Regular paper electrophoresisDetermination of barium and strontium by capillary zone electrophoresis using an electrolyte containing sulfonazo III
References (26)
- et al.
J. Chromatogr. A
(1994) - et al.
J. Chromatogr.
(1989) - et al.
J. Chromatogr. A
(1993) - et al.
J. Chromatogr. B
(1994) - et al.
J. Chromatogr. A
(1994) - et al.
Talanta
(1992) - et al.
J. Chromatogr. A
(1995) - et al.
J. Chromatogr. A
(1994) Chem. Br.
(1993)- et al.
Ion Chromatography. Principles and Applications
(1990)
Analyst
Analyst
Anal. Lett.
Cited by (29)
A novel pH-Dependent sensor for recognition of strontium ions in water: A hierarchically structured mesoporous architectonics
2023, TalantaCitation Excerpt :The high radioactivity and long half-life lead to these streams being classified as high-level waste. Both non-radioactive and radioactive Strontium are inevitable components of nuclear waste and spent nuclear fuel, being by-products of nuclear fission occurring in the reactors used in nuclear power plants [5,6]. are highly soluble in water and can readily be released into the environment.
Onsite-detection of barium and nickel from river, pond and tap water samples using gold nanoparticles as a chemical sensor
2017, Spectrochimica Acta - Part A: Molecular and Biomolecular SpectroscopyCitation Excerpt :Therefore, the monitoring of Ba(II) and Ni(II) in environmental samples is essential in order to take a preventive action to avoid the entering of these toxic substances into the human body. There are several instrumental techniques such as spectrophotometry [5,9–12], atomic absorption spectrometry (AAS) [13–16], inductively coupled plasma-atomic emission spectrometry (ICP-AES) [17,18], inductively coupled plasma-mass spectrometry (ICP-MS) [19,20], capillary electrophoresis (CE) [21] and neuron activation analysis (NAA) [22]. AAS, ICP-MS, ICP-AES, CE and NAA are very expensive instruments and require a time consuming tedious process for the sample preparation prior to instrumental analysis.
Analytical devices based on light-emitting diodes - A review of the state-of-the-art
2015, Analytica Chimica ActaCitation Excerpt :However, other analytical applications of liquid-core waveguides in capillaries have been described, some of them involving LEDs as light sources, and these have been reviewed by Dallas and Dasgupta [51]. Macka and co-workers have also remained active in the field of LED based absorption detectors for CE and over the years have demonstrated a range of applications [52–61]. This included, for example, a study of the use of a near-UV-LED (380 nm) with chromate, which is frequently used as displacement dye in the indirect detection of inorganic anions [62].
Removal of Co<sup>2+</sup>, Sr<sup>2+</sup> and Cs<sup>+</sup> from aqueous solution by phosphate-modified montmorillonite (PMM)
2011, DesalinationCitation Excerpt :The pH values of heavy metal solutions were also controlled at 5 ± 0.05 by using 0.05 M MES buffer. The MES buffer was used because no detectable complexation reactions occur between Co, Sr and Cs and MES buffer [20,21]. The solution pH was controlled to prevent the formation of metal hydroxides and carbonates.