Abstract
The safety level of curtain wall panel will gradually decrease with the increase in service time due to the aging of materials, corrosion and looseness of fasteners. Therefore, the deformation monitoring analysis of building curtain wall based on optical fiber sensing technology was proposed. In this paper, the relationship between the stable state of the curtain wall panel and its dynamic characteristic parameters was studied. For this purpose, the optical fiber sensing technology into the deformation monitoring of the curtain wall was introduced, and the optical fiber sensing model of the stability of the glass curtain wall with the input layer content and hidden layer content was established. Moreover, the remote, rapid and accurate quantitative evaluation of the safety state of the curtain wall panel was realized to complete the deformation monitoring analysis of the curtain wall. The experimental results showed that the optical fiber sensing model can effectively monitor the stability of glass curtain wall, and the monitoring effect of building curtain wall using optical fiber sensing technology was better.
Similar content being viewed by others
References
Agustín TR, David MG, Daniel AÁ (2020) Thermal performance evaluation of a passive building wall with CO 2-filled transparent thermal insulation and paraffin-based PCM. Sol Energy 205(5):1–11
Bari AA, Martín-Garín JA (2020) Porous media to intensify natural convection in rectangular enclosures used in building techniques. Int J Mod Phys C (IJMPC) 31(12):59–62
Bedeir H, Shedid M, Okail H, Hamdy O (2019) Numerical modeling of a two story third-scale reinforced masonry shear wall building subjected to quasi-static lateral loading. Eng Struct 181(15):310–323
Elveny M, Alrazzak NA, Aljeboree AM, Alkaim AF, Ebadi A (2021) Substituent effects of fused Hammick germylenes: estimating the stability and reactivity using density functional theory. J Phys Org Chem 12:e4262. https://doi.org/10.1002/poc.4262
Huang J, Sun Y, Zhang J (2021a) Reduction of computational error by optimizing SVR kernel coefficients to simulate concrete compressive strength through the use of a human learning optimization algorithm. Eng Comput. https://doi.org/10.1007/s00366-021-01305-x
Huang J, Zhang Y, Sun Y, Ren J, Zhao Z, Zhang J (2021b) Evaluation of pore size distribution and permeability reduction behavior in pervious concrete. Constr Build Mater 290:123228. https://doi.org/10.1016/j.conbuildmat.2021.123228
Jorge AV, Rosita J, Llera JCDL, Hube MA, Chacón MF (2020) Three-dimensional nonlinear response history analyses for earthquake damage assessment: a reinforced concrete wall building case study. Earthq Spectra 87(5):15–21
Kolozvari K, Terzic V, Miller R, Saldana D (2018) Assessment of dynamic behavior and seismic performance of a high-rise recoupled wall building. Eng Struct 176(1):606–620
Lalas P (2019) Retaining the existing 57-year-old curtainwall on Transpower House, Wellington. Aust J Struct Eng 25(7):1–9
Lee YS, Kim SH, Gil MS, Lee SH, Kang MS, Jang SH (2018) The study on the integrated control system for curtain wall building fade cleaning robot. Autom Constr 94(10):39–46
Liu B, Yang H, Karekal S (2020) Effect of water content on argillization of mudstone during the tunnelling process. Rock Mech Rock Eng 53(2):799–813. https://doi.org/10.1007/s00603-019-01947-w
Liu H, Shi Z, Li J, Liu C, Meng X, Du Y, Chen J (2021) Detection of road cavities in urban cities by 3D ground-penetrating radar. Geophysics 86(3):25–33. https://doi.org/10.1190/geo2020-0384.1
Ma A, Ji J, Khayatnezhad M (2021) Risk-constrained non-probabilistic scheduling of coordinated power-to-gas conversion facility and natural gas storage in power and gas based energy systems. Sustain Energy Grids Netw 26:100478
Mnich E, Bjarnholt N, Eudes A, Harholt J, Ulvskov P (2020) Phenolic cross-links: building and de-constructing the plant cell wall. Nat Prod Rep 37(4):25–31
Moon WC, Lau TL, Puay HT (2020) Experimental investigations of tsunami loading on internal wall of a building with various openings and wall configurations. Coast Eng 158(6):103–110
Nejad RM, Liu Z, Ma W, Berto F (2021a) Fatigue reliability assessment of a pearlitic Grade 900A rail steel subjected to multiple cracks. Eng Fail Anal. https://doi.org/10.1016/j.engfailanal.2021.105625
