1 Introduction

Copper and Chromium are the lethal heavy metal pollutants extensively used in different industries [1]. Anthropogenic activities are the major sources of Cu/Cr, for instance, sewage treatment processes, brass manufacturing, petroleum refining, electroplating smelting, mining, coal-fired power stations, metal production, earth's crust, waste incinerators, leather tanning, paint processing, wood preservation and from the application of agricultural chemicals [2, 3]. The two stable oxidation states of Chromium in aqueous environments are trivalent Chromium (Cr(III)) and hexavalent chromium (Cr(VI)) with different toxicities, mobilities, and bioavailabilities. In general, Cr(III) is relatively less toxic than Cr(VI) [4, 5]. Although Copper and Chromium are the fundamental micro-nutrients required by living organisms, beyond their allowable level of Cu(II) and Cr(VI) can make significant changes on human health such as chest pains, vomiting anemia, hypoglycemia, and irritation of the eyes, skin, and nose, stomach intestinal distress pallor, hypoglycemia, stomach abdominal pain, even kidney damage, eardrum perforation, lung carcinoma and eventual death [6,7,8,9,10]. Therefore, the effective methods to remove Cu(II) and Cr(VI) from polluted water and soil are desperately needed. To remove heavy metals from the aqueous phase many techniques have been explored, including electrochemical deposition [11], ion-exchange [12], coagulation, and precipitation [13], solidification [14, 15], membrane separation technology [16], and adsorption. Recently, promising technology adsorption is used for the removal of Cu(II) and Cr(VI) owing to easy operation, high efficiency, relatively low-cost, and insensitivity to toxic substances [17,18,19,20,21,22].

Several low-cost adsorbents such as sugarcane bagasse, rice husk, sawdust, coconut husk, oil palm shell, neem bark, etc., have been used for the removal purpose of heavy metals from wastewater [23,24,25,26,27,28,29]. Nevertheless, the efficiency usually not as efficient as radiation grafted polymers to remove heavy metals. The radiation method is a clean and effective technology to produce grafted polymeric adsorbent (GPA) [30]. ‘Grafting’ is a method where monomers are covalently bonded onto the polymer chains [31]. The desired property of adsorbent with proper mechanical strength can be obtained by this method, without using any harmful poisonous initiator [32, 33]. Available methods of radiation polymerization involve direct irradiation of fiber in monomer solution, vapor phase irradiation method, and pre-irradiation.[30]. Different authors have intensively studied the grafting of acrylic acid onto nonwoven polyethylene (PE) film and some of their attention on the effect of amphoteric properties of obtained grafted nonwoven PE films. Non-woven polyethylene is a low-cost material used for different purposes. Grafting of diallyl dimethyl ammonium chloride (DADMAC)/Acrylic acid (AAc) onto inert polymeric supports (e.g., polyethylene) will make it a better quality of adsorbent with good mechanical strength. The grafting process of DADMAC/AAc is very important in improving the adsorption properties of gamma-ray induced polymeric materials for the removal of heavy metal ions from aqueous solution. The present work has explored a new adsorbent by grafting of binary monomers acrylic acid and DADMAC on nonwoven irradiated polythene sheets. Then the prepared GPA was characterized using Fourier Transform Infra-Red (FTIR), Scanning Electron Microscopy (SEM), and Thermogravimetric Analysis (TGA) to understand molecular interaction, surface morphology and physical phenomena of them. The prepared GPA had strengthened mechanical properties due to increased crosslinking of it. The parameters influencing the adsorption process were optimized including reaction time, pH, initial concentration as well as temperature on the adsorption of Cu(II)/Cr(VI). Therefore, the synthesized GPA was implicated in the removal of copper and chromium ions to understand the adsorption potential of the polymeric composite using radiation.

2 Materials and methods

2.1 Materials

Nonwoven Polyethylene, AAc (purity 98.5%), and DADMAC 65% in water were procured from Kurashiki MFG Co. Ltd; Guangdong, 515,021, China; and Fluka Chemie AG CH-9470 Buchs, respectively. Copper Sulfate and Potassium Dichromate salt were purchased from E. Merck Darmstadt, Germany, and Techno Pharmachem, India, respectively. Hydrochloric acid (purity 37%), acetone (purity 99.5%) were collected from Merck KGaA 64,271 Darmstadt, Germany. Sodium hydroxide was received from Merck Limited, Mumbai.

