Abstract
Ion beam sputtering and ion beam sputtering/mixing deposition techniques were used to produce thin bioactive glass coatings on titanium substrate. It was found that as-deposited coatings were amorphous. Scanning electron microscopical examination showed that the coatings had a uniform and dense structure and that fabrication parameters affected the surface morphology of the coatings. The surface Ca/P ratio of the coatings, which varied from 5.9 to 8.6 according to semi-quantitative EDX analyses, was correlated with the fabrication condition. Depth profiling of the coatings revealed four distinct zones: the top surface, the thin coating zone, the intermixed zone of coating and substrate, and the substrate. Scratch tests showed that the coatings adhered well to the substrate.
Similar content being viewed by others
References
L. L. Hench and H. A. Paschall, J. Biomed. Mater. Res. Symp. 4 (1973) 25-42.
L. L. Hench, J. Am. Ceram. Soc. 74 (1991) 1487-1510.
L. L. Hench and J. Wilson, (eds), “An Introduction to Bioceramics” (World Scientific, Singapore, 1993).
R. G. T. Geesink, K. De Groot, C. P. A. T. Klein and P. Serekian, J. Bone Joint Surg. 70B (1988) 17-22.
J. Breme, Y. Zhou and L. Groh, Biomaterials 16 (1995) 239-244.
H. Dasarathy, C. Riley and H. D. Coble, J. Biomed. Mater. Res. 27 (1993) 477-482.
W. R. Lacefield, in “Bioceramics: Material Characteristics Versus In Vivo Behavior”, edited by P. Ducheyne and J. E. Lemons (Annals of the New York Academy of Science, New York, 1988) pp. 72-80.
H. Monma, J. Ceramic Soc. Japan, Int. Edition 101 (1993) 718-720.
J. G. C. Wolke, V. J. P. C. Der Waerden, K. De Groot and J. A. Jansen, Biomaterials 18 (1997) 483-488.
R. K. Singh, F. Qian, V. Nagabushnam, R. Damodaran and B. M. Moudgil, ibid. 15 (1994) 522-528.
C. K. Wang, J. H. Lin, C. P. Ju, H. C. Ong and R. P. Chang, ibid. 18 (1997) 1331-1338.
H. B. Wen, J. R. De Wijin, F. Z. Cui and K. De Groot, ibid. 19 (1998) 215-221.
M. Wang, X. Y. Yang, K. A. Khor and Y. Wang, J. Mater. Sci: Mater. Med. 10 (1999) 269-273.
Q. Y. Zhang, Z. H. Long, C. S. Ren, B. H. Guo, D. Q. Xu and T. C. Ma, Surf. Coat. Technol. 103–104 (1998) 195-199.
J. L. Ong, L. C. Lucas, W. R. Lacefield and E. D. Rigney, Biomaterials 13 (1992) 249-254.
J. L. Ong and L. C. Lucas, ibid. 15 (1994) 337-341.
C. X. Wang, Z. Q. Chen, M. Wang, Z. Y. Liu and P. L. Wang, J. Biomed. Mater. Res. 55 (2001) 587-595.
T. Kitsugi, T. Nakamura, M. Oka, Y. Senaha, T. Goto and T. Shibuya, ibid. 30 (1996) 261-269.
J. A. Helsen, J. Proost, J. Schrooten, G. Timmermans, E. Brauns and J. Vanderstraeten, J. Eur. Ceram. Soc. 17 (1997) 147-152.
M. C. Cotell, Appl. Surf. Sci. 69 (1993) 140-148.
C. X. Wang, Z. Q. Chen and H. L. Zhang, “Proceedings of the 20th Annual International Conference of IEEE”, Hong Kong (1998) 2890-2892.
C. X. Wang, Z. Q. Chen and M. Wang, “Proceedings of the 10th International Conference on Biomedical Engineering”, Singapore (2000) 263-264.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wang, C.X., Chen, Z.Q. & Wang, M. Fabrication and characterization of bioactive glass coatings produced by the ion beam sputter deposition technique. Journal of Materials Science: Materials in Medicine 13, 247–251 (2002). https://doi.org/10.1023/A:1014050715535
Issue Date: