Abstract
Magnesium oxide (MgO) sensing membranes in pH-sensitive electrolyte-insulator-semiconductor structures were fabricated on silicon substrate. To optimize the sensing capability of the membrane, CF4 plasma was incorporated to improve the material quality of MgO films. Multiple material analyses including FESEM, XRD, AFM, and SIMS indicate that plasma treatment might enhance the crystallization and increase the grain size. Therefore, the sensing behaviors in terms of sensitivity, linearity, hysteresis effects, and drift rates might be improved. MgO-based EIS membranes with CF4 plasma treatment show promise for future industrial biosensing applications.
Similar content being viewed by others
Introduction
Intensive studies have been conducted to the development of ion-sensitive field-effect transistors (ISFETs) or electrolyte-insulator-semiconductor (EIS) sensors within the last forty decades. Since the first ISFET was invented by Bergveld in 19701 and the first pH-ISFET was proposed by Caras and Janato2, various kinds of ISFET-based biochemical sensors have been evolved. With the advantages of low cost, fast response, and small size, the ISFET-based devices are promising for future clinical biotests or environmental hazard monitoring3. However, for the sensing material is one of the key factors in the device sensing applications, there are still some material related problems that may cloud future development of the ISFET-based sensors such as dangling bonds on the sensing membrane and insufficient isolation between the chemical solution/device interface4. Since the sensing membrance in the ISFET-based devices plays a major role in the sensing performance, new materials, alternative processes or unconventional treatment have been tried to boost the sensing behaviors. Among novel materials, Nb2O55, CeO26, and Sm2O37 have been demonstrated as good sensing film materials and the experimental data approve that the ISFET-based sensors incorporating some materials can achieve excellent sensing capability. Futhermore, on the other hand, zooming in the chemical solution/membrance interface can study the subtle membrance material morphologies and characteristics of different materials and gain insight to the interactions between the ions and the surface of various kinds of materials8. Not only can the research create high-performance biosensors but help researchers to explore the surface chemical reactions of these novel materials for future applications so as to kill two birds (biosensors creation and material surface characterizations) with one stone9. The sensing membrane material is made of metal oxides, which represent an important group of materials exhibiting a wide range of material properties from insulators to semiconductors and conductors10. In this research, we select magnesium oxide (MgO), which has been used as ferroelectric materials11, building materials12, 13, optical materials14, and medicine for versatile applications, as the sensing membrane material. MgO with a high bandgap of 7.8 eV and perovskite structures15 has also been found in diverse applications including batteries16, cosmetics17, and catalysts18. Until now, MgO-based magnetic field sensors19, humidity sensors20 and gas sensors21 have been proposed and intensively investigated. However, MgO-based chemical liquid solution sensors have not been clearly reported yet.
In this study, we successfully fabricated MgO-based EIS biosensors with a pretty high pH sensitivity of 61 mV/pH. Furthermore, CF4 plasmas was used to shape nanostructures22 and stabilize the material properties of the MgO membrane. Results indicate that formation of nanostructures can enlarge the contact area and hence optimize the sensing performance. To characterize the influence of CF4 plasma on the MgO membrane, field-emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), atomic force microscopy (AFM), and secondary ion mass spectroscopy (SIMS) were conducted. Moreover, pH sensitivity, linearity, hysteresis, and drift rates were measured to study the sensing behaviors. These comprehensive studies of the MgO-based EIS biosensors investigate the biochemical sensing properties of MgO-based biosensors and the surface material reaction of the MgO membrane. Furthermore, possible integration of MgO-based or MgO composite material-based devices may be developed, stemming from the solution/MgO interface research.