2.2 Instruments

Electrical Balance (Model AR 1140, supplied by SMH Engineering and Trading Co., Dhaka, Bangladesh.), Gravity convention oven (supplied by Memmert UM series, temperature range 30-220ºC.), Vial, pH Meter (Model: Cole-Parmer-5991–81 FIB-12, supplied by Institute of Electronics, AERE, Dhaka, Bangladesh.), Volumetric flasks (25, 50, 100 and 500 mL), Test tube, Beaker, crucible, Micro Pipettes, Filter paper (Whatman Grade 42 ashless quantitative filter papers), Funnel, Filtration stand, Digital Caliper (Dimensions of PE films were measured in digital caliper.), Water Bath, Atomic Absorption Spectrophotometer (Model: Atomic Absorption Spectrophotometer was AA-6800 and supplied by SHIMADZU, Japan), Cobalt -60 radiation, Gamma radiation source, (Model: GSCIE -11), FT-IR Spectrophotometer (Model: AIM-8800, supplied by SHIMADZU, Japan.) were used in this study.

2.3 Preparation of grafted polymeric adsorbent

Non-woven polyethylene sheets (thickness 0.04 mm) were collected from Kurashiki MFG Co. Ltd. The sheets were cut into small pieces of 10 cm length and 1.5 cm width and then taken 6 pieces to do this experiment. Then the pieces were marked as 1 to 6 and put them in a packet. The non-woven PE films were irradiated using the Co-60 gamma radiation source at 50 kGy radiation dose at ambient temperature. The irradiated PE films were preserved at dry-ice condition until further use. The monomer solution was prepared by the addition of 20 g DADMAC and 20 g AAc to 110 mL distilled water. The monomers and distilled water were taken in a beaker, heated 700C on a hot plate for half an hour to make a clear solution. Then the solution was placed in the gas passing bottle. Argon gas was passed for one hour. The monomer solution was bubbled with argon gas for the removal of dissolved oxygen. The 6 pieces of previously irradiated nonwoven PE films were taken in a tube and immediately 70–75 mL of the deaerated monomer solution were poured into the tube. After filling the tube with monomer solution, it was closed with a lid for avoiding intrusion of oxygen from the air into the monomer solution. Next, the grafting reaction was carried out at 80 °C for 4 h in a water bath. The GPA had utmost grafting yield of 192% with reaction time 4.0 h at 50 kGy. Then the grafted non-woven PE film was appropriately washed. After washing and drying, it will be ready to use in the experiment.

2.4 Preparation of copper ions solution

1.97 g CuSO4.5H2O was weighted in digital balance and took in a 500 mL volumetric flask. Then the flask was filled with distilled water up to the mark. Thus 1000 ppm of Cu(II) ion solution was prepared. Then 0.5 ppm, 1 ppm, 3 ppm, 5 ppm, 10 ppm, and 15 ppm were made from the stock solution of Cu(II). On the other hand, 1.41 g of K2Cr2O7 was weighted and took in a 500 mL volumetric flask. Then the flask was filled with distilled water and prepared 1000 ppm of Cr(VI) ion solution. Then 0.05 ppm, 0.1 ppm, 0.5 ppm, 1 ppm, 3 ppm, 5 ppm, 10 ppm, and 15 ppm solutions were prepared from the stock solution of Cr(VI). The prepared solutions were reserved at room temperature before testing and used to make the standard calibration curve in Atomic Absorption Spectrophotometer.

2.5 Sample preparation for AAS

The vials were used to take 25 mL copper/chromium ion solution to prepare sample for AAS analysis. A piece of grafted non-woven PE film was put into the metal ion solution in which initial concentration was known. After keeping the prepared adsorbent in desired conditions for a definite time, the solution was taken for AAS analysis to measure the final concentration of the solution. The physical appearance of grafted films were shown in Fig. 1, after adsorption of Cu(II) and Cr(VI) ions.

