12060–12067 (2007).
Ho, L., Pepper, M. & Taday, P. Terahertz spectroscopy: Signatures and fingerprints. Nat. Photonics 2, 541 (2008).
Mittleman, D. M., Hunsche, S., Boivin, L. & Nuss, M. C. T-ray tomography. Opt. Lett. 22, 904–906 (1997).
Zhong, H. et al. Nondestructive defect identification with terahertz time-of-flight tomography. Sensors Journal, IEEE 5, 203–208 (2005).
Hunsche, S., Koch, M., Brener, I. & Nuss, M. THz near-field imaging. Opt. Commun. 150, 22–26 (1998).
Kiwa, T. et al. Chemical sensing plate with a laser-terahertz monitoring system. Appl. Opt. 47, 3324–3327 (2008).
Hsieh, Y.-D. et al. Spectrally interleaved, comb-mode-resolved spectroscopy using swept dual terahertz combs. Sci. Rep. 4, 3816 (2014).
Kontorowicz, G. & Palluel, P. Backward Wave Oscillators in Infrared and Millimeter Waves Vol. 1 Ch. 4 185 Academic Press, Inc. (1979).
Ozyuzer, L. et al. Emission of coherent THz radiation from superconductors. Science 318, 1291–1293 (2007).
Welp, U., Kadowaki, K. & Kleiner, R. Superconducting emitters of THz radiation. Nat. Photonics 7, 702–710 (2013).
Kadowaki, K. et al. Direct observation of tetrahertz electromagnetic waves emitted from intrinsic Josephson junctions in single crystalline Bi2Sr2CaCu2O8 +δ . Physica C: Superconductivity 468, 634–639 (2008).
Bulaevskii, L. & Koshelev, A. Radiation due to Josephson oscillations in layered superconductors. Phys. Rev. Lett. 99, 057002 (2007).
Kashiwagi, T. et al. High temperature superconductor terahertz emitters: Fundamental physics and its applications. Jpn. J. Appl. Phys. 51, 010113 (2012).
Tsujimoto, M. et al. Broadly tunable subterahertz emission from internal branches of the current-voltage characteristics of superconducting Bi2Sr2CaCu2O8+δ single crystals. Phys. Rev. Lett. 108, 107006 (2012).
Minami, H., Kakeya, I., Yamaguchi, H., Yamamoto, T. & Kadowaki, K. Characteristics of terahertz radiation emitted from the intrinsic Josephson junctions in high-T c superconductor Bi2Sr2CaCu2O8 +δ . Appl. Phys. Lett. 95, 232511 (2009).
Yuan, J. et al. Terahertz emission from Bi2Sr2CaCu2O8+δ intrinsic Josephson junction stacks with all-superconducting electrodes. Supercond. Sci. Technol. 25, 075015 (2012).
Turkoglu, F. et al. Interferometer measurements of terahertz waves from Bi2Sr2CaCu2O8+δ mesas. Supercond. Sci. Technol. 25, 125004 (2012).
Kakeya, I., Hirayama, N., Nakagawa, T., Omukai, Y. & Suzuki, M. Temperature and current dependencies of terahertz emission from stacks of intrinsic Josephson junctions with thin electrodes revealed by a high-resolution FT-IR spectrometer. Physica C: Superconductivity 491, 11–15 (2013).
Minami, H. et al. Local SiC photoluminescence evidence of hot spot formation and sub-THz coherent emission from a rectangular Bi2Sr2CaCu2O8 +δ . Phys. Rev. B 89, 054503 (2014).
Wang, H. et al. Hot spots and waves in Bi2Sr2CaCu2O8+δ intrinsic Josephson junction stacks: a study by low temperature scanning laser microscopy. Phys. Rev. Lett. 102, 017006 (2009).
Benseman, T. et al. Direct imaging of hot spots in Bi2Sr2CaCu2O8+δ mesa terahertz sources. J. Appl. Phys. 113, 133902 (2013).
Gross, B. et al. Hot-spot formation in stacks of intrinsic Josephson junctions in Bi2Sr2CaCu2O8 +δ . Phys. Rev. B 86, 094524 (2012).
Kakeya, I., Omukai, Y., Yamamoto, T., Kadowaki, K. & Suzuki, M. Effect of thermal inhomogeneity for terahertz radiation from intrinsic Josephson junction stacks of Bi2Sr2CaCu2O8 +δ . Appl. Phys. Lett. 100, 242603 (2012).
Wang, H. B. et al. Coherent terahertz emission of intrinsic Josephson junction stacks in the hot spot regime. Phys. Rev. Lett. 105, 057002 (2010).
Tsujimoto, M. et al. Geometrical resonance conditions for thz radiation from the intrinsic Josephson junctions in Bi2Sr2CaCu2O8 +δ . Phys. Rev. Lett. 105, 037005 (2010).
Guénon, S. et al. Interaction of hot spots and terahertz waves in Bi2Sr2CaCu2O8+δ intrinsic Josephson junction stacks of various geometry. Phys. Rev. B 82, 214506 (2010).
Tsujimoto, M. et al. Dynamic control of temperature distributions in stacks of intrinsic Josephson junctions in Bi2Sr2CaCu2O8+δ for intense terahertz radiation. Phys. Rev. Applied 2, 044016 (2014).
Li, M. et al. Linewidth dependence of coherent terahertz emission from Bi2Sr2CaCu2O8+δ intrinsic Josephson junction stacks in the hot-spot regime. Phys. Rev. B 86, 060505 (2012).
Benseman, T. et al. Tunable terahertz emission from Bi2Sr2CaCu2O8+δ mesa devices. Phys. Rev. B 84, 064523 (2011).
Sekimoto, S. et al. Continuous 30 μw terahertz source by a high-T c superconductor mesa structure. Appl. Phys. Lett. 103, 182601 (2013).