Results and Discussion
Physical Properties
The schematic structure of a MgO-based EIS-biosensor is shown in Fig. 1. To characterize the surface of the MgO membrane treated with CF4 plasma, multiple material analysis techniques including FESEM, XRD, AFM and SIMS were used. MgO, an alkaline earth oxide, is abundant on earth and incorporating MgO as the membrane may lower the cost of fabrication of biosensors in future industrial applications. A study of surface morphology of the MgO film was realized by FESEM images as shown in Fig. 2(a),(b) and (c). The image of the as-deposited MgO film as shown in Fig. 2(a) presents that many large random flakes with the size around 0.1 µm were distributed on top of the membrane. As the MgO film was treated with annealing, fewer irregular-shaped flakes were distributed on top of the film as shown in Fig. 2(b). Moreover, as the MgO film was treated with CF4 plasma, all the flakes were gone. Instead, only nano-sized grains existed on top of the membrane as shown in Fig. 2(c). Compared with annealing, CF4 plasma treatment could effectively form nanograins, which might enhance the sensing performance.
Since the plasma treatment might be a useful method to boost the sensing properties of the MgO film, XRD, AFM and SIMS were used to evaluate the influence of plasma treatment time on the MgO film. To examine the crystalline structure of the MgO membrane, XRD was used to monitor the MgO crystals with various CF4 plasma treatment time. As shown in Fig. 3, as the plasma treatment time increased from 15 sec to 60 sec, the strongest crystallized film occurred at the plasma treatment time of 60 sec. Furthermore, to zoom in the nano-sized grain on top of the surface, AFM analysis was conducted to view the nanograins on top of the membrane as shown in Fig. 4. AFM images reveal the surface scan of the MgO film with no plasma treatment, with plasma treatment time of 15 sec with plasma treatment time of 30 sec, and with plasma treatment time of 60 sec as shown in Fig. 4. AFM analyses indicate the largest size of the MgO nanograins were generated with CF4 plasma treatment time of 60 sec. Consistent with the XRD patterns, the largest grains with the strongest crystallization occurred at the plasma treatment time of 60 sec.
To gain insight to the influence of fluorine atoms on the MgO film, SIMS was used to detect the fluorine atom distribution inside the MgO/Si film, as shown in Fig. 5. Compared with the as-deposited MgO film, fluorine atom accumulation can be observed near the surface of the MgO film and around the interface of MgO/Si. Since F atoms could bond with dangling bonds and fill the vacancies near the surface and interface, stronger crystallization could be observed for the CF4 plasma-treated samples in line with the XRD and AFM analyses. Fixing defects by CF4 plasma might enhance the material quality and sensing capability.
Sensing characterization
After material analyses, the pH sensitive performance of MgO sensing membrane was examined. Sensing performance including pH sensitivity, linearity, hysteresis effects, and drifting voltages before and after plasma treatments could be observed. The sensing parameters were taken by using HP4284A precision LCR meter. To make the surface reaction stable, all the samples were soaked in the RO water for 12 hours. The corresponding voltages in the C-V curves for all the samples were calculated with 0.4 Cmax as the reference. Then, the threshold voltage changes versus the pH values could be extracted.
Moreover, equation (1)23 portrays the flat band voltage of the EIS structure as follows:
where ERef is the reference electrode potential, χsol is the surface dipole potential of the solution, Φsi is the work function of silicon, and ψ0 is the liquid junction potential difference. All these terms are fixed values except for ψ0, and it is this term which causes the EIS structure responsive to the tested solution owing to polarization and the formation of the potential barrier, which connects to the quantity or concentration of H+ ions.
In addition, the site-binding model describes the ionic consumption procedures between the solution/membrane interface24,25,26. The measured voltage on the surface potential (ψ) can be expressed as a function of the membrane and the pH concentration of the electrolyte. The value of (ψ) can be figured out using Eq. (2).
where k is Boltzmann’s constant, T is the temperature, q is the elementary charge, pHpzc is the pH value with no charge, and β is a factor that indicates the sensitivity of the gate membrane. Furthermore, the β is closely connected to the density of surface hydroxyl groups, as described in Eq. (3).
where Ns is the number of surface site per unit area and CDL is the double layer capacitance based on the Gouy–Chapman–Stern model27.
