Review
Microfluidic tools for quantitative studies of eukaryotic chemotaxis

https://doi.org/10.1016/j.ejcb.2011.05.006Get rights and content

Abstract

Over the past decade, microfluidic techniques have been established as a versatile platform to perform live cell experiments under well-controlled conditions. To investigate the directional responses of cells, stable concentration profiles of chemotactic factors can be generated in microfluidic gradient mixers that provide a high degree of spatial control. However, the times for built-up and switching of gradient profiles are in general too slow to resolve the intracellular protein translocation events of directional sensing of eukaryotes. Here, we review an example of a conventional microfluidic gradient mixer as well as the novel flow photolysis technique that achieves an increased temporal resolution by combining the photo-activation of caged compounds with the advantages of microfluidic chambers.

Introduction

Cell motility and chemotaxis are ubiquitous throughout the living world. They play an essential role for many biomedical processes ranging from embryonic development to immune response and tumor spreading (Horwitz and Parsons, 1999). Substantial progress has been made in the study of bacterial chemotaxis, where detailed knowledge of the underlying pathways and quantitative models are available (Berg, 2003). Signaling in eukaryotic cells, on the other hand, is more complex and, to date, much less well understood. Our knowledge of the chemotactic pathways that link the membrane receptor to the dynamics of the cytoskeletal machinery in eukaryotic cells is based on a number of selected model organisms like neutrophils or Dictyostelium discoideum (Van Haastert and Devreotes, 2004). In recent years our knowledge has advanced to the point, where quantitative tests need to be performed (Bagorda and Parent, 2008). Microfluidic flow can provide an exceptionally well controlled environment for such investigations.

To date, mathematical modeling focuses predominantly on phenomenological, low-dimensional descriptions as many molecular details of the chemotactic pathways still remain unknown. For example, a variety of models have been proposed to explain the initial stages of chemotactic signaling, generally referred to as directional sensing. They are based on different paradigms like the combination of a local activator with a rapidly diffusing inhibitory component (local excitation/global inhibition – LEGI – models) (Levchenko and Iglesias, 2002, Levine et al., 2006, Parent and Devreotes, 1999), on Turing-type instabilities (Meinhardt, 1999), or on bistable dynamics (Beta et al., 2008a, Mori et al., 2008). While all of these models show an initial symmetry breaking in a chemotactic cell, they predict different dose–response characteristics and dynamics for the internal asymmetry as a function of the external gradient signal. Thus, quantitative experimental tools are needed to test the modeling predictions in single cell studies with well-controlled external spatio-temporal gradient stimuli.

The classical setup to expose cells to a spatially non-uniform concentration field is the micropipette assay, a convenient qualitative test for directional responses. However, the chemoattractant gradient is poorly defined and changes in the course of time as more substance is diffusing out of the micropipette. Early efforts to generate spatially linear and temporally stable chemical gradients led to the development of diffusion based gradient chambers. A gradient is established by diffusion inside a porous medium or a small gap between two large reservoirs containing solutions of different concentrations. The most widely known versions of diffusion chambers are the Boyden (1962), Zigmond (1977), and Dunn chambers (Zicha et al., 1991). For a review of gradient techniques see Keenan and Folch (2008).

With the advent of microfluidic techniques, an entire new range of devices became available to perform highly controlled live cell stimulation experiments with high spatial and temporal resolution (Breslauer et al., 2006). In particular, with the invention of soft lithography (Xia and Whitesides, 1998), such devices became readily accessible to a wide community of users. Soft lithography is based on a two-step procedure: First, a master wafer is designed and generated based on standard photolithography. Second, molding of polydimethylsiloxane (PDMS) against the master wafer yields a microstructured polymer block that is sealed with a glass cover slip. Detailed, well-tested, and standardized protocols are available for this fabrication procedure (Whitesides et al., 2001). There are a number of outstanding advantages that make these devices an excellent tool for cell biological applications. They can be fabricated with a spatial resolution on the micron scale, so that the physicochemical environment of an individual cell can be controlled with great precision. Only a moderate level of equipment is necessary to fabricate such devices. The fabrication itself is straightforward, inexpensive, and reproducible. The devices are biocompatible and, due to the integrated cover slip, well-suited for optical microscopy.

Microfluidic chambers can be fabricated in a great variety of geometries and dimensions. They can be tailored according to the requirements of a specific experiment. On the one hand, many chemotaxis studies require long time migration experiments to gather sufficient statistics of the various motion parameters, but also to allow the study of temporal variability of the chemotactic parameters of individual cells. The latter is even more important as gene expression levels and consequently the chemotactic response may vary from cell to cell. Here, larger chambers are needed that exhibit sufficient long-term stability of a chemoattractant gradient. Such devices typically come with a relatively low time resolution (i.e. gradients change in minutes) but allow for the simultaneous observation of large cell populations (i.e. hundreds of cells). On the other hand, in order to investigate intracellular signaling in chemotactic cells, the experimental setup has to meet very different requirements. The first directional signaling events occur within only a few seconds after the cell is exposed to the external gradient stimulus. Such events are typically observed on the level of individual cells with the help of fluorescence techniques. Thus, single cell stimulation experiments with a high time resolution are necessary to investigate such processes.

In the following, we will exemplarily review two devices that meet these opposing demands, a classical microfluidic gradient mixer for long-term migration studies and the flow photolysis technique for rapid stimulation of individual cells.

