Skip to main content
Log in

State of art review on PP-band retrofitting for masonry structures

  • Review
  • Published:
Innovative Infrastructure Solutions Aims and scope Submit manuscript

Abstract

Experience from earthquakes has shown that the collapse of unreinforced masonry structures causes a larger number of loss of life during these events in developing countries. Therefore, there is an urgent need to improve their seismic performance to reduce future fatalities and to protect the existing housing stock. To effectively promote seismic retrofitting, inexpensive and simple technical solutions are required. Because in many regions self-construction is predominant, it is expected that any retrofitting initiative will also be taken by the house resident. Consequently, it is also important that the retrofitting procedure does not require highly skilled labor. Polypropylene band (PP-band) retrofitting method satisfies these two key requirements. PP-bands are commonly used for packing, which is inexpensive, worldwide available and durable. This paper focuses on reviewing the PP-band seismic retrofitting considering tests conducted to evaluate the efficiency of the retrofitting method, factors affecting the retrofitting, promotion technique, limitation and feature research focus of the PP-band retrofitting method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13

Similar content being viewed by others

References

  1. Rajendra D, Rupal D, Pawan J, Mukerji RK, Harshad T (2013) Technical guideline and information for stone construction in Uttarakhand. Disaster Mitigation and Management Centre, Uttarakhand

    Google Scholar 

  2. Amiraslanzadeh R, Ikemoto T, Miyajima M, Fallahi A (2012) A comparative study on seismic retrofitting methods for unreinforced masonry brick walls. In: 15th World conference on earthquake engineering, Lisbon, Portugal

  3. Varum H, Tarque N, Silveira D, Camata G, Lobo B, Blondet B, Figueiredo A, Rafi MM, Oliveira C, Costa A (2014) Structural behaviour and retrofitting of adobe masonry buildings. In: Costa A, Guedes JM, Varum H (eds) Structural rehabilitation of old buildings, building pathology and rehabilitation 2. Springer, Berlin

    Google Scholar 

  4. Helifix (2014) Crack stitching: a reliable and cost-effective means of repairing and stabilizing cracked masonry. Product sheet—PS/CS01, Helifix sustainable structural solution, Australia

  5. Blondet M, Aguilar R (2007) Seismic protection of earthen buildings. In: International symposium on Earthen structures. Indian Institute of Science, Bangalore, India

  6. Sathiparan N, Mayorca P, Meguro K (2012) Shake table tests on one-quarter scale models of masonry houses retrofitted with PP-band mesh. Earthq Spectra 28(1):277–299

    Article  Google Scholar 

  7. Shrestha HD, Subedi J, Rajbhandari M (2016) Seismic retrofitting guidelines of buildings in Nepal. Centre of Resilient Development (CoRD) and MRB Associates, Department of Urban Development and Building Construction, Kathmandu

    Google Scholar 

  8. Tetley R, Madabhushi G (2007) Vulnerability of adobe buildings under earthquake loading. In: 4th conference earthquake geotechnical engineering, Thessaloniki, Greece

  9. Charleson A, Blondet M (2012) Seismic reinforcement for adobe houses with straps from used car tires. Earthq Spectra 28(2):511–530

    Article  Google Scholar 

  10. Bayer AG (2012) A high-tech adhesive and glass fiber fabric are making homes safer: seismic wallpaper. Bayer Sci Mag 23:16–19

    Google Scholar 

  11. Lawrence FK (1984) Shotcrete strengthening of brick masonry walls. Concr Int 6(7):34–40

    Google Scholar 

  12. Torrealva D, José A (2005) Reinforcing adobe buildings with exterior compatible mesh. In: SismoAdobe 2005: architecture, construction and conservation of earthen buildings in seismic areas, Lima. Pontificia Universidad Católica del Perú, Lima, Peru

  13. Dowling D, Samali B and Li J (2005) An improved means of reinforcing adobe walls: external vertical reinforcement. In: SismoAdobe 2005: architecture, construction and conservation of earthen buildings in seismic areas, Lima. Pontificia Universidad Católica del Perú, Lima, Peru

  14. Singhal V, Durgesh CR (2018) Behavior of confined masonry walls with openings under in-plane and out-of-plane loads. Earthq Spectra 34(2):817–841

