A gas sampling electromagnetic calorimeter using conductive plastic tubes

https://doi.org/10.1016/0168-9002(87)90288-9Get rights and content

Abstract

A prototype of gas sampling electromagnetic calorimeter with conductive plastic tubes was studied under practical conditions. An energy resolution of σEE = 20.4(E(GeV))12 (%) was obtained in the few-GeV region and the spatial resolu for 4 GeV electrons was σx = 5.4 mm for pads and σx = 2.2 mm for strips. No appreciable effect on the energy resolution was found by magnetic field of 1 kG applied perpendicularly to the anode wire.

References (10)

  • J. Engler

    Nucl. Instr. and Meth.

    (1983)
  • K. Fujii

    Nucl. Instr. and Meth.

    (1985)
  • K. Fujii

    Nucl. Instr. and Meth.

    (1986)
  • I. Endo

    Nucl. Instr. and Meth.

    (1981)
    N. Awaji

    Nucl. Instr. and Meth.

    (1982)
    J. Chiba

    Nucl. Instr. and Meth.

    (1983)
  • H. Vieau

    Nucl. Instr. and Meth.

    (1984)
There are more references available in the full text version of this article.

Cited by (39)

  • Parton fragmentation functions

    2016, Progress in Particle and Nuclear Physics
  • Measurement of the jet width in γγ collisions and in e<sup>+</sup>e<sup>-</sup> annihilation process at TRISTAN

    1999, Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics
  • Charged-particle multiplicities of quark and gluon jets in e<sup>+</sup>e<sup>-</sup> annihilation at TRISTAN

    1997, Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics
  • Observation of highly virtual photon-photon collisions to hadrons at TRISTAN

    1996, Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics
  • Electron identification using the TOPAZ detector at TRISTAN

    1995, Nuclear Inst. and Methods in Physics Research, A
View all citing articles on Scopus