Fig. 1
figure 1

Grafted filma before,b after Cu(II), b after Cr(VI) adsorption

2.6 Determination of adsorption capacity of metal ions

Atomic Absorption Spectrometry (AAS) is a prevalent and reliable technique for detecting metals and metalloids in environmental samples. The total metal content in solution and GPA samples was measured by Atomic Absorption Spectrometry. At first, a typical set of standard calibration curves with good linear regression and better relative standard deviations were attained. The adsorption was explored by adding a weight piece of GPA into 25 ml of 1000 ppm metal solution (pH 4.84 (Cu) and 1.5 (Cr)) at room temperature (27 °C) for the study of adsorption kinetics. In contrast, for the study of adsorption isotherms the adsorption was explored by adding a weight piece of GPA into 25 ml of different concentration (200–1000 ppm) of metal solution (pH 4.84 (Cu) and 1.5 (Cr)) at room temperature (27 °C). On completion of adsorption, the spectrophotometry was used to determine metal ions content in the resultant of sample. The metal adsorption capacity was calculated according to the following Eq. 1.

$$Metal\text{\hspace{0.17em}}adsorption\text{\hspace{0.17em}}capacity=\left(V\left({C}_{0}-{C}_{e}\right)\right)/W$$
(1)

where, V = Volume of the Cu(II)/Cr(VI) solution in L; W = Weight of GPA in g; C0 = Initial concentration (mg/L) of Cu(II)/Cr(VI) in ppm before adsorption; Ce = Concentration (mg/L) of Cu(II)/Cr(VI) in equilibrium.

3 Results and discussions

3.1 Characterization of PE and GPA

The FTIR analysis was explored to identify the embedded compounds DADMAC and acrylic acid (AAc) on PE sheet. Grafting of DADMAC/acrylic acid (AAc) was introduced on pre-irradiated PE films using γ radiation. Figure 2 shows the FTIR spectrum of films PE and PE-AAc-DADMAC. The FTIR pattern of PE showed the main characteristic peaks at about 2911, and 2845 cm−1 is assigned to C-H asymmetric and symmetric stretch from methylene groups, respectively. Another absorbance bands can be observed at 1464 cm−1 associated with C-H bending vibration and 720 cm−1 associated with C–C rocking vibration. On the other hand, Fig. 2. also exhibits peak observed at 1721 cm−1 peak to carbonyl bond of AAc and other peaks at 1449 cm−1 and 2924 cm−1; those are the fundamental frequency for CH3 and CH2 bending vibrations of DADMAC. Therefore, the above analysis confirms the addition of DADMAC and AAc on the PE sheet. In literature, Ali said (2005) [34] reported that a peak was assigned at 1720 cm−1 for the carbonyl bond of AAc and Kwak et al. (2016) [35] and Pirgalıoglu et al. (2015) [36] found CH3 and CH2 bending vibrations of DADMAC at 1474 cm−1 and 2900 cm−1.

Fig. 2
figure 2

FTIR Result of PE and PE-AAc-DADMAC

Figure 3a and b show the Scanning Electron Microscopy images of nonwoven PE and PE-AAc-DADMAC to compare the physical appearance, respectively. The surface morphology of bared PE film shows a normal or regular shape and diameter of fibers. On the other hands, the SEM image of AAc/DADMAC onto nonwoven PE displays a significant change in shape and also a slight increase in the average diameter of fibers that offer additional physical shreds of evidence of the grafting compare to bare PE films.

Fig. 3
figure 3

SEM image of a PE,b PE-AAc-DADMAC

The thermal stability and decomposition pattern of PE and PE-AAc-DADMAC films were investigated by the thermogravimetric analysis (TGA) and presented clear differences of the thermal stability of them in Fig. 4. TGA of PE showed a one-stage characteristic thermogram. It exhibits thermally stable up to temperature 220 °C. A resilient weight loss of above 90% was observed of PE films owing to the decompose of PE backbone over 220 °C to around 600 °C. On the other hand, four decomposition stages appeared for PE-AAc-DADMAC film in TGA analysis. At temperature steps 75–120 °C, 200–365 °C, 400–479 °C, and above 479 °C; followed the order of weight loss 5.5% shows lower H2O content in the grafted sample, 62% may be due to decomposition of PE and functional group DADMAC, 87% and above 90% weight loss indicating the decomposition of the grafted polymer backbone, respectively. The TGA curves confirms the lower thermal stability of PE-AAc-DADMAC when compared to PE may be attributed to the low thermal stability of DADMAC.