Tachiki, M., Fukuya, S. & Koyama, T. Mechanism of terahertz electromagnetic wave emission from intrinsic Josephson junctions. Phys. Rev. Lett. 102, 127002 (2009).
Lin, S. & Hu, X. Possible dynamic states in inductively coupled intrinsic Josephson junctions of layered high-t c superconductors. Phys. Rev. Lett. 100, 247006 (2008).
Klemm, R. A. & Kadowaki, K. Output from a Josephson stimulated terahertz amplified radiation emitter. J. Phys.: Condens. Matter 22, 375701 (2010).
Asai, H., Tachiki, M. & Kadowaki, K. Three-dimensional numerical analysis of terahertz radiation emitted from intrinsic Josephson junctions with hot spots. Phys. Rev. B 85, 064521 (2012).
Ji, M. et al. Bi2Sr2CaCu2O8 intrinsic Josephson junction stacks with improved cooling: Coherent emission above 1 THz. Appl. Phys. Lett. 105, 122602 (2014).
Kitamura, T. et al. Broadly tunable, high-power terahertz radiation up to 73 K from a stand-alone Bi2Sr2CaCu2O8+δ mesa. Appl. Phys. Lett. 105, 202603 (2014).
Kashiwagi, T. et al. Generation of electromagnetic waves from 0.3 to 1.6 terahertz with a high-T c superconducting Bi2Sr2CaCu2O8+δ intrinsic Josephson junction emitter. Appl. Phys. Lett. 106, 092601 (2015).
Benseman, T. et al. Powerful terahertz emission from Bi2Sr2CaCu2O8+δ mesa arrays. Appl. Phys. Lett. 103, 022602 (2013).
Kashiwagi, T. et al. A high-T c intrinsic Josephson junction emitter tunable from 0.5 to 2.4 terahertz. Appl. Phys. Lett. 107, 082601 (2015).
Kleiner, R., Steinmeyer, F., Kunkel, G. & Müller, P. Intrinsic Josephson effects in Bi2Sr2CaCu2O8+δ single crystals. Phys. Rev. Lett. 68, 2394 (1992).
Josephson, B. Possible new effects in superconductive tunnelling. Phys. Lett. 1, 251–253 (1962).
Tsujimoto, M. et al. Terahertz imaging system using high-T c superconducting oscillation devices. J. Appl. Phys. 111 (2012).
Kashiwagi, T. et al. Reflection type of terahertz imaging system using a high-T c superconducting oscillator. Appl. Phys. Lett. 104, 022601 (2014).
Kashiwagi, T. et al. Computed tomography image using sub-terahertz waves generated from a high-T c superconducting intrinsic Josephson junction oscillator. Appl. Phys. Lett. 104, 082603 (2014).
Kashiwagi, T. et al. Efficient fabrication of intrinsic-Josephson-junction terahertz oscillators with greatly reduced self-heating effects. Phys. Rev. Appl. 4, 054018 (2015).
Wang, Y. et al. Continuous-wave terahertz phase imaging using a far-infrared laser interferometer. Appl. Opt. 50, 6452–6460 (2011).
Yada, H., Nagai, M. & Tanaka, K. Origin of the fast relaxation component of water and heavy water revealed by terahertz time-domain attenuated total reflection spectroscopy. Chem. Phys. Lett. 464, 166–170 (2008).
Arikawa, T., Nagai, M. & Tanaka, K. Characterizing hydration state in solution using terahertz time-domain attenuated total reflection spectroscopy. Chem. Phys. Lett. 457, 12–17 (2008).
Tyler, I., Taylor, G. & Querry, M. R. Thin-wedge-shaped cell for highly absorbent liquids. Appl. Opt. 17, 960–963 (1978).
Wieliczka, D. M., Weng, S. & Querry, M. R. Wedge shaped cell for highly absorbent liquids: Infrared optical constants of water. Appl. Opt. 28, 1714–1719 (1989).
Rønne, C. et al. Investigation of the temperature dependence of dielectric relaxation in liquid water by THz reflection spectroscopy and molecular dynamics simulation. J. Chem. Phys. 107, 5319–5331 (1997).
Acknowledgements
K.K., T.K. and H.M. are supported by the JSPS KAKENHI Grant-in-Aid for Scientific Research (A) (Grant No. 15H01996), and T.K. is also supported by the JSPS KAKENHI Grant-in-Aid for Scientific Research (C) (Grant No. 15K20897). K.N. thanks the staff members of the Central Workshop at the University of Tsukuba for machining support.
Author information
Authors and Affiliations
Contributions
K.N., T.K. and Y.S. designed the THz imaging system and a Michelson type of interferometer, and carried out the experiments. K.N. and H.M. designed and carried out the measurements of absorption coefficients. K.K. supervised the project. R.A.K. gave his critical comments and advice, and checked the English. T.Y. produced the single crystal of Bi2212. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Nakade, K., Kashiwagi, T., Saiwai, Y. et al. Applications using high-Tc superconducting terahertz emitters. Sci Rep 6, 23178 (2016). https://doi.org/10.1038/srep23178
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/srep23178
This article is cited by
-
Erratum to: Terahertz spectroscopy of high temperature superconductors and their photonic applications
Journal of the Korean Physical Society (2022)
-
Terahertz spectroscopy of high temperature superconductors and their photonic applications
Journal of the Korean Physical Society (2022)
-
IV-characteristics and power of emission from stacks of long Josephson junctions with Gaussian spread of critical currents
Applied Nanoscience (2020)
-
Hidden Object Detection and Recognition in Passive Terahertz and Mid-wavelength Infrared
Journal of Infrared, Millimeter, and Terahertz Waves (2019)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.