Editorial
Transcatheter occlusion of patent ductus arteriosus: Which method to use and which ductus to close

https://doi.org/10.1016/S0002-8703(96)90334-8Get rights and content

Abstract

Many devices have been developed for transcatheter occlusion of PDA. Bulkiness of the device, complexity of the procedure, and significant residual complications make the majority of the devices unsuitable for routine clinical use. Although no randomized comparative clinical trials exist, on the basis of published literature and my personal experience, coil occlusion may be best suited to close small ducts (≤3.5 mm) and the adjustable buttoned device may be most appropriate for large PDAs (>3.5 mm). Clinical trials on larger patient populations than are currently available and long-term follow-up are necessary to further support these recommendations. Indications for transcatheter closure should be exactly as those used for surgical closure: PDA with audible continuous murmur with echo Doppler confirmation. The so-called silent ducts need not be closed.

References (65)

  • R Lochan et al.

    Transcatheter closure of patent ductus arteriosus with an adjustable buttoned device in an adult patient

    Am Heart J

    (1994)
  • PS Rao et al.

    Follow-up results of transvenous occlusion of patent ductus arteriosus with the adjustable buttoned device

    J Am Coll Cardiol

    (1995)
  • ND Bridges et al.

    Transcatheter closure of a large patent ductus arteriosus with the clamshell septal umbrella

    J Am Coll Cardiol

    (1991)
  • VE Verin et al.

    Results of transcatheter closure of patent ductus arteriosus with the Batallo-occluder

    J Am Coll Cardiol

    (1993)
  • PA Cambier et al.

    Percutaneous closure of small (<2.5 mm) patent ductus arteriosus using coil embolization

    Am J Cardiol

    (1992)
  • ZM Hijazi et al.

    Results of antegrade transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils

    Am J Cardiol

    (1994)
  • JW Moore et al.

    Percutaneous closure of the small patent ductus arteriosus using occluding spring coils

    J Am Coll Cardiol

    (1994)
  • RJ Sommer et al.

    Use of preformed Nitinol snare to improve transcather coil delivery in occlusion of patent ductus arteriosus

    Am J Cardiol

    (1994)
  • MA Ali Khan et al.

    Experience with 205 procedures of transcatheter closure of ductus arteriosus in 182 patients, with special reference to residual shunts and long-term follow-up

    J Thorac Cardiovasc Surg

    (1992)
  • TR Lloyd et al.

    Clinically silent patent ductus arteriosus

    Am Heart J

    (1994)
  • DT Balzer et al.

    Endarteritis associated with a clinically silent patent ductus arteriosus

    Am Heart J

    (1993)
  • C Gianturco et al.

    Mechanical device for arterial occlusion

    Am J Radiol

    (1975)
  • W Porstmann et al.

    Der Verschluss des Ductus arteriosus persistens ohne Thorakotomie (1, Miffeilung)

    Thoraxchirurgie

    (1967)
  • L Wierny et al.

    Transluminal closure of patent ductus arteriosus: long-term results of 208 cases treated without thoractomy

    Cardiovasc Intervent Radiol

    (1986)
  • M Takamiya

    Ductus closure without thoracotomy

    Jpn J Thorac Surg

    (1973)
  • K Sato et al.

    Transfemoral plug closure of patent ductus arteriosus: experience with 61 consecutive cases

    Circulation

    (1975)
  • S Furukawa et al.

    Catheter closure of patent ductus arteriosus without thoracotomy

    Kyobu Geka

    (1977)
  • Y Naito et al.

    Plug closure of patent ductus arteriosus without thoracotomy

  • Y Shimizu et al.

    Closure of PDA by a Porstmann method

    Kyobu Geka Gakkai Zasshi

    (1978)
  • WD Bussmann et al.

    Transfemoraler Verschlusse des Ductus arteriosus persistens

    Dtsch Med Wochenschr

    (1984)
  • J Leslie et al.

    Nonsurgical closure of patent ductus arteriosus: an experimental study

    Invest Radiol

    (1977)
  • WJ Rashkind et al.

    Transcatheter closure of a patent ductus arteriosus: successful use in a 3.5 kg infant

    Pediatr Cardiol

    (1979)
  • Cited by (29)

    • Management of adults with congenital heart disease with cardiovascular computed tomography

      2008, Journal of Cardiovascular Computed Tomography
      Citation Excerpt :

      Before consideration of transcatheter closure, a cardiac CT was performed to evaluate the coronary arteries as well as to accurately delineate the anatomy of the ductus (Fig. 6). In the presence of left ventricular volume overload identified by CT and a continuous murmur on her examination, she later underwent transcatheter placement of an 8-6mm Amplatzer Ductal Occluder (AGA Medical Corporation).16,17 Another patient with coarctation of the aorta underwent transcatheter therapy to address a segment of recoarctation, and a final patient with unrepaired cor triatriatum underwent surgical repair.

    View all citing articles on Scopus
    View full text