1 Introduction

Flooding phenomena (FP) is an abnormal problem in the separation of products in refineries [1,2,3]. The FP occurs inside the distillation column when the volume of the stream of vapors that travel up and liquids flow down do not equalize and the balance of mass transfer on trays is disrupted. Vapor/liquid contact is facilitated in the trays of the distillation trays column (DTC). In other words, the equilibrium between liquid evaporation and vapor condensation is balanced using the trays [4, 5]. There is a simple rule that should be obeyed for the design of any distillation column; the stream vapors traveling upward and the liquids leaving downward from each tray of the column, must be equal. Any reasons that cause high liquid loads in trays will increase the risk of FP and negatively affect the performance and maximum capacity of the column. Indeed, during FP on the DTC, liquids are heavily accumulated in trays and prevent the vapors from traveling upward in the column [1,2,3]. FP is generally caused by spray entrainment flooding and froth entrainment flooding mechanisms. Those mechanisms may occur through down-comers malfunctioning and design defects in large diameter columns [1]. The occurrence of FP on the vacuum distillation trays column (VDTC) is also revealed by increased pressure inside the column which significantly decreases the purification efficiency of products [3]. A method for detecting flooding in a distillation column was invented by Pihlaja and Miller and the required devices were made to detect the differential pressure signal, filter the signal, and indicate the flooding generated in the distillation column [6].

The packed distillation column (PDC) is a common beneficial distillation setup that can be used instead of the tray distillation method to improve the separation yield of isotope components in a fluid mixture. The advantages of PDC in comparison with VDTC are that more vapor/liquid contact, as well as offering a lower pressure drop for a better separation in a distillation column. The essential difference between these separation methods is that the vapor/liquid contact in a PDC is continuous, rather than stepwise, as in a VDCT.

The computation and modeling of the fluid behavior inside PDCs have been reviewed by Amini and Nasr Esfahany [7]. The wire gauze structured packing, as an efficient system to evaluate the performance in distillation column, was carried out to study the mass transfer characterization in a PDC [8,9,10]. The influence of the application of nano-refrigerant particles was investigated on the mass fraction, flow rate, vapor quality parameters and boiling heat transfer coefficient within flattened pipes in a fabricated experimental system [11]. Additionally, application of nanoparticles with the goal of enhancing heat transfer in an energy storage unit was studied [12].

Coal tar (CT) is a black, high-viscosity liquid that is a byproduct of coke processing via natural coal (2–8%W water content) heating processes in steel plants [13,14,15,16]. To coke the coal, natural coal is heated inside a special reactor, called a battery, at 1100–1200 °C for 15 h under an Argonne atmosphere. The CT vapors (300–350 °C) are vacuumed by liquid ring pumps and condensed as a liquid product. The coking unit of the Esfahan steel plant factory is the source of the raw CT used for the VDTC of the refinery. There are several properties of crude CT including density and water percentage, that should be considered for the use of CT as a raw material in industry as well as the distillation process. Those mentioned properties are characterized and monitored by the quality control lab of the steel plant at the beginning and before storage in supply tanks [17,18,19] of which, some significant properties and their acceptable ranges of the crude CT are reported in Table 1 and compared with the National Iranian Oil Company standards for the crude oil feed [20].

Table 1 Properties of crude coal tar as a product of the coking unit of the Esfahan steel plant factory in comparison with the National Iranian Oil Company standards for the crude oil feed using in the refinery and their acceptable ranges

The composition of CT contributes heavily to the quality of the CT that is used in industry. Therefore, CT products may be classified into different grades based on their chemical contents and the density of the crude CT. Accordingly, four different grades of CT are produced by coking unit of the Esfahan steel plant factory that is used as inlet CT feeds of the refinery as listed in Table 2.

Table 2 Classification of coal tar product of the Esfahan steel plant factory based on chemical contents (in %W) and density (in Kg m−3) that as used inlet feeds in the refinery

The water content and the density are two extremely important properties of the crude CT that must carefully controlled before any usage as an inlet feed of refinery. Acceptable ranges of those important parameters have been defined by the refinery designer company through the American Society for Testing and Materials (ASTM) and other standard methods. The mentioned acceptable ranges of density and water percentage of crude CT for the refinery are 1100–1250 kg m−3 and 1–3%W, respectively.

Due to the risk of explosion, the excess water of out-of range CT must be eliminated before distillation in the column. To reduce the water, crude CT is pumped to the dehydration unit which converts it to the suitable CT. Another important property for crude CT is coke content. The presence of insoluble particles in crude CT is the main reason for sediment accumulation on trays. The particles precipitate specifically on seal pan areas and the down-comers of the column.