Fig. 4
figure 4

TGA Results of PE and PE-AAc-DADMAC samples

3.2 Adsorption capability of the synthesized composite films for Cu(II)/Cr(VI)

Figure 5 shows the adsorption capacity of prepared composite grafted film from AAc, DADMAC on PE sheet with pH 1 to 5.3. It shows that the pH effect on Cu/Cr adsorption by PE-AAc-DADMAC film was significant. The pH value from 1 to 4.84, the adsorption ability of the GPA enhanced with pH. Nevertheless, the adsorption capacity of GPA declined when the pH range above 4.84 may be owing to solubility loss of adsorbent for Cu(II). On the other hand, the adsorption capacity of Cr(VI) was utmost at pH 1.5 and beyond this, the capacity was decreased. Therefore, the removal capacity for Cu/Cr of PE-AAc-DADMAC in acidic conditions was better as shown in Fig. 5 and was highest at pH 4.84 (Cu) and 1.5 (Cr). The best adsorption capacity was obtained 150.36 mg.Cu/g and 17.34 mg.Cr/g for pH 4.84 and 1.5 respectively, and 1000 ppm metal ion solution at room temperature. In literature, Yue et al. [37] also reported that the adsorption capacity of synthetized adsorbent was high in acidic medium to adsorb metal ions.

Fig. 5
figure 5

Effect of the pH values on the adsorption capacities of GPA for Cu/Cr removal

Different concentrations of Cu(II)/Cr(VI) solutions such as 200 to 1500 ppm were prepared for adsorption ability checked that shown in Fig. 6. The removal ability of the GPA for copper/chromium was enhanced with the increase of the initial concentration of the metal ion because of a high concentration gradient formed between Cu/Cr solution and GPA surface. The adsorption capacity has achieved a plateau (153.89 mg.Cu/g and 17.34 mg.Cr/g) at 1000 ppm of metal ion at pH 4.84(Cu) and 1.5(Cr) for contact time 24 h at room temperature. Moreover, a reduced amount of adsorption occurred when the concentration increased above 1000 ppm due to almost filled up of active sites inside GPA. Similar trend was found in different published papers such as Yue et al. [37].

Fig. 6
figure 6

Effect of the initial metal concentration on the adsorption capacities of GPA

Figure 7 shows the effect of time on the adsorption capacities of Cu (II) by the GPA. Here adsorption capacities increased rapidly with the increase of the time from 1.5 to 5 h. Then the adsorption process becomes slow with the increase of time from 5 to 24 h until the equilibrium condition reached. The equilibrium adsorption capacity of GPA to uptake Cu (II) was 153.89 mg.Cu/g and 17.34 mg.Cr/g after 24 h with pH 4.84(Cu) and 1.5(Cr) at room temperature of 1000 ppm solution. Rahman et al. [38] reported that the adsorption equilibrium condition reached for metal ion removal on polymeric composite with contact time 72 h.

Fig. 7
figure 7

Effect of contact time on adsorption capacity of GPA

The adsorption capacity concerning the applied temperature was shown in Fig. 8. The Cu/Cr removal ability of GPA was enhanced with the increase in the applied temperature imply it was an endothermic process for GPA to adsorb Cu/Cr. In this study, we used the temperature range from 25 °C to 80 °C for Cu/Cr adsorption. The utmost value of adsorption was 141.48 mg.Cu/g and 13.60 mg.Cr/g for 1000 ppm initial metal concentration at 80 °C with pH 4.84(Cu) and 1.5(Cr) for contact time 5 h. The findings of this study closely agree with Yue et al. [37] and they used 1,6-hexanediamine modified magnetic chitosan as an adsorbent to remove metal ions. They observed the best adsorption capacity was achieved at 40 °C of experimental range from 20 °C to 40 °C.

Fig. 8
figure 8

Effect of the temperature on the adsorption capacities of GPA

3.3 Adsorption isotherm models

The experimental data from the process of adsorbing Cu(II)/Cr(VI) by using GPA were analyzed by Langmuir and Freundlich isotherms to get the relationship between the adsorbate on the surface of the GPA and adsorbate in the liquid phase. The former isotherms assume homogeneous process while the latter takes up a heterogeneous system that can be express as following Eqs. (2) and (3), respectively.

$$\frac{{C}_{e}}{{Q}_{e}}=\frac{{C}_{e}}{{Q}_{max}}+\frac{1}{{Q}_{max}B}$$
(2)
$$log {Q}_{e}=log k+\frac{1}{n}log {C}_{e}$$
(3)

where Ce (mg/l) and Qe (mg/g) represent the content and quantity of Cu(II)/Cr(VI) when the adsorption reaches equilibrium. The B, k, and n indicate Langmuir factor (l/mg), Freundlich factors, and Adsorption intensity, respectively. Furthermore, Qmax (mg/g) represents the maximal adsorption amount and exhibits negative value for Cu adsorption comply disagree with Langmuir isotherm. Nevertheless, results exhibit the adsorption data of Cu well fitted with Freundlich isotherm. The adsorption phenomena using obtain data were best fitted with Langmuir isotherm in case of Cr adsorption (with correlation coefficient R2 = 0.99) that present in Fig. 9. compared to Freundlich. The regression correlation coefficient and other factors value were listed in Table 1. Bankole et al. [40] have presented isotherm parameters on the adsorption of the selected heavy metals by P-CNTs and found negative isotherm parameters for few metals.

