Abstract
Frequency response analysis (FRA) is the widely used condition monitoring technique for the power transformer. Test instruments performing FRA test can broadly be categorised as high-end equipment (HE) and laboratory equipment (LE), respectively. The accuracy of the generated data depends on the HE and LE to a greater extent. The proposed work includes absolute study of such test instrument in order to understand repeatability in FRA measurements. Moreover, natural frequencies and amplitudes are identified from the FRA plots in order to perform sensitivity analysis. This paper proposes, two non-parametric, statistical methods, namely the Mann–Whitney U-test and quantile–quantile plot for the comparison of the amplitude data. To validate the findings, experiments are performed on the model coil, the disc winding and the three-phase transformer.
Similar content being viewed by others
References
Abu-Siada A, Aljohani O (2018) Detecting incipient radial deformations of power transformer windings using polar plot and digital image processing. IET Sci Measure Technol 12(4):492–499. https://doi.org/10.1049/iet-smt.2017.0412
Amara A, Gacemi A, Houassine H et al (2021) A novel methodology for high-frequency lumped equivalent circuit of an isolated transformer winding construction based on frequency response analysis signal morphology interpretation. IET Electric Power Appl 15(2):171–185. https://doi.org/10.1049/elp2.12013
Arumugam S (2014) Experimental investigation on terminal connection and system function pair during sfra testing on three phase transformers. Int J Electrical Power Energy Syst 58:101–110. https://doi.org/10.1016/j.ijepes.2014.01.003
Badgujar K, Maoyafikuddin M, Kulkarni S (2012) Alternative statistical techniques for aiding SFRA diagnostics in transformers. IET Generation Trans Distrib 6(3):189–198. https://doi.org/10.1049/iet-gtd.2011.0268
Behjat V, Mahvi M (2015) Statistical approach for interpretation of power transformers frequency response analysis results. IET Sci Measure Technol 9(3):367–375. https://doi.org/10.1049/iet-smt.2014.0097
Behjat V, Mahvi M, Rahimpour E (2016) New statistical approach to interpret power transformer frequency response analysis: non-parametric statistical methods. IET Sci Measure Technol 10(4):364–369. https://doi.org/10.1049/IET-SMT.2015.0204
Bigdeli M, Abu-Siada A (2022) Clustering of transformer condition using frequency response analysis based on k-means and goa. Electric Power Syst Res 202(107):619. https://doi.org/10.1016/j.epsr.2021.107619
Cheng Y, Bi J, Chang W et al (2020) Proposed methodology for online frequency response analysis based on magnetic coupling to detect winding deformations in transformers. High Voltage 5(3):343–349. https://doi.org/10.1049/hve.2019.0134
CIGRE WG:A2.26 (2008) Mechanical condition assessment of transformer windings using Frequency Response Analysis (FRA)
De Andrade Ferreira RS, Picher P, Ezzaidi H, et al (2021) Frequency response analysis interpretation using numerical indices and machine learning: a case study based on a laboratory model. IEEE Access 9:67051–67063. https://doi.org/10.1109/ACCESS.2021.3076154
Dhar SS, Chakraborty B, Chaudhuri P (2014) Comparison of multivariate distributions using quantile-quantile plots and related tests. Bernoulli 20(3):1484–1506. https://doi.org/10.3150/13-BEJ530
Dick E, Erven C (1978) Transformer diagnostic testing by frequency response analysis. IEEE Trans Power Apparat syst PAS 97(6):2144–2153. https://doi.org/10.1109/TPAS.1978.354718
Doble Engineering (2011) Doble Engineering company Sweep Frequency Response Analyzer-User guide
Guillemin E (1957) Synthesis of passive networks. John Wiley & Sons Inc, New York
IEC 60076-18:2012 (2012) Power transformers—part 18: measurement of frequency response
IEEE C57.149:2012 (2012) IEEE guide for the application and interpretation of frequency response analysis for oil-immersed transformers
Islam MM, Lee G, Hettiwatte SN (2018) A review of condition monitoring techniques and diagnostic tests for lifetime estimation of power transformers. Electrical Eng 100(2):581–605. https://doi.org/10.1007/s00202-017-0532-4
Kim JW, Park B, Jeong SC et al (2005) Fault diagnosis of a power transformer using an improved frequency-response analysis. IEEE Trans Power Delivery 20(1):169–178. https://doi.org/10.1109/TPWRD.2004.835428
Krupa S, Ragavan K (2014) Locating mechanical deformations in electromagnetic model of transformer winding. In: 2014 Eighteenth national power systems conference (NPSC), IEEE, pp 1–6
Kulkarni SV, Khaparde SA (2017) Transformer engineering: design, technology, and diagnostics. CRC Press, Boca Raton
Mayora H, Alvarez R, Bossio G, et al (2022) Experiences of fra measurements on medium voltage rotating machines. In: 2022 IEEE electrical insulation conference (EIC), IEEE, pp 253–256, https://doi.org/10.1109/EIC51169.2022.9833183
Montgomery DC, Runger GC (2010) Applied statistics and probability for engineers. John Wiley & Sons, Hoboken
Nirgude PM, Ashokraju D, Rajkumar A et al (2008) Application of numerical evaluation techniques for interpreting frequency response measurements in power transformers. IET Sci Measure Technol 2(5):275–285. https://doi.org/10.1049/iet-smt:20070072
Ryder SA (2002) Methods for comparing frequency response analysis measurements. In: Conference record of the the 2002 IEEE international symposium on electrical insulation (Cat. No. 02CH37316). p 187–190, https://doi.org/10.1109/ELINSL.2002.995909
Satish L, Saravanakumar A (2008) Identification of terminal connection and system function for sensitive frequency response measurement on transformers. IEEE Trans Power Delivery 23(2):742–750. https://doi.org/10.1109/TPWRD.2008.915808
Secue J, Mombello E (2008) Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in power transformers. Electric Power Syst Res 78(6):1119–1128. https://doi.org/10.1016/j.epsr.2007.08.005
Song KS (2013) Asymptotic relative efficiency and exact variance stabilizing transformation for the generalized gaussian distribution. IEEE Trans Inf Theory 59(7):4389–4396. https://doi.org/10.1109/TIT.2013.2249182
Tahir M, Tenbholen S, Miyazaki S (2021) Analysis of statistical methods for assessment of power transformer frequency response measurements. IEEE Trans Power Delivery 36(2):618–626. https://doi.org/10.1109/TPWRD.2020.2987205
Tsai DM, Yang CH (2005) A quantile-quantile plot based pattern matching for defect detection. Pattern Recogn Lett 26(13):1948–1962. https://doi.org/10.1016/j.patrec.2005.02.002
Waters M (1966) The short-circuit strength of power transformers. Macdonald & Company
Wayne Kerr Electronics (2003) Wayne Kerr 3260 series sweep frequency response analyzer-user manual
Acknowledgements
The authors would like to thank faculty members and laboratory technicians at Indian Institute of Technology Gandhinagar and Ms. Setu Vora, Deputy General Manager, Atlanta Electricals Pvt. Ltd., Anand for giving permission to access mentioned case studies.
Funding
No funding was received for conducting this study, and the authors have no relevant financial or non-financial interests to disclose.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Reddy, R., Shah, K. & Kallamadi, M. Performance Evaluation of Laboratory and Industrial Equipment in FRA Measurement. Iran J Sci Technol Trans Electr Eng 48, 187–199 (2024). https://doi.org/10.1007/s40998-023-00650-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40998-023-00650-5