Apparently, from Equation (3), it is clear that the higher the surface site density Ns is, the higher the pH sensitivity and linearity the membrane will have. The surface site density is closely related to the surface roughness and the material quality of the membrane. Varying the pH value of the electrolyte could result in the flat band voltage shift of the C-V curves. Based on the material analyses and the site binding model, CF4 plasma treatment could increase the roughness and enhance crystallization. Therefore, the surface site density for the sample with plasma treatment could be larger than the as-deposited sample and hence have higher sensing performance.
To evaluate the pH sensitivity of the MgO-based EIS device, a set of C-V curves at pH values of 2, 4, 6, 8, 10, and 12 were measured. In addition, the sensitivity and linearity could be calculated from these C-V curves. (We set 0.4 Cmax as the reference and extract the voltage variation versus the change of the pH value). The normalized C-V curves without CF4 plasma treatment is shown in Fig. 6(a) and the normalized C-V curves with plasma treatment for 60 sec are shown in Fig. 6(b). Furthermore, the sensitivity and linearity without plasma treatment and with plasma treatment for 15 sec, 30 sec, and 60 sec calculated from the C-V curves are plotted in Fig. 6(c). Consistent with the material analyses, the MgO membrane with plasma treatment for 60 sec exhibited lager sensitivity of 61.37 mV/pH and linearity of 99.9% than all the other samples, indicating that the membrane with stronger crystallization and larger roughness enhance the pH sensitivity and linearity of the membrane. Moreover, incorporation of fluorine atoms might improve the surface and interfacial material quality and increase the surface site density. Based on recent studies28, 29, CF4 plasma treatment could generate surface sites. In addition, the increase of the surface sites could transform the surface morphologies as revealed in AFM images as shown in Fig. 430. CF4 plasma could cause the membrane fluorinated and hence induce the formation of the fluorine atom related surface sites, which could enhance detection of various ions on the surface31, 32. Therefore, the number of the surface sites could be increased and the sensitivity of the membrane with CF4 plasma treatment could be enhanced. Therefore, CF4 plasma treatment might increase the density of binding sites and enlarge the value of β.
Furthermore, the hysteresis effects of MgO sensing membranes prepared under various plasma treatment conditions is shown in Fig. 7(a). The EIS biosensors were submerged in the solutions of the pH loop of 7 → 4 → 7 → 10 → 7. After 11 cycles (7 → 4 → 7 → 10 → 7) of operations as shown in Fig. 7(b), the hysteresis voltage of the sample without treatment (as-deposited) and with CF4 plasma for 60 sec increased to 55.51 mV and 5.57 mV, respectively. The plasma treatment could effectively remove the dangling bonds and fix the defects to sustain excellent performance and stability. Since hysteresis effects might be attributed to the dangling bonds of the defect structure of the membrane, these sites could interact with the hydroxyl groups and cause the hysteresis effects. Results indicate that the sample with plasma treatment for 60 sec had the least hysteresis voltage of 4.98 mV, indicating that plasma treatment could effectively remove the dangling bonds and fix the defects. Moreover, the drift voltage of the membrane could be detected by putting the biosensor into the solution of the pH value of 7 for a period of time and measuring the shift of the gate voltage. The drift voltages of the pH-sensitive sensor were measured as shown in Fig. 7(c). Similarly, the sample with CF4 plasma treatment for 60 sec had the least drift voltage of 1.03 mV/hr. Since the voltage drift effect could be explained by the hopping and/or trap-limited transport of water-related species, localized defects or dangling bonds might react with the solution of pH value of 7 and cause the drift voltage7. Plasma treatment could effectively mitigate the defects and passivate the dangling bonds. Therefore the voltage drift effect could be minimized.
