Abstract
Novel, thick-film biosensors have been developed for the determination of l-glutamate in foodstuffs. The sensors were prepared by immobilization of l-glutamate oxidase by using polycarbamylsulfonate-hydrogel on a thick-film sensor. l-Glutamate oxidases obtained from Streptomyces sp. with different degree of purification were compared with their characteristic response to l-glutamate at different conditions and for their specificity, inhibition, and storage properties. These sensors were applied to determine monosodium glutamate in soy sauce samples and show good correlation with colorimetric method.
Similar content being viewed by others
References
Böhmer A, Müller A, Passarge M, Liebs P, Honeck H, Müller HG (1989) A novel L-glutamate oxidase from Streptomyces endus. Purification and properties. Eur. J. Biochem. 182: 327–332.
Coppola ED, Christie SN, Hanna JG (1975) Fast, short-column separation and fluorometric determination of monosodium glutamate in foods. J.A.O.A.C. 58: 58–61.
Davis JL, Cherkin A, Hewitt MD (1981) Intraventricular Nacetyl-L-glutamate induces retrograde amnesia in chicks. Pharm. Biochem. Behav. 14: 919–920.
Gündüz T, Gündüz N, Kiliç E, Köseğglu F, Öztas SG (1988) Titrations in non-aqueous media. Part X. Potentiometric and conductimetric titrations of amino acids with tetrabutylammonium hydroxide in pyridine and acetonitrile solvents. Analyst 113: 715–719.
Kotte H, Gründig B, Vorlop KD, Strehiltz B, Stottmeister U (1995) Methylphenazonium-modified enzyme sensor based on polymer thick films for subnanomolar detection of phenols. Anal. Chem. 67: 65–70.
Kusakabe H, Midorikawa Y, Fujishima T (1984) Methods for determining L-glutamate in soy sauce with L-glutamate oxidase. Agric. Biol. Chem. 48: 181–184.
Li QS, Zhong JJ (1996) Enhancement of L-glutamate oxidase production in liquid fermentation of Streptomyces sp. by calcium addition. Biotech. Tech. 10: 453–456 ]
Mizutani F, Sato Y, Hirata Y, Yabuki S (1998) High-throughput flow-injection analysis of glucose and glutamate in food and biological samples by using enzyme/polyion complex-bilayer membrane-based electrodes as the detectors. Biosensors Bioelectron. 13: 809–815.
Orwar O, Jardemark K, Jacobson I, Moscho A, Fishman H, Scheller R, Zare R (1996) Patch-clamp detection of neurotransmitters in capillary electrophoresis. Science 272: 1779–1782.
Passarge M, Böhmer A, Renneberg R, Müller HG (1985). Verfahren zur Herstellung einer mikrobiellen L-Glutaminsäure-Oxidase. GDR Patent 240910.
Passarge M, Böhmer A, Stengel C, Renneberg R, Liebs P, Fleck W, Müller HG (1986). Verfahren zur Herstellung einer mikrobiellen (H2O2 bildenden) L-Glutaminsäure-Oxidase GDR Patent 261932.
Renneberg R, Kaiser G, Scheller F, Tsujisaka, Y (1985) Enzyme sensor for pullulan and pullulanase activity. Biotechnol. Lett. 7: 809–812.
Sdraulig R, Rogers LJ, Boura AL (1980) Glutamate and specific perceptual input interact to cause retarded learning in chicks. Physiol. Behav. 24: 493–500.
Turski L, Havemann U, Kuschinsky K (1982) On the possible role of excitatory amino acids in the striatum in mediating morphineinduced muscular rigidity. Pharm. Biochem. Behav. 17: 715–719.
Wollenberger U, Scheller FW, Böhmer A, Passarge M, Müller HG (1989) A specific enzyme electrode for L-glutamate – Development and application. Biosensors 4: 381–391.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kwong, A.W., Gründig, B., Hu, J. et al. Comparative study of hydrogel-immobilized l-glutamate oxidases for a novel thick-film biosensor and its application in food samples. Biotechnology Letters 22, 267–272 (2000). https://doi.org/10.1023/A:1005694704872
Issue Date:
DOI: https://doi.org/10.1023/A:1005694704872