Determining quinoline insoluble (QI) and toluene insoluble (TI) parameters are two common experimental methods to control the capacity of insoluble particles in crude CT [13,14,15]. Moreover, the measurement of the coking value (CV) factor is a well-known test that is usually employed to determine the amount sedimentation of coke for crude CT [21,22,23].

For reducing the sedimentation of unreacted natural coke and values insoluble particles of CT, out-of range crude CT liquid is transferred to a mechanical filtering process unit. Figure 1 reveals the flow transferring process from the CT vapor to the distillation column using a filtration centrifuge process [24,25,26,27,28].

Fig. 1
figure 1

Storing a coal tar liquid with an acceptable insoluble particles value (pathway 1) and an out-of range crude tar liquid after a centrifuging step (pathway 2) in a coal tar tank

Due to the thermal cracking of high molecular weight components that are present in CT [29,30,31], the distillation process is accomplished under vacuum below 300 °C. The advantages of vacuum distillation processing are increasing relative volatilities at lower pressures and reducing the temperature requirement at lower pressures in the system [32, 33].

The CT feeds to the VDTC from E position on tray number 15 at 110–120 °C (Fig. 2). While, the CT temperature at the bottom of VDTC is designed for 231.7 °C (T position), CT has been pumped to H heat exchanger through P centrifuge pumps [34,35,36] to H heat exchanger and it heat up to 250 °C [37,38,39,40]. The Shell & Tube condenser A [41,42,43,44] condenses the CT vapors to CT liquid by injecting fresh water at D position. Critical pressure condition of column is designed for -390 up to -420 mbar. The vacuum pressure is controlled at C position of the VDTC that provides by F liquid ring pumps [45,46,47,48]. The output product of distillation exits from B position of the VDTC.

Fig. 2
figure 2

Schematic of vacuum distillation tray column on a refinery in the middle region of Iran

2 Methods

2.1 Quinoline insolubility parameter

Based on ASTM (D 2318-15) and ANSI/ASTM (D 4746-1998) standards, approximately 1.5 g of CT is poured into an Erlenmeyer flask and dissolved with 50 mL quinoline [49, 50]. The collection is then placed in a Binder model oven Fig. 3a at 80 °C for 20 min. Following weighting CT and quinoline samples from the oven is poured onto filter paper (Watman number GF/C, 70 mm) and connected to a round-bottom flask under vacuum (Fig. 3b). In principle, the vacuum conditions speed up the sedimentation of the sample on to the filter paper and will increase the filtration process efficiency. After filtering the sediment, they are oven heated at 110 °C for 2 h and weighed when cooled.

Fig. 3
figure 3

Equipment used to measure the insolubility of CT in quinoline and toluene and coke value; oven modeling Binder (a), equipment of vacuum package included round-bottom flask and vacuum pump (b), electric heat furnace (c)

2.2 Toluene insolubility parameter

Experimental testing of insolubility of toluene in CT, in accordance with ASTM (D 4072-98) and ANSI/ASTM (D 4072-98) R2004 standards, is likely to be insoluble in quinoline. At first 2 g of CT and 100 mL of toluene is poured in the Erlenmeyer flask and left in the oven for 30 min at 150 °C [51, 52]. Also, the cooling time decreased from 2 to 1.5 h. Equation (1) is used to determine the insolubility parameters of the CT in quinoline and toluene.

$$ {\text{Insolubility Parameters}} = \frac{{{\text{W}}_{2} - {\text{W}}_{1} }}{{{\text{W}}_{\text{t}} }} \times 100 $$
(1)

w1, w2, and wt introduce initial weight of filter paper, filter paper and sediment weights, and the initial weight of CT in %W, respectively.

2.3 Coking value factor

According to ISO (6998-97) standard, the amount of CT (2 g) is poured in crucible which is a weighted and placed in the preheated oven, then placed in a small nickel crucible. The sides of crucible are filled with coking particles to properly direct the heat off the furnace of crucible body and prevent thermal mutation error. Crucible with the small nickel crucible is placed in an electric heat furnace at 550 °C for 2.5 h (see Fig. 3c). Then the small nickel crucible and crucible is removed from the electric furnace. After cooling, the crucible containing coke particles also weighed [53]. Equation (2) is used for determining of CV in CT.

$$ {\text{Coking Value}} = \frac{{{\text{W}}_{2} - {\text{W}}_{1} }}{{{\text{W}}_{\text{t}} }} \times 100 $$
(2)

In the equation above w2 is the weight of crucible and the coking particles involved, w1, is the initial weight of crucible where wt is the initial weight of CT (%W). The approved ranges and related standard measurement methods for QI and TI parameters and CV factor are presented in Table 3.

