Influence of various irradiation processes on the mechanical properties and polymerisation kinetics of bulk-fill resin based composites
Introduction
In an attempt to speed up the restoration process, a new resin-based composite (RBC) material class, the bulk-fill RBCs, was recently introduced on the market, enabling up to 4 or 5 mm thick increments to be cured in one step, thus skipping the time-consuming layering process. The mechanical stability in stress bearing areas of fillings restored with bulk-fill RBCs is still an open question, since long-term clinical studies are not available so far. In vitro studies revealed for bulk-fill RBCs, as a material class, similar flexural strength values as the class of nano- and micro-hybrid RBCs, and significantly higher values when compared to flowable RBCs. The modulus of elasticity, the indentation modulus and the hardness classify this materials as between the hybrid RBCs and the flowable RBCs, while in terms of creep, bulk-fill and flowable RBCs perform similar, both showing a significantly lower creep resistance when compared to the nano- and micro-hybrid RBCs.1 Other studies found, however, that bulk-fill RBCs exhibited a creep deformation within the range of regular RBCs.2
A main concern when curing large increments remains however potentially increased polymerisation shrinkage stress at the tooth-material interface.3, 4 Few studies are available so far to allow a critical assessment of bulk-fill materials placed in deep cavities. Compared to regular flowable and non-flowable nano- and micro-hybrid methacrylate-based RBCs and a silorane-based micro-hybrid RBC, a bulk-fill material in its experimental version (SDR®, Dentsply) revealed the lowest shrinkage stress and shrinkage-rate values in 2 mm (thick) × 4 mm (width) × 4 mm (length) cavities.5, 6 Corroborative to this study, shown bulk-fill flowable RBCs (SDR®, Dentsply; x-tra base, VOCO) significantly reduced cuspal deflection in standardised Class II cavities in comparison with a conventional RBC (GrandioSO, VOCO) restored in an oblique incremental filling technique.7 Moreover, flowable bulk-fill RBCs, like SureFil SDR, are considered to be adequate for both, post cementation and core build-up.8
The alleged changes in the rheology of bulk-fill RBCs compared to regular RBCs that are supposed to allow a better adaption to the cavity walls remained unconfirmed by in vitro microleakage7 and marginal integrity studies.9 The material's reliability however, a characteristic associated with lower surface defects that are able to initiate crack propagation, proved to be very high in low viscosity bulk-fill RBCs (high values for the Weibull modulus), but moderate, and hence comparable to regular nano- and micro-hybrid RBCs in high viscosity RBCs.1 This behaviour proved, indirectly a better adaptability to the cavity (or mould) surface, in low viscosity bulk-fill RBCs. The classification in low and high viscosity bulk-fill RBCs is unambiguously reflected in the mechanical properties1 and determines the application procedure of the materials. Restorations made with low viscosity bulk-fill RBCs (SureFil®SDR®, Dentsply; Venus® Bulk Fill, Heraeus Kulzer; x-tra base, VOCO; Filtek™ Bulk Fill, 3M ESPE) must be finished by adding a capping layer made of regular RBCs, while high viscosity bulk-fill RBCs (SonicFill™, Kerr; Tetric EvoCeram® Bulk Fill, Ivoclar Vivadent; X-tra Fil, VOCO) may be placed without capping.
In vitro studies confirmed that bulk-fill RBCs could be cured in larger increments, as the degree of cure (DC) and the micro-mechanical properties were maintained within 4 mm layers at an irradiation time of up to 20 s (SDR®, Dentsply; Venus Bulk Fill®, Heraeus Kulzer).10 A reason for an enhanced depth of cure is considered to be an increased translucency, due to decreased filler load and increased filler size,1 since the chemical composition and the initiator systems (except for Tetric EvoCeram® Bulk Fill, Ivoclar Vivadent) in bulk-fill RBCs do not consistently differ from regular RBCs.1
An important aspect, often ignored in depth-of-cure-studies, where the light tip of the curing unit is placed directly against the material, is the consistent decrease of irradiance in correlation with the distance from the light tip, which, in a clinical situation, is frequently at least 7 mm.11, 12
This study therefore aims to evaluate the effect of polymerisation time and distance from the light tip on two bulk-fill RBCs – Tetric EvoCeram® Bulk Fill and x-tra base – by assessing their micro-mechanical properties and polymerisation kinetics (variation of the degree of cure), at simulated clinical relevant filling depths.
