Abstract
Experience from earthquakes has shown that the collapse of unreinforced masonry structures causes a larger number of loss of life during these events in developing countries. Therefore, there is an urgent need to improve their seismic performance to reduce future fatalities and to protect the existing housing stock. To effectively promote seismic retrofitting, inexpensive and simple technical solutions are required. Because in many regions self-construction is predominant, it is expected that any retrofitting initiative will also be taken by the house resident. Consequently, it is also important that the retrofitting procedure does not require highly skilled labor. Polypropylene band (PP-band) retrofitting method satisfies these two key requirements. PP-bands are commonly used for packing, which is inexpensive, worldwide available and durable. This paper focuses on reviewing the PP-band seismic retrofitting considering tests conducted to evaluate the efficiency of the retrofitting method, factors affecting the retrofitting, promotion technique, limitation and feature research focus of the PP-band retrofitting method.
Similar content being viewed by others
References
Rajendra D, Rupal D, Pawan J, Mukerji RK, Harshad T (2013) Technical guideline and information for stone construction in Uttarakhand. Disaster Mitigation and Management Centre, Uttarakhand
Amiraslanzadeh R, Ikemoto T, Miyajima M, Fallahi A (2012) A comparative study on seismic retrofitting methods for unreinforced masonry brick walls. In: 15th World conference on earthquake engineering, Lisbon, Portugal
Varum H, Tarque N, Silveira D, Camata G, Lobo B, Blondet B, Figueiredo A, Rafi MM, Oliveira C, Costa A (2014) Structural behaviour and retrofitting of adobe masonry buildings. In: Costa A, Guedes JM, Varum H (eds) Structural rehabilitation of old buildings, building pathology and rehabilitation 2. Springer, Berlin
Helifix (2014) Crack stitching: a reliable and cost-effective means of repairing and stabilizing cracked masonry. Product sheet—PS/CS01, Helifix sustainable structural solution, Australia
Blondet M, Aguilar R (2007) Seismic protection of earthen buildings. In: International symposium on Earthen structures. Indian Institute of Science, Bangalore, India
Sathiparan N, Mayorca P, Meguro K (2012) Shake table tests on one-quarter scale models of masonry houses retrofitted with PP-band mesh. Earthq Spectra 28(1):277–299
Shrestha HD, Subedi J, Rajbhandari M (2016) Seismic retrofitting guidelines of buildings in Nepal. Centre of Resilient Development (CoRD) and MRB Associates, Department of Urban Development and Building Construction, Kathmandu
Tetley R, Madabhushi G (2007) Vulnerability of adobe buildings under earthquake loading. In: 4th conference earthquake geotechnical engineering, Thessaloniki, Greece
Charleson A, Blondet M (2012) Seismic reinforcement for adobe houses with straps from used car tires. Earthq Spectra 28(2):511–530
Bayer AG (2012) A high-tech adhesive and glass fiber fabric are making homes safer: seismic wallpaper. Bayer Sci Mag 23:16–19
Lawrence FK (1984) Shotcrete strengthening of brick masonry walls. Concr Int 6(7):34–40
Torrealva D, José A (2005) Reinforcing adobe buildings with exterior compatible mesh. In: SismoAdobe 2005: architecture, construction and conservation of earthen buildings in seismic areas, Lima. Pontificia Universidad Católica del Perú, Lima, Peru
Dowling D, Samali B and Li J (2005) An improved means of reinforcing adobe walls: external vertical reinforcement. In: SismoAdobe 2005: architecture, construction and conservation of earthen buildings in seismic areas, Lima. Pontificia Universidad Católica del Perú, Lima, Peru
Singhal V, Durgesh CR (2018) Behavior of confined masonry walls with openings under in-plane and out-of-plane loads. Earthq Spectra 34(2):817–841
Ehshani MR, Saadatmanesh H, Velazquez-Dimas JI (1999) Behaviour of retrofitted URM walls under simulated earthquake loading. J Compos Constr 3(3):134–142
ElGawady MA, Lestuzzi P, Badoux M (2006) A seismic retrofitting of unreinforced masonry walls using FRP. Compos Part B 37:148–162
Bischof P, Suter R (2014) Retrofitting masonry walls with carbon mesh. Polymers 6:280–299
San Bartolome A, Quiun D, Zegarra L (2008). Performance of reinforced adobe houses in Pisco, Peru earthquake. In: 14th World conference on earthquake engineering, Beijing, China
Sathiparan N, Meguro K (2013) Shear and flexural bending strength of masonry wall retrofitted using PP-band mesh. Constructii 14(1):3–12
Sathiparan N, Mayorca P, Nesheli K, Ramesh G, Meguro K (2005) Experimental study on in-plane and out-of-plane behavior of masonry wallettes retrofitted by PP-band meshes. Seisan Kenkyu 57(6):530–533
Mayorca P, Meguro K (2008) A step towards the formulation of a simple method to design pp-band mesh retrofitting for adobe/masonry houses. In: 14th World conference on earthquake engineering, Beijing, China
Mayorca P, Sathiparan N, Guragain R, Meguro K (2006) Comparison of the seismic performance of different strength masonry structures retrofitted with PP-band meshes. In: 5th international symposium on new technologies for urban safety of mega cities in Asia, Nov 2006, Phuket, Thailand
Mayorca P, Meguro K (2004) Proposal of an efficient technique for retrofitting unreinforced masonry dwellings. In: 13th World conference on earthquake engineering, Vancouver, BC, Canada.