Table 3 Approved ranges for quinoline insoluble and toluene insoluble parameters and coking value factor

Figure 3 shows the laboratory equipment used in this study to measure the insolubility of CT in quinoline and toluene and CV:

3 Results and discussion

3.1 Analysis on data of coal tar quality determination

Data from recorded values for QI, TI parameters in CT and CV factor of before and after centrifuging [22,23,24,25,26,27,28] are collected in period of receiving coal feed inlet to distillation column in the years 2017–2018 was gathered (Table 2). These results are for two different feed samples of differing quality classified as received from batteries 1 and 3 of the steel plant. In general, the feed quality received from battery 1 was always higher than that of battery 3 of steel plant. The difference in feed quality depends on to the heating conditions of coal and the condensation of vapors of CT [17,18,19]. The type of coal used in the steel plant was constant during this period.

In order to analysis the effects of using centrifuges for the feeding of CT on the VDTC, the recorded data in Table 4 are plotted in Fig. 4. The variation of QI, TI, and CV parameters belonging to each sampling number, before applying a centrifuge step on the feed to the distillation column, shown in diagrams (a), (b), and (c) of the figure, respectively.

Table 4 Recorded data for the insolubility of quinoline solvent, toluene solvent in coal tar for batteries 1 and 3 and coke value factor within 2 year
Fig. 4
figure 4

The parameters of quinoline insoluble (a), toluene insoluble (b) and coking value (c) in entrance coal tar feed to distillation column for batteries 1 and 3 in 20 days

It can be seen from Fig. 4 and Table 2 in diagrams (a, b, and c) from samples 1 to 7, the parameters of QI, TI, and CV for CT feed have been placed in suitable bounds which indicates the received CT quality from the steel plant is proper. Thus, it is obvious that the received CT feed of battery 3 lower quality than battery 1. In sample number 8, a significant increase in weight percent of quinoline and toluene insolubility parameters and CV were observed. In particular, the slope of the increasing trend was more noticeable for the insolubility parameters of quinoline and toluene. This increase in weight percent (%W) in insoluble sediments is more significant for the insolubility index of toluene than quinoline. Lower quality of CT feed inlet to distillation column from battery 3 of steel plant, due to sudden jump of these indices between sample 7 and 8. The upward trend of these indices in samples 8 to 15 continues, with samples above 30 likely to have the distillation column near critical conditions. Thus, the distillation column was shut down in sample 25 and put out of service (overhaul). During the six-month overhaul period, the distillation column of 25 samples of CT feed to the refinery were carried out in depot storage tanks. During this period, CT storage tanks were sampled at 4–day intervals. The samples were centrifuged at a speed of 2000 rpm, equivalent to the operating conditions of the centrifuge used in the refinery [24,25,26,27,28] After performing a centrifugation step in the laboratory, the insoluble parameters of quinoline and toluene solvents and the coke content in the depot CT feed from batteries 1 and 3 were determined, the results of which are shown in Fig. 5.

Fig. 5
figure 5

Parameters of quinoline insoluble (a), toluene insoluble (b) and coking value (c) measured in depot coal tar feed from batteries 1 and 3 after applying a centrifuge step in the laboratory for 4-days

Consequently, after centrifuging at 2000 rpm on the CT feed to the distillation column, it was observed that the insolubility parameters of quinoline solvent and toluene solvent in CT and the amount of CV, in diagrams (a, b, and c) of samples 26 to 38, had a noticeable decreasing trend and are in the permissible range again.

3.2 Select the suitable tray in vacuum distilled column

During the overhaul process, intense accumulation of coke containing sediments was observed in the distillation column. However, the bulk of these sediments accumulated on trays number 11 and above, especially in the down-comer and seal pan areas of the trays [4, 5]. The accumulation of coke containing sediments on tray 22 indicated the intensity of coke deposition in the movable valves of the seal pan tray, which is illustrated in Fig. 6a, b.

Fig. 6
figure 6

Tray number 22 vacuum distillation column with 30 mm depth and 25 mm diameter movable valves (a, b), new design on tray number 22 by removing seal pan and inserting 40 mm diameter fixed valves (c)

Due to the over accumulation of coke containing sediments in the tray valves, Fig. 6a, b seal pan areas observed during the overhauling of the distillation column, changes to the tray designs were decided upon. For this purpose, to minimize sediment accumulation, the first removable tray valves with fixed valves, having the highest resistance to deposition, were replaced. In addition, the diameter of the valves also increased from 25 mm to 40 mm to minimize the accumulation of sediments, this also facilitates passage of the vapor phase through the liquid phase (Fig. 6c). Observations made during the overhaul revealed that one of the main factors for sediment accumulation on distillation trays, the input feed CT is capability for forming sediments is the seal pan in the down-comer area. In fact, the 30 mm depth of the seal pans Fig. 6b was a suitable place for sediment accumulation. Figure 7a shows the difference between a seal pan tray and tray without seal pan Fig. 7b in the formation and accumulation of coke containing sediments.

