Skip to main content
Log in

Pressure monitoring based identification of the EOD suit–human interface load distribution

  • Regular Paper
  • Published:
International Journal of Intelligent Robotics and Applications Aims and scope Submit manuscript

Abstract

Soldiers working in the field of explosive ordnance disposal (EOD) wear cumbersome personal protective equipment (PPE) that may affect their performance in the field, limit their mobility, and cause discomfort. The objective of this study was to develop a test methodology to identify the relationship between EOD suit interface loads and mission-critical performance metrics. The physical interactions between an EOD suit and human subjects were monitored using a distributed pressure sensor network to investigate the interface load distribution during EOD-related physical positions and activities. More specifically, a Med-Eng brand Model EOD 8 suit was utilized to evaluate shoulder discomfort and leg mobility restriction. Thirty-four college aged adults of varying athletic abilities completed a test course and walked on a treadmill for 2 min while wearing the EOD 8. Demographic information was collected before testing via a survey and qualitative observations were collected at the end of testing with a questionnaire. After each test course repetition, participants ranked their perceived exertion using the Borg scale. Overall, the time it took participants to complete the test course increased by 17% and participants experienced a 60% increase in perceived exertion while wearing the EOD 8. The region that experienced the most pain and discomfort was the top of the shoulders (59%) and there was a negative correlation (r = − 0.5, p < 0.05) between participants’ body mass index (BMI) and the max shoulder pressure. The groin protector was found to restrict hip rotation when the subject squatted to pick up an object, producing a pressure 30-times higher than without the EOD 8. These results suggest that a range of motion evaluation method for EOD suits and other protective ensemble can be successfully developed using a combination of user feedback and strategically placed pressure sensors. This study implements the largest pressure region ever recorded on the human body and is the first of its kind to investigate the movement restriction of PPE for various practical tasks.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13

Similar content being viewed by others

References

Download references

Acknowledgements

This project is sponsored by the Department of the Army, U.S. Army CCDC Soldier Center. Distribution Statement: Approved for public release; distribution is unlimited (PAO #: U20-2265). Thank you to the NERVE Center and SDASL at UMass Lowell for providing the test course, research assistance, and for cleaning the suits. We would like to also thank Marina Carboni from the U.S. Army CCDC SC, Jaclyn Solimine and Pablo Ruiz for their help with the implementation of the pressure sensors and data processing.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Murat Inalpolat.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Deane, N., Gu, Y., Kao, PC. et al. Pressure monitoring based identification of the EOD suit–human interface load distribution. Int J Intell Robot Appl 5, 410–423 (2021). https://doi.org/10.1007/s41315-021-00178-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s41315-021-00178-z

Keywords

Navigation