Validity of using tri-axial accelerometers to measure human movement – Part II: Step counts at a wide range of gait velocities

https://doi.org/10.1016/j.medengphy.2014.02.006Get rights and content

Abstract

A subject-specific step counting method with a high accuracy level at all walking speeds is needed to assess the functional level of impaired patients. The study aim was to validate step counts and cadence calculations from acceleration data by comparison to video data during dynamic activity. Custom-built activity monitors, each containing one tri-axial accelerometer, were placed on the ankles, thigh, and waist of 11 healthy adults. ICC values were greater than 0.98 for video inter-rater reliability of all step counts. The activity monitoring system (AMS) algorithm demonstrated a median (interquartile range; IQR) agreement of 92% (8%) with visual observations during walking/jogging trials at gait velocities ranging from 0.1 to 4.8 m/s, while FitBits (ankle and waist), and a Nike Fuelband (wrist) demonstrated agreements of 92% (36%), 93% (22%), and 33% (35%), respectively. The algorithm results demonstrated high median (IQR) step detection sensitivity (95% (2%)), positive predictive value (PPV) (99% (1%)), and agreement (97% (3%)) during a laboratory-based simulated free-living protocol. The algorithm also showed high median (IQR) sensitivity, PPV, and agreement identifying walking steps (91% (5%), 98% (4%), and 96% (5%)), jogging steps (97% (6%), 100% (1%), and 95% (6%)), and less than 3% mean error in cadence calculations.

Introduction

Physical inactivity is an independent risk factor for chronic disease and disability and is estimated to result in 3.2 million deaths world-wide each year [1]. Regular physical activity has been associated with health improvements in many populations [2]. Many commonly used mobility assessment methods have limitations such as subjectivity [3] or involve clinical-based evaluations that fail to mimic real-world functional requirements, such as the 10 m walk test which underestimates gait velocity predictions in a community setting [4]. It is important to quantitatively assess mobility in the free-living environment as health and wellness measure. This can be accomplished with accurate measurement of step counts and cadence in the home and community.

Step counting is one of the most commonly used measures of physical activity [5]. Sensors can provide objective information on movement while their small size and light weight allow for home deployment. One of the main issues associated with step counts as a physical activity measure is that high accuracy is needed. Many previous studies have assessed the step count and gait event accuracy of pedometers, accelerometers, and gyroscopes [6], [7], [8], [9], [10], [11]. However, limited information on the algorithms and the data analysis methods are provided and the protocols performed are overly simplified, often consisting of long periods of continuous walking which are inconsistent with most daily living activities. The step detection accuracy of many sensors has also been shown to decrease for shorter activity duration and at slower walking speeds [8], [12], [13], [14], particularly in older patients. The need for accurate step counts at slow walking speeds is of critical importance as slow walking speeds can be indicative of movement disorders [15], mobility disability [16], and have been linked to high risk for reduced function, morbidity, and mortality [17]. Increases in walking speed and the ability to vary cadence demonstrate increased function level [18], reduced risk, and higher predictions of survival [17], [19]. While a small number of studies have shown that results from the methods they used are not affected by different walking speeds, accuracy during shuffling, stair climbing, and jogging have yet to be investigated and only limited gait velocity ranges are examined [14], [20], [21]. Furthermore, the use of step counts as a measure of physical activity is limited as the characteristics of the steps are unknown. An activity monitoring system (AMS) capable of identifying walking step counts, jogging step counts, and the ability to vary cadence while walking and jogging can be beneficial as it gives information on an individual's functional level. Furthermore, an objective portable method for the functional assessment of patients, particularly those with slow walking speeds, could serve as a beneficial motivational rehabilitation tool and an effective clinical outcomes measure in the free-living environment.

The aim of this study was to determine the validity and reliability of a custom-designed AMS as an objective adaptive step counter. The algorithm's accuracy was validated with visual step counts and was compared to two commercial step counters (Fitbit Tracker (Fitbit, San Francisco, CA) and Nike+ Fuelband (Nike, Beaverton, OR)) during walking and jogging trials at a range of gait velocities. The validity and reliability of the AMS algorithm were also evaluated for walking and jogging segments in healthy adults during a protocol of simulated free-living dynamic activities in the laboratory by comparison to video recordings.