Finally, to reveal the selectivity of the EIS biosensor, the sensitivity of potassium ions and sodium ions were included in the revised manuscript so that the selectivity among H+, Na+, and K+ could be presented for the EIS biosensor with MgO membrane. At first, we prepared the 5 mM Tris/HCl buffer solution and the pH value of the solution was kept at 8.7. After that, we used the micropipette to control the concentrations of sodium and potassium ions in the range between 10−5 to 10−1 M with injection of 1 M NaCl/Tris-HCl and 1 M KCl/Tris-HCl into buffer electrolyte, respectively. Then, we picked the as-deposited sample and the sample treated with 60 sec CF4 plasma for comparison. The pNa and pK sensitivity of the as-deposited sample are 10.12 mV/pNa and 8.36 mV/pK, respectively. Moreover, the pNa and pK sensitivity of the sample with 60 sec CF4 plasma were 33.60 mV/pNa and 30.15 mV/pK, respectively. Furthermore, the sensitivities for H+, Na+, and K+ of the MgO sensing membrane treated with 60 sec CF4 plasma was graphed and compared as shown in Fig. 8. It can be seen that the EIS structure with MgO sensing membrane was more responsive to H+ ion (61.37 mV/pH) compared with Na+ (33.60 mV/pNa) and K+ (30.15 mV/pK).
Conclusions
MgO-based EIS structures grown on Si substrate by RF sputtering were fabricated. Material analyses indicate that incorporating CF4 plasma treatment for 60 sec on the MgO membrane could enhance crystallization and increase the size of the nanograin. Furthermore, incorporation of F atoms could fix the defects and improve the material quality of the MgO membrane. Therefore, the pH sensing performance of the MgO membrane could be effectively optimized. Results show that MgO membrane with plasma treatment for 60 sec exhibited larger sensitivity of 61.37 mV/pH and linearity of 99.9%. Moreover, the EIS structure with MgO sensing membrane was more responsive to H+ ion compared with Na+ and K+ ions. MgO-based EIS membranes with CF4 plasma treatment show promise for future industrial biosensing applications.
Methods
The electrolyte-insulator-semiconductor (EIS) structures incorporating MgO sensing membranes were manufactured 4 inch n-type(100) silicon wafers with a resistivity of 5–10 Ω-cm. The wafers were cleaned with a normal RCA process and utilized HF-dip (HF:H2O = 1:100) to take away the native oxide before the deposition of MgO films. After the treatment, a 60 nm MgO film was deposited on the Si substrate by radio frequency (RF) sputtered from a magnesium target in diluted O2 surroundings (Ar/O2 = 25sccm/10sccm), The RF power and the ambient pressure were 150 Watt and 20 mTorr, respectively. After deposition, some wafers were subjected to a post-CF4 plasma treatment in a plasma-enhanced chemical vapor deposition (PECVD) system with an RF power of 30 W and a processing pressure of 300 mTorr for 15 sec, 30 sec and 60 sec, respectively. The instrumental type of PECVD was SAMCO PD-220N for the deposition of silicon-based thin films and plasma treatment. Then, the wafers were consequently processed with rapid thermal annealing (RTA) using a standard thermal annealing system under ambient N2 condition for 30 sec at 600 °C temperatures. Afterwards, Al film with 300nm-thick was deposited on the back-side contact of the Si chip. The sensing film size was defined through photolithographic processing under a photosensitive epoxy (SU8–2005, Micro-Chem). EIS structures were then attached on the copper lines of a printed circuit board (PCB) by using a silver gel to structure conductive lines. Epoxy package was used to separate the EIS structure and the copper line. The detailed EIS structure was illustrated in Fig. 1.
Change history
17 April 2020
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
References
Bergveld, P. Development of an ion-sensitive solid-state device for neurophysiological measurements. IEEE Transactions on Biomedical Engineering. 1, 70 (1970).
Caras, S. & Janata, J. Field effect transistor sensitive to penicillin. Analytical Chemistry. 52, 1935 (1980).