Fig. 7
figure 7

Demonstrate the movement of the liquid phase downward and the vapor upward in the distillation column and how coke containing sediments accumulate on the seal pan trays (a) and no accumulation of sediment on the trays without seal pan (b)

In the new design, the trays used to minimize the accumulation of coke containing sediment were removed from the seal pan tray. In case of accumulation of sediments on the tray, the flow of liquid downstream would wash the sediments away. This way the duration of overhaul will be greatly reduced. After 6 months of working with the distillation column with the corrections made, the vacuum pressure top of the distillation column was again in the range of − 390 to − 420 mbar. Meanwhile, the vacuum pressure top of the distillation column was reduced to -230 mbar prior to the before making the above-mentioned corrections.

After completing the overhaul operation on the vacuum tray distillation column and replacing trays without seal pan instead of seal pan trays while also increasing tray diameter from 25 to 40 mm, it was decided to be in service three months later. Taking the distillation column data on vacuum pressure recorded above the tower and comparing them with the values recorded before the overhaul operation. The decision was made 3 months after the distillation column was put into service, vacuum pressure data from the top of the column is recorded and compared with those recorded before the overhaul operation. For this purpose, using the data recorded in Table 3: Fig. 8a for vacuum pressures recorded after correction and centrifuging process on the CT feed inlet to the distillation column and Fig. 8b for vacuum pressures recorded before overhaul operation was drawn. The comparison between the two graphs shows how vacuum pressure drops at the top of the distillation column range from − 400 to − 230 mbar due to the heavy accumulation of coke containing sediments on the trays Fig. 8b. and then how to improve vacuum pressure from − 240 to operating range − 410 mbar shows due to the necessary modifications 3 months after the distillation column was put into service, which resulted in a significant decrease in sediment accumulation Fig. 8a.

Fig. 8
figure 8

Improvement the vacuum pressure of the distillation column during the 4 months before and 3 months after the overhaul and the centrifuge process on coal tar feed (a, b). Reduction of TI, QI and CV parameters after centrifugation on feed coal tar inlet to distillation column over 9–day intervals (c)

On the other hand, in the 10 cases sampled (50 to 60) during the 3 months after the overhaul operation, as well as one centrifugation step on CT feed to distillation column, the method to reduce the insolubility parameters of quinoline and toluene solvents in CT and the CV was continued and reported for both battery 1 and battery 3 in Fig. 8c. From the results visible in the figure we can see that 3 months after overhaul, the weight percent of QI, and TI parameters in the distillation column for both batteries are almost constant and are within the permissible range provided in Table 3. In addition, the CV is slightly reduced which indicates that the centrifuge process is successful in improving CT feed quality as the input to the VDTC.

Although the CT centrifuge process is an excellent method to reduce of the coke sedimentation in the VCDT, it is a costly method and needs to add many expensive industrial facilities beside the distillation systems. Thus, the main strategy of this research is in the control of the QI, TI parameters and the CV to avoid centrifuging all the crude coal tar feeds before submitting it to the VCDT.

4 Conclusion

The flooding phenomena in the vacuum distillation trays column under study was due to the accumulation of coke containing sediments particularly in the areas of movable valves and seal pans tray number 11 or higher, as examined at the refinery. The feed quality of coal tar inlet to this distillation column was evaluated by the insolubility parameters of the quinoline solvent, the toluene solvent, and the coking value. For a one-year period, the results of the quinoline and the toluene insolubility experiments were increased respectively by 10 and 6 times while the coking value was raised 50–60%. This indicates the necessity of using a centrifuge before the feed coal tar inlet to the distillation column. Consequently, the vacuum pressure top of the distillation column was reduced from − 230 to the range of − 390 to − 420 mbar that could be taken as a clear sign of the flooding phenomena in the tower. In order to reduce the accumulation of coke sediment on the trays, modifications were made to the design of the tower: replacement of the 25 mm removable valves with the wider fixed valves (40 mm diameter) and removing the seal pans from the trays in the distillation column. After these modifications, passage of the vapor phase through the liquid phase is facilitated and the coke sediments on trays and down-comer areas of the column were simply flashed down. Thus, sudden increments of vacuum pressure were no longer observed during the 3 months of service of the vacuum distillation trays column. Moreover, the weight percent of quinoline and toluene insolubility parameters and coking value in coal tar do not climb as experienced before the centrifuging process and the distillation column manipulation. Due to the non-continuity of similarity of the inlet crude coal tar feed, the quinolone and toluene insolubility parameters and cocking value measurements were suggested as effective experimental methods to mitigate the effect of this non-similarity and reduced the risk of the flooding phenomena on vacuum distillation trays column. Pilot processing is useful to adjust the laboratory obtained results and their relations with semi-industrial attempts and is recommended for future directions for the research.