Section snippets

The microfluidic gradient mixer

In 2000, the first microfluidic gradient mixer was introduced by Jeon et al. (2000). It is based on a pyramidal network of microfluidic channels that acts as a mixing cascade to generate a linear gradient between two arbitrarily chosen concentration levels. Solutions of the minimal and maximal concentration are introduced into the inlets and continuously pumped through the device. At each bifurcation in the pyramidal network, the flow is divided into an upper and a lower branch and diffusively

The flow photolysis technique

In the microfluidic gradient mixer that was introduced in the previous section, concentration profiles can be defined with micrometer resolution. This is sufficient for most chemotaxis assays. The temporal resolution in this device is determined by the pumping rate and the extension of the microfluidic network. To establish a gradient signal in this device, solutions with the respective concentrations have to be pumped through the entire mixing cascade that is shown in Fig. 1, until a stable

Other microfluidic approaches

The two examples of microfluidic gradient devices discussed above belong to the class of flow-based gradient generators (Kim et al., 2010). They are characterized by the presence of a continuous fluid flow over the region where the gradient is generated and where the cells reside. The design principles of these devices rely on the well-predictable, laminar properties of low Reynolds number flows that prevail at the micrometer scale. These properties allow for precise control and fine tuning of

Conclusion

Over the past decade, microfluidic technology has made significant contributions to advance our understanding of eukaryotic chemotaxis. In particular, microfluidics opened up new opportunities to perform systematic and quantitative live cell experiments. In most cases, microfluidic devices are designed to deliver one particular type of cue in a highly controlled fashion to cells in a microfluidic channel. This is, however, very different from the natural environment of a cell. In vivo, cells

Acknowledgement

We thank our coworkers and collaborators that have been involved in this work, in particular, Loling Song, Albert Bae, Danica Wyatt, Toni Fröhlich, Hendrik U. Bödeker, Sharvari M. Nadkarni, Carl Franck, Wouter-Jan Rappel, and William F. Loomis.

References (47)

  • H.C. Berg

    E. coli in Motion

    (2003)
  • E. Berthier et al.

    An arrayed high-content chemotaxis assay for patient diagnosis

    Integr. Biol.

    (2010)
  • C. Beta et al.

    A bistable mechanism for directional sensing

    New J. Phys.

    (2008)
  • C. Beta et al.

    Chemotaxis in microfluidic devices – a study of flow effects

    Lab Chip

    (2008)
  • C. Beta et al.

    Flow photolysis for spatiotemporal stimulation of single cells

    Anal. Chem.

    (2007)
  • N. Bhattacharjee et al.

    A neuron–benign microfluidic gradient generator for studying the response of mammalian neurons towards axon guidance factors

    Integr. Biol.

    (2010)
  • S. Boyden

    Chemotactic effect of mixtures of antibody and antigen on polymorphonuclear leucocytes

    J. Exp. Med.

    (1962)
  • D.N. Breslauer et al.

    Microfluidics-based systems biology

    Mol. BioSyst.

    (2006)
  • J.A. Burdick et al.

    Fabrication of gradient hydrogels using a microfluidics/photopolymerization process

    Langmuir

    (2004)
  • K. Campbell et al.

    Generation of complex concentration profiles in microchannels in a logarithmically small number of steps

    Lab Chip

    (2007)
  • S.Y. Cheng et al.

    A hydrogel-based microfluidic device for the studies of directed cell migration

    Lab Chip

    (2007)
  • E. Cukierman et al.

    Cell interactions with three-dimensional matrices

    Curr. Opin. Cell Biol.

    (2002)
  • S.K.W. Dertinger et al.

    Generation of gradients having complex shapes using microfluidic networks

    Anal. Chem.

    (2001)
  • Cited by (23)

    • On the competition between mixing rate and uniformity in a coaxial hydrodynamic focusing mixer

      2020, Analytica Chimica Acta
      Citation Excerpt :

      Rapid microfluidic mixers have been critical in studies of protein folding [1–7], enzyme reactions [8–10], and cell activation [11,12], as well as leveraged in disease detection [13–15], drug development [16–18], and sequencing or synthesis of nucleic acids [19–21].

    • Light-Activated Chemotaxis

      2016, Cell Chemical Biology
      Citation Excerpt :

      Methods using hydrogels can simulate the extracellular matrix (Luhmann and Hall, 2009), but controlling the chemical gradient in these systems is challenging. A combination of microfluidics and photoactivatable chemotactic agents enables tighter temporal control of concentration gradients, which opens a path to study the directional sensing of eukaryotes (Beta and Bodenschatz, 2011). In a new report, Carsten Schultz and coworkers describe steps toward realizing the potential of PPG-conjugated biological effectors to rapidly build chemical gradients in intact tissues and organisms in a light-controlled manner (Hövelmann et al., 2016).

    • Cultivation of yeast in diffusion-based microfluidic device

      2016, Biochemical Engineering Journal
      Citation Excerpt :

      Convection-based gradient generators use laminar flow mass transport in the microchannels. These generators have previously been used to evaluate microbial growth and viability [18], identify factors affecting enzyme reaction rate [19], and study chemotaxis with different microchannel geometries [20–23]. However, in convective systems a major challenge is the necessity of constructing a microchannel network, in order to uniformly distribute the flow and to obtain proper gradient generation [17].

    View all citing articles on Scopus