Jimenez-Jorquera, C., Orozco, J. & Baldi, A. ISFET based microsensors for environmental monitoring. Sensors. 10, 61 (2009).
Stine, R. et al. Fabrication, optimization, and use of graphene field effect sensors. Analytical chemistry. 85, 509 (2012).
Kao, C.-H. et al. Multi-analyte biosensors on a CF4 plasma treated Nb2O5-based membrane with an extended gate field effect transistor structure. Sensors and Actuators B: Chemical. 194, 419 (2014).
Kao, C. H. et al. Effects of N2 and O2 annealing on the multianalyte biosensing characteristics of CeO2-based electrolyte–insulator–semiconductor structures. Sensors and Actuators B: Chemical. 194, 503 (2014).
Wu, M.-H., Cheng, C.-H., Lai, C.-S. & Pan, T.-M. Structural properties and sensing performance of high-k Sm2O3 membrane-based electrolyte–insulator–semiconductor for pH and urea detection. Sensors and Actuators B: Chemical. 138, 221 (2009).
Oren, Y. & Litan, A. State of the solution-membrane interface during ion transport across an ion-exchange membrane. The Journal of Physical Chemistry. 78, 1805 (1974).
Grieshaber, D., MacKenzie, R., Voeroes, J. & Reimhult, E. Electrochemical biosensors-sensor principles and architectures. Sensors. 8, 1400 (2008).
Pearton, S. et al. Wide band gap ferromagnetic semiconductors and oxides. Journal of Applied Physics. 93, 1 (2003).
Chandran, A. et al. Preparation and characterization of MgO nanoparticles/ferroelectric liquid crystal composites for faster display devices with improved contrast. Journal of Materials Chemistry C. 2, 1844 (2014).
Du, Z., Zhang, X., Yue, Y. & Wu, H. Effect of MgO on structure and dielectric properties of CaO–Al2O3–B2O3–SiO2 glasses. Surface Review and Letters. 19, 1250063 (2012).
Torres, F. J. & Alarcón, J. Effect of MgO/CaO ratio on the microstructure of cordierite-based glass-ceramic glazes for floor tiles. Ceramics international. 31, 683 (2005).
Furukawa, Y. et al. Photorefraction in LiNbO3 as a function of [Li]/[Nb] and MgO concentrations. Applied Physics Letters. 77, 2494 (2000).
Habibah, Z. et al. Sol-Gel Derived Nano-Magnesium Oxide: Influence of drying temperature to the dielectric layer properties. IOP Conference Series: Materials Science and Engineering, IOP Publishing. 012006 (2013).
Chen, J., Zhao, H., He, J. & Wang, J. Si/MgO composite anodes for Li-ion batteries. Rare Metals. 30, 166 (2011).
Chimenos, J. et al. Removal of ammonium and phosphates from wastewater resulting from the process of cochineal extraction using MgO-containing by-product. Water Research. 37, 1601 (2003).
Chen, P., Zhang, H.-B., Lin, G.-D., Hong, Q. & Tsai, K. Growth of carbon nanotubes by catalytic decomposition of CH4 or CO on a Ni/MgO catalyst. Carbon. 35, 1495 (1997).
Chen, J., Feng, J. & Coey, J. Tunable linear magnetoresistance in MgO magnetic tunnel junction sensors using two pinned CoFeB electrodes. Applied Physics Letters. 100, 142407 (2012).
Shukla, S. et al. Nano-like magnesium oxide films and its significance in optical fiber humidity sensor. Sensors and Actuators B: Chemical. 98, 5 (2004).
Tao, Y., Cao, X., Peng, Y. & Liu, Y. A novel cataluminescence gas sensor based on MgO thin film. Sensors and Actuators B: Chemical. 148, 292 (2010).
Kao, C. H. et al. Fabrication of multianalyte CeO2 nanograin electrolyte–insulator–semiconductor biosensors by using CF4 plasma treatment. Sensing and Bio-Sensing Research. 5, 71 (2015).