    Article  Google Scholar 

  15. Ehshani MR, Saadatmanesh H, Velazquez-Dimas JI (1999) Behaviour of retrofitted URM walls under simulated earthquake loading. J Compos Constr 3(3):134–142

    Article  Google Scholar 

  16. ElGawady MA, Lestuzzi P, Badoux M (2006) A seismic retrofitting of unreinforced masonry walls using FRP. Compos Part B 37:148–162

    Article  Google Scholar 

  17. Bischof P, Suter R (2014) Retrofitting masonry walls with carbon mesh. Polymers 6:280–299

    Article  Google Scholar 

  18. San Bartolome A, Quiun D, Zegarra L (2008). Performance of reinforced adobe houses in Pisco, Peru earthquake. In: 14th World conference on earthquake engineering, Beijing, China

  19. Sathiparan N, Meguro K (2013) Shear and flexural bending strength of masonry wall retrofitted using PP-band mesh. Constructii 14(1):3–12

    Google Scholar 

  20. Sathiparan N, Mayorca P, Nesheli K, Ramesh G, Meguro K (2005) Experimental study on in-plane and out-of-plane behavior of masonry wallettes retrofitted by PP-band meshes. Seisan Kenkyu 57(6):530–533

    Google Scholar 

  21. Mayorca P, Meguro K (2008) A step towards the formulation of a simple method to design pp-band mesh retrofitting for adobe/masonry houses. In: 14th World conference on earthquake engineering, Beijing, China

  22. Mayorca P, Sathiparan N, Guragain R, Meguro K (2006) Comparison of the seismic performance of different strength masonry structures retrofitted with PP-band meshes. In: 5th international symposium on new technologies for urban safety of mega cities in Asia, Nov 2006, Phuket, Thailand

  23. Mayorca P, Meguro K (2004) Proposal of an efficient technique for retrofitting unreinforced masonry dwellings. In: 13th World conference on earthquake engineering, Vancouver, BC, Canada.

  24. Sathiparan N, Nissanka NAAC, Priyankara RLS (2016) A comparative study of mesh type retrofitting for unreinforced masonry under in-plane loading. Arab J Sci Eng 41(4):1391–1401

    Article  Google Scholar 

  25. Heydariha JZ, Ghaednia H, Nayak S, Das S, Bhattacharya S, Dutta SC (2019) Experimental and field performance of PP band–retrofitted masonry: evaluation of seismic behavior. J Perform Constr Fac 33(1):04018086

    Article  Google Scholar 

  26. Sathiparan N, Mayorca P, Nesheli K, Ramesh G, Meguro K (2006) Experimental study on unburned brick masonry wallettes retrofitted by PP-band meshes. Seisan Kenkyu 58(3):301–304

    Google Scholar 

  27. Sathiparan N, Mayorca P, Meguro K (2008) Parametric study on diagonal shear and out-of-plane behavior of masonry wallettes retrofitted by PP-band mesh. In: 14th World conference on earthquake engineering, Beijing, China

  28. Sakurai K, Sathiparan N, Meguro K (2009) Experimental study of masonry wallette made of shapeless stone retrofitted by PP-band mesh. J Jpn Soc Civ Eng (Struct Eng Earthq Eng) 65(1):388–392

    Google Scholar 

  29. Umair SM, Numada M, Amin MN, Meguro K (2015) Fiber reinforced polymer and polypropylene composite retrofitting technique for masonry structures. Polymers 7(5):963–984

    Article  Google Scholar 

  30. Banerjee S, Nayak S, Das S (2020) Improving the in-plane behavior of brick masonry wallet using PP Band and steel wire mesh. J Mater Civ Eng 32(6):04020132

    Article  Google Scholar 

  31. Sathiparan N, Sakurai K, Numada M, Meguro K (2013) Experimental investigation on the seismic performance of PP-band strengthening stone masonry houses. Bull Earthq Eng 11(6):2177–2196

    Article  Google Scholar 

  32. Sathiparan N, Sakurai K, Numada M, Meguro K (2014) Seismic evaluation of earthquake resistance and retrofitting measures for two story masonry houses. Bull Earthq Eng 12(4):1805–1826