Fig. 9
figure 9

Adsorption isotherm model (a) Langmuir (b) Freundlich

Table 1 The adsorption isotherm and kinetic models parameters for Cu and Cr by GPA

3.4 Adsorption kinetic models

The measured data of adsorption of Cu(II)/Cr(VI) ions on the GPA was modeled by two kinetic models as Pseudo-first order and Pseudo-second order and shown in Fig. 10. The correlation coefficients (R2) of these two kinetic models were evaluated and chosen one as the better fitted. In this study, a higher R2 = 0.99 value was obtained for the Pseudo-second order kinetic studies that imply better description ability of adsorption kinetics. The Pseudo-first order and Pseudo-second order kinetic models were fitted using measured data by the following Eqs. (4) and (5), respectively.

$$\mathit{log}\left({Q}_{e}-{Q}_{t}\right)=log{Q}_{e}-{(k}_{1}/2.303)t$$
(4)
$$\frac{t}{{Q}_{t}}=\frac{1}{{k}_{2}{Q}_{e}^{2}}+\frac{t}{{Q}_{e}}$$
(5)

where Qe and Qt denote adsorption amount (mg/g) at equilibrium and time t (h), respectively. k1 and k2 indicate the first and second-order kinetic constants, respectively. The kinetic parameters and correlation coefficient (R2) were attained by linear fitting the experimental data listed in Table 1. Moreover, the overall process for adsorbing Cu(II)/Cr(VI) by GPA film followed the pseudo-second-order equation. In addition, comparative study of the maximum adsorption capacity for Cu(II)/Cr(VI) removal in this study with previous researches have shown in Table 2.

Fig. 10
figure 10

Adsorption kinetic model (a) Pseudo-first order (b) Pseudo-second order

Table 2 Adsorption capacity of different adsorbent for Cu(II) and Cr(VI) ion removal

3.5 Reusability of GPA

The reusability of GPA is essential to enhance the cost-effectiveness of the adsorption process for multiple adsorption–desorption steps. The present study observed the reusability of adsorbent to remove Cu(II)/Cr(VI) from solution. The desorption of Cu(II)/Cr(VI) from the GPA films was carried out using 1 M HCl and 1 M NaOH, respectively. Results indicate the acidic medium can facilitate the desorption of Cu(II)/Cr(VI) from GPA. After desorption, the GPA films were washed with distilled water and reused. The films showed no significant loss of activity during reuse. The repeated regeneration gradually decreased the removal capacity of Cu(II) 153.89 mg/g to 125.54 and Cr(VI) 17.34 to 8.97 mg/g shown in Fig. 11. However, the reduction in adsorption capacity may be owing to the decrease in surface area and pore volume, and the relatively weak active site.

Fig. 11
figure 11

Reusability of GPA

4 Conclusions

The grafted polymeric adsorbent (GPA) was successfully synthesized using diallyl dimethyl-ammonium chloride (DADMAC) and acrylic acid (AAc) embedded non-woven irradiated polythene sheet. The molecular interaction, surface morphology, and physical phenomena of synthetized GPA were supported by FTIR, SEM, and TGA. The results of the above analysis convey evidence of successfully made of a composite film comprising DADMAC and AAc on the PE sheet. Effect of pH, initial metal concentration, contact time, and applied temperature on adsorption capacity of Cu(II)/Cr(VI) were investigated batch-wise and found similar trend relating literature. The optimum conditions were pH 4.84(Cu), and 1.5(Cr), 1000 ppm initial concentration, 24 h contact time to acquire maximum Cu(II)/Cr(VI) removal efficiency. The adsorption isotherm data fitted well with Freundlich for Cu and Langmuir for Cr, implying that the models can be applied to remove Cu/Cr by GPA. On the other hand, Pseudo-second-order kinetic model was favored than first-order owing to the best fitting with R2 = 0.99 of measured data. In conclusion, the GPA can be considered as an excellent adsorbent for heavy metal removal from wastewater due to good adsorption capacity, low cost, and reusability.