Jamasb, S., Collins, S. D. & Smith, R. L. A physical model for threshold voltage instability in Si3N4-gate H+ -sensitive FET’s (pH ISFET’s). IEEE Transactions on Electron Devices. 45, 1239 (1998).
Bousse, L., De Rooij, N. & Bergveld, P. Operation of chemically sensitive field-effect sensors as a function of the insulator-electrolyte interface. IEEE Transactions on Electron Devices. 30, 1263 (1983).
Fung, C. D., Cheung, P. W. & Ko, W. H. A generalized theory of an electrolyte-insulator-semiconductor field-effect transistor. IEEE Transactions on Electron Devices. 33, 8 (1986).
Van Hal, R., Eijkel, J. & Bergveld, P. A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parameters. Sensors and Actuators B: Chemical. 24, 201 (1995).
Oldham, K. B. A Gouy–Chapman–Stern model of the double layer at a (metal)/(ionic liquid) interface. Journal of Electroanalytical Chemistry. 613, 131 (2008).
Jucius, D., Grigaliūnas, V., Kopustinskas, V., Lazauskas, A. & Guobienė, A. Wettability and optical properties of O 2 and CF 4 plasma treated biaxially oriented semicrystalline poly (ethylene terephthalate) films. Applied Surface Science 263, 722 (2012).
Woodward, I., Schofield, W., Roucoules, V. & Badyal, J. Super-hydrophobic surfaces produced by plasma fluorination of polybutadiene films. Langmuir 19, 3432 (2003).
Pan, T.-M., Huang, M.-D., Lin, W.-Y. & Wu, M.-H. A urea biosensor based on pH-sensitive Sm 2 TiO 5 electrolyte–insulator–semi-conductor. Analytica chimica acta 669, 68 (2010).
Huang, C.-H. et al. High Polarization and Low-Repulsion HfO Thin Film for Alkali Metal Ion Detections by Plasma System With a Complementary Filter. IEEE Sensors Journal 13, 2459 (2013).
Lu, T.-F. et al. Characterization of K+ and Na+-sensitive membrane fabricated by CF4 plasma treatment on hafnium oxide thin films on ISFET. Journal of The Electrochemical Society 158, J91 (2011).
Acknowledgements
This work has been supported in part by the Ministry of Science and Technology of Taiwan, ROC under Contract No: MOST 104-2221-E-260-002 -MY3 and MOST 104-2221-E-182-042. Moreover, this work was supported by the Chang Gung University under the contract of CMRPD2F0091.
Author information
Authors and Affiliations
Contributions
Chyuan-Haur Kao, Chia Lung Chang, Chan-Yu Lin, and Hsiang Chen designed the research. Chia Lung Chang and Hsiang Chen devised the crystal growth method, grew and characterized the materials. Wei Ming Su, Yu Tzu Chen, Chien Cheng Lu, Yu Shan Lee, Chen Hao Hong analyzed the data and wrote the paper. Chia Lung Chang graphed the device structure of Fig. 1.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kao, CH., Chang, C.L., Su, W.M. et al. Magnesium Oxide (MgO) pH-sensitive Sensing Membrane in Electrolyte-Insulator-Semiconductor Structures with CF4 Plasma Treatment. Sci Rep 7, 7185 (2017). https://doi.org/10.1038/s41598-017-07699-3
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-07699-3
This article is cited by
-
A dual-functional flexible sensor based on defects-free Co-doped ZnO nanorods decorated with CoO clusters towards pH and glucose monitoring of fruit juices and human fluids
Nano Convergence (2022)
-
Transition-Metal Element (Ni, Co)-Doped MgO Microflowers for Electrochemical Biosensor Applications
JOM (2019)
-
A smart LPG sensor based on chemo-bio synthesized MgO nanostructure
Journal of Materials Science: Materials in Electronics (2018)
Comments