    Article  Google Scholar 

  33. Sathiparan N, Meguro K (2012) Seismic behavior of low earthquake resistant arch shaped roof masonry houses retrofitted by PP-band meshes. ASCE J Pract Period Struct Des Constr 17(2):54–64

    Article  Google Scholar 

  34. Sathiparan N, Meguro K (2015) Strengthening of adobe houses with arch roofs using tie-bars and polypropylene band mesh. Constr Build Mater 82:360–375

    Article  Google Scholar 

  35. Dar AM, Umair SM, Numada M, Meguro K (2013) Seismic retrofitting of masonry structure with reduced PP-band mesh connectivity. Seisan Kenkyu 65(6):787–793

    Google Scholar 

  36. Umair SM, Numada M, Amin MN, Meguro K (2016) Seismic response of PP-band and FRP retrofitted house models under shake table testing. Constr Build Mater 111:298–316

    Article  Google Scholar 

  37. Nesheli K, Sathiparan N, Ramesh G, Mayorca P, Ito F, Kagawa H, Tsugawa T, Meguro K (2006) Full-scale shaking table tests on masonry buildings retrofitted by PP-band meshes. In: 5th international symposium on new technologies for urban safety of mega cities in Asia, Phuket, Thailand

  38. Mayorca P, Meguro K (2003) Modeling masonry structures using the applied element method. Seisan Kenkyu 55(6):581–584

    Google Scholar 

  39. Guragain R, Worakanchana K, Mayorca P, Meguro K (2007) Simulation of brick masonry wall behavior under cyclic loading using applied element method. Bull Earthq Resist Struct Res Cent 40:43–52

    Google Scholar 

  40. Worakanchana K, Mayorca P, Guragain R, Sathiparan N, Meguro K (2008) 3-D applied element method for PP-band retrofitted masonry. In: 14th World conference on earthquake engineering, Beijing, China

  41. Sathiparan N (2018) Effect of roof and diaphragm connectivity on dynamic behaviour of the PP-band retrofitted adobe masonry structures. Period Polytech Civ Eng 62(4):992–1000

    Google Scholar 

  42. Meguro K (2007) International cooperation and earthquake disaster reduction—implementation of earthquake safer housing through technological and social approaches. In: 2nd international conference on urban disaster reduction, Taipei, Taiwan

  43. Japan Bank for International Cooperation (JBIC), International Center for Urban Safety Engineering, & OYO International Corporation (2007) Pilot studies for knowledge assistance for verification and promotion on a new seismic retrofitting method for existing masonry houses by polypropylene band mesh (The Islamic Republic of IRAN), Tokyo, Japan

  44. Meguro K (2010) Towards earthquake safer non-engineering houses by technological and social approaches. In: 7th international conference on urban earthquake engineering (7CUEE) and 5th international conference on earthquake engineering, Tokyo, Japan

  45. Numada M, Watanabe M, Kuroda M, Meguro K (2013) Application of PP-band mesh technology to retrofit the masonry structure—case study of the building of orphanage in Indonesia. Seisan Kenkyu 65(4):441–446

    Google Scholar 

  46. Iritani S, Mayorca P, Meguro K (2007) Proposal of a system to promote retrofitting of vulnerable masonry houses in developing countries. Bull Earthq Resist Struct Res Cent 41:1–6

    Google Scholar 

  47. Sathiparan N (2015) Mesh type seismic retrofitting for masonry structures: critical issues and possible strategies. Eur J Environ Civ Eng 19(9):1136–1154

    Article  Google Scholar 

  48. Mayorca P, Sathiparan N, Meguro K (2006) Report on the state of the art in the seismic retrofitting of unreinforced masonry houses by PP meshes. International Centre for Urban Safety Engineering, Institute of Industrial Science, University of Tokyo, Tokyo

    Google Scholar 

Download references

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Navaratnarajah Sathiparan.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sathiparan, N. State of art review on PP-band retrofitting for masonry structures. Innov. Infrastruct. Solut. 5, 62 (2020). https://doi.org/10.1007/s41062-020-00316-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s41062-020-00316-9

Keywords

Navigation