Section snippets

Experimental design

Accelerometer and video data were acquired from 12 (3 M, 9 F) healthy adults as they performed 7–10 walking/jogging trials in a straight line over an 8.5 m walkway (with additional room to accelerate and decelerate). Subjects wore two different commercial devices (Fitbit monitors on the right lateral ankle and the waist and a Nike Fuelband on the right wrist) in addition to the AMS which consisted of accelerometers below the navel on the waist, on the right thigh lateral midpoint, and bilateral

Results

Eleven of the twelve participants completed the protocol as prescribed. Data from one subject were excluded since the protocol was not followed correctly. The total time to complete the protocol of static and dynamic activities averaged (SD) 359 (42) s and the mean (SD) total number of steps taken was 282 (20).

Discussion

The study aim was to validate an algorithm using an AMS to measure step counts and cadence during walking and jogging for a wide range of gait velocities. There is a need for an accurate objective step counter for patients with slow walking speeds as they would benefit most from a motivational tool capable of accurately monitoring activity increases. The described step detection algorithm incorporates an adaptive acceleration threshold heel-strike detection algorithm capable of managing

Conclusion

While this study involves a simulated protocol conducted in a laboratory environment, the results suggest that the proposed analysis methods are suitable for step counting using tri-axial accelerometers on the ankles, thigh, and waist in a free-living environment.

Acknowledgements

Funding was provided by DOD DM090896, NIH T32 HD07447, and NIH K12 HD065987. The body-worn motion detection and recording units were provided by Dr. Barry Gilbert, James Bublitz, Kevin Buchs, Charles Burfield, Christopher Felton, Dr. Clifton Haider, Michael Lorsung, Shaun Schreiber, Steven Schuster, and Daniel Schwab from the Mayo Clinic Special Purpose Processor Development Group. The information or content and conclusions do not necessarily represent the official position of, nor should any

References (45)

  • L.M. Shulman et al.

    Subjective report versus objective measurement of activities of daily living in Parkinson's disease

    Mov Disord

    (2006)
  • D. Taylor et al.

    Does clinic-measured gait speed differ from gait speed measured in the community in people with stroke

    Clin Rehabil

    (2006)
  • J.R. Thomas et al.

    Research methods in physical activity

    (2005)
  • S.E. Crouter et al.

    Validity of 10 electronic pedometers for measuring steps, distance, and energy cost

    Med Sci Sports Exerc

    (2003)
  • D.W. Esliger et al.

    Validity of the Actical accelerometer step-count function

    Med Sci Sports Exerc

    (2007)
  • G. Le Masurier et al.

    Comparison of pedometer and accelerometer accuracy under controlled conditions

    Med Sci Sports Exerc

    (2003)
  • A. Salarian et al.

    Gait assessment in Parkinson's disease: toward an ambulatory system for long-term monitoring

    IEEE Trans Biomed Eng

    (2004)
  • C.C. Yang et al.

    Real-time gait cycle parameter recognition using a wearable accelerometry system

    Sensors (Basel)

    (2011)
  • B. Dijkstra et al.

    Detection of walking periods and number of steps in older adults and patients with Parkinson's disease: accuracy of a pedometer and an accelerometry-based method

    Age Ageing

    (2008)
  • C.G. Ryan et al.

    The validity and reliability of a novel activity monitor as a measure of walking

    Br J Sports Med

    (2006)
  • K.A. Lowry et al.

    Walking stability using harmonic ratios in Parkinson's disease

    Mov Disord

    (2009)
  • J.M. Guralnik et al.

    Lower extremity function and subsequent disability: consistency across studies, predictive models, and value of gait speed alone compared with the short physical performance battery

    J Gerontol A Biol Sci Med Sci

    (2000)
  • Cited by (118)

    View all citing articles on Scopus
    View full text