The tested null hypotheses were that: (a) there would be no significant differences between the two materials in view of micro-mechanical properties (Vickers hardness (HV), depth of cure (DOC), indentation modulus (E)), degree of conversion (DC) or polymerisation kinetics, at any measured depth, irradiation time or distances away from the light tip and (b) within one material, the above mentioned parameters would not influence the measured properties.
Section snippets
Materials and methods
Two bulk-fill RBCs (Table 1) were investigated by assessing DC and micro-mechanical properties (HV, DOC, E) as function of depth (0.1, 2, 4 and 6 mm for DC measurements and 0.1–6 mm in 100 μm steps for E and HV), polymerisation time (10, 20 or 40 s) and distances away from the light tip (0 and 7 mm).
Results
The influence of the material on the measured mechanical properties was significant (η2 = 0.080 for E and 0.256 for HV). The influence of the parameter irradiation time, distance away from the light tip and depth on the measured properties was material dependent, with Tetric EvoCeram® Bulk Fill being more influenced (higher η2 values) by all the above mentioned parameters than x-tra base (Table 3).
The strongest effect on all measured properties was exerted in Tetric EvoCeram® Bulk Fill samples by
Discussion
The results of the present study proved that both analyzed bulk-fill materials – Tetric EvoCeram® Bulk Fill and x-tra base – enable, as described by the manufacturer, at least 4 mm thick increments to be cured in one step under clinically relevant curing conditions similar to other bulk-fill RBCs (SDR®, Dentsply and Venus® Bulk Fill, Heraeus Kulzer).10 Although being a low viscosity bulk-fill RBC material, clinically necessitating a capping layer made of regular RBCs, the measured mechanical
Conclusions
All tested null hypotheses are rejected. The analyzed bulk-fill materials – Tetric EvoCeram® Bulk Fill and x-tra base – enable at least 4 mm thick increments to be cured in one step under clinically relevant curing conditions. However, the susceptibility to variation in irradiance proved to be material dependent, thus properties measured under clinically simulated curing conditions might vary to a different extend from those measured under ideal curing conditions.
References (31)
- et al.
Creep deformation of restorative resin-composites intended for bulk-fill placement
Dental Materials
(2012) - et al.
Polymerization profile analysis of resin composite dental restorative materials in real time
Journal of Dentistry
(2012) - et al.
Bonding of low-shrinking composites in high C-factor cavities
Journal of Dentistry
(2012) - et al.
Investigations on a methacrylate-based flowable composite based on the SDR technology
Dental Materials
(2011) - et al.
Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials
Journal of Dentistry
(2012) - et al.
Post retentive ability of a new resin composite with low stress behaviour
Journal of Dentistry
(2012) - et al.
Marginal quality of flowable 4-mm base vs. conventionally layered resin composite
Journal of Dentistry
(2011) - et al.
New insight into the “depth of cure” of dimethacrylate-based dental composites
Dental Materials
(2012) Properties of a silica-reinforced polymer for dental restorations
The Journal of the American Dental Association
(1963)- et al.
Measurement of opalescence of resin composites
Dental Materials
(2005)
Effect of resin matrix composition on the translucency of experimental dental composite resins
Dental Materials
How filler properties, filler fraction, sample thickness and light source affect light attenuation in particulate filled resin composites
Dental Materials
Light transmission on dental resin composites
Dental Materials
UV–vis spectrophotometric direct transmittance analysis of composite resins
Dental Materials
Benzoyl germanium derivatives as novel visible light photoinitiators for dental materials
Dental Materials
Cited by (124)
Effect of Additional Light Curing on Colour Stability of Composite Resins
2022, International Dental JournalImpact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
2021, Saudi Dental JournalMagnetic Hyperthermia to Promote Acrylamide Radical Polymerizations
2024, ACS Applied Polymer MaterialsA 24-month randomized clinical study of flowable bulk-fill resin composites in Class III restorations
2024, Journal of Clinical and Experimental Dentistry