Sathiparan N, Nissanka NAAC, Priyankara RLS (2016) A comparative study of mesh type retrofitting for unreinforced masonry under in-plane loading. Arab J Sci Eng 41(4):1391–1401
Heydariha JZ, Ghaednia H, Nayak S, Das S, Bhattacharya S, Dutta SC (2019) Experimental and field performance of PP band–retrofitted masonry: evaluation of seismic behavior. J Perform Constr Fac 33(1):04018086
Sathiparan N, Mayorca P, Nesheli K, Ramesh G, Meguro K (2006) Experimental study on unburned brick masonry wallettes retrofitted by PP-band meshes. Seisan Kenkyu 58(3):301–304
Sathiparan N, Mayorca P, Meguro K (2008) Parametric study on diagonal shear and out-of-plane behavior of masonry wallettes retrofitted by PP-band mesh. In: 14th World conference on earthquake engineering, Beijing, China
Sakurai K, Sathiparan N, Meguro K (2009) Experimental study of masonry wallette made of shapeless stone retrofitted by PP-band mesh. J Jpn Soc Civ Eng (Struct Eng Earthq Eng) 65(1):388–392
Umair SM, Numada M, Amin MN, Meguro K (2015) Fiber reinforced polymer and polypropylene composite retrofitting technique for masonry structures. Polymers 7(5):963–984
Banerjee S, Nayak S, Das S (2020) Improving the in-plane behavior of brick masonry wallet using PP Band and steel wire mesh. J Mater Civ Eng 32(6):04020132
Sathiparan N, Sakurai K, Numada M, Meguro K (2013) Experimental investigation on the seismic performance of PP-band strengthening stone masonry houses. Bull Earthq Eng 11(6):2177–2196
Sathiparan N, Sakurai K, Numada M, Meguro K (2014) Seismic evaluation of earthquake resistance and retrofitting measures for two story masonry houses. Bull Earthq Eng 12(4):1805–1826
Sathiparan N, Meguro K (2012) Seismic behavior of low earthquake resistant arch shaped roof masonry houses retrofitted by PP-band meshes. ASCE J Pract Period Struct Des Constr 17(2):54–64
Sathiparan N, Meguro K (2015) Strengthening of adobe houses with arch roofs using tie-bars and polypropylene band mesh. Constr Build Mater 82:360–375
Dar AM, Umair SM, Numada M, Meguro K (2013) Seismic retrofitting of masonry structure with reduced PP-band mesh connectivity. Seisan Kenkyu 65(6):787–793
Umair SM, Numada M, Amin MN, Meguro K (2016) Seismic response of PP-band and FRP retrofitted house models under shake table testing. Constr Build Mater 111:298–316
Nesheli K, Sathiparan N, Ramesh G, Mayorca P, Ito F, Kagawa H, Tsugawa T, Meguro K (2006) Full-scale shaking table tests on masonry buildings retrofitted by PP-band meshes. In: 5th international symposium on new technologies for urban safety of mega cities in Asia, Phuket, Thailand
Mayorca P, Meguro K (2003) Modeling masonry structures using the applied element method. Seisan Kenkyu 55(6):581–584
Guragain R, Worakanchana K, Mayorca P, Meguro K (2007) Simulation of brick masonry wall behavior under cyclic loading using applied element method. Bull Earthq Resist Struct Res Cent 40:43–52
Worakanchana K, Mayorca P, Guragain R, Sathiparan N, Meguro K (2008) 3-D applied element method for PP-band retrofitted masonry. In: 14th World conference on earthquake engineering, Beijing, China
Sathiparan N (2018) Effect of roof and diaphragm connectivity on dynamic behaviour of the PP-band retrofitted adobe masonry structures. Period Polytech Civ Eng 62(4):992–1000
Meguro K (2007) International cooperation and earthquake disaster reduction—implementation of earthquake safer housing through technological and social approaches. In: 2nd international conference on urban disaster reduction, Taipei, Taiwan
Japan Bank for International Cooperation (JBIC), International Center for Urban Safety Engineering, & OYO International Corporation (2007) Pilot studies for knowledge assistance for verification and promotion on a new seismic retrofitting method for existing masonry houses by polypropylene band mesh (The Islamic Republic of IRAN), Tokyo, Japan
Meguro K (2010) Towards earthquake safer non-engineering houses by technological and social approaches. In: 7th international conference on urban earthquake engineering (7CUEE) and 5th international conference on earthquake engineering, Tokyo, Japan
Numada M, Watanabe M, Kuroda M, Meguro K (2013) Application of PP-band mesh technology to retrofit the masonry structure—case study of the building of orphanage in Indonesia. Seisan Kenkyu 65(4):441–446
Iritani S, Mayorca P, Meguro K (2007) Proposal of a system to promote retrofitting of vulnerable masonry houses in developing countries. Bull Earthq Resist Struct Res Cent 41:1–6
Sathiparan N (2015) Mesh type seismic retrofitting for masonry structures: critical issues and possible strategies. Eur J Environ Civ Eng 19(9):1136–1154
Mayorca P, Sathiparan N, Meguro K (2006) Report on the state of the art in the seismic retrofitting of unreinforced masonry houses by PP meshes. International Centre for Urban Safety Engineering, Institute of Industrial Science, University of Tokyo, Tokyo
Funding
Not applicable.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Sathiparan, N. State of art review on PP-band retrofitting for masonry structures. Innov. Infrastruct. Solut. 5, 62 (2020). https://doi.org/10.1007/s41062-020-00316-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s41062-020-00316-9