Nejad RM, Liu Z, Ma W, Berto F (2021b) Reliability analysis of fatigue crack growth for rail steel under variable amplitude service loading conditions and wear. Int J Fatigue. https://doi.org/10.1016/j.ijfatigue.2021.106450
Nguyen TT (2018) Seismic assessment of a three-story wood building with an integrated CLT-lightframe system using RTHS. Eng Struct 15(6):159–165
Park HS, Won JH, Chung WJ (2018) Wind resistance performance evaluation of cable-type curtain wall system on reinforced concrete high-rise buildings. Int J Concr Struct Mater 12(1):25
Salar Rahimi M, Vandenbosch GAE (2019) Beam steerable subarray with small footprint for use as building block in wall-mounted indoor wireless infrastructure. IET Microw Antennas Propag 13(4):526–531
Sun L, Li C, Zhang C, Su Z, Chen C (2018) Early monitoring of rebar corrosion evolution based on FBG sensor. Int J Struct Stab Dyn 18(08):1840001–1842018. https://doi.org/10.1142/S0219455418400011
Sun L, Li C, Zhang C, Liang T, Zhao Z (2019) The strain transfer mechanism of fiber bragg grating sensor for extra large strain monitoring. Sensors (basel, Switzerland) 19(8):1851. https://doi.org/10.3390/s19081851
Sun Q, Lin D, Khayatnezhad M, Taghavi M (2021) Investigation of phosphoric acid fuel cell, linear Fresnel solar reflector and Organic Rankine Cycle polygeneration energy system in different climatic conditions. Process Saf Environ Prot 147:993–1008
Tao Z, Cui Z, Yu J, Khayatnezhad M (2021) Finite difference modeling of groundwater flow for constructing artificial recharge structures. Iran J Sci Technol Trans Civil Eng. https://doi.org/10.1007/s40996-021-00698-5
Wang P, Wang L, Leung H, Zhang G (2021) Super-resolution mapping based on spatial-spectral correlation for spectral imagery. IEEE Trans Geosci Remote Sens 59(3):2256–2268. https://doi.org/10.1109/TGRS.200.3004353
Xu YP, Ouyang P, Xing SM, Qi LY, Khayatnezhad M, Jafari H (2021) Optimal structure design of a PV/FC HRES using amended Water Strider Algorithm. Energy Rep 7:2057–2067
Xuan Q, Li G, Lu Y (2019) Design, optimization and performance analysis of an asymmetric concentrator-PV type window for the building south wall application. Sol Energy 193(12):422–433
Yang HQ, Zeng YY, Lan YF, Zhou XP (2014) Analysis of the excavation damaged zone around a tunnel accounting for geostress and unloading. Int J Rock Mech Min Sci 69:59–66. https://doi.org/10.1016/j.ijrmms.2014.03.003
Yang HQ, Li Z, Jie TQ, Zhang ZQ (2018a) Effects of joints on the cutting behavior of disc cutter running on the jointed rock mass. Tunn Undergr Space Technol 81:112–120. https://doi.org/10.1016/j.tust.2018.07.023
Yang HQ, Xing SG, Wang Q, Li Z (2018b) Model test on the entrainment phenomenon and energy conversion mechanism of flow-like landslides. Eng Geol 239:119–125. https://doi.org/10.1016/j.enggeo.2018.03.023
Yang H, Wang Z, Song K (2020) A new hybrid grey wolf optimizer-feature weighted-multiple kernel-support vector regression technique to predict TBM performance. Eng Comput. https://doi.org/10.1007/s00366-020-01217-2
Zhang C, Alam Z, Sun L, Su Z, Samali B (2019) Fiber Bragg grating sensor-based damage response monitoring of an asymmetric reinforced concrete shear wall structure subjected to progressive seismic loads. Struct Control Health Monit 26(3):e2307. https://doi.org/10.1002/stc.2307
Zhang J, Wang M, Tang Y, Ding Q, Wanga C, Huang X, Yan F (2021) Angular velocity measurement with improved scale factor based on a wideband-tunable optoelectronic oscillator. IEEE Trans Instrum Meas. https://doi.org/10.1109/TIM.2021.3067183
Zhao X, Gu B, Gao F, Chen S (2020) Matching model of energy supply and demand of the integrated energy system in coastal areas. J Coast Res 103(sp1):983. https://doi.org/10.2112/SI103-205.1
Zhao C, Liu X, Zhong S, Shi K, Liao D, Zhong Q (2021) Secure consensus of multi-agent systems with redundant signal and communication interference via distributed dynamic event-triggered control. ISA Trans 112:89–98. https://doi.org/10.1016/j.isatra.2020.11.030
Zhou J, Shen X, Qiu Y, Li E, Rao D, Shi X (2021a) Improving the efficiency of microseismic source locating using a heuristic algorithm-based virtual field optimization method. Geomech Geophys Geo-Energy Geo-Resour. https://doi.org/10.1007/s40948-021-00285-y
Zhou J, Qiu Y, Khandelwal M, Zhu S, Zhang X (2021b) Developing a hybrid model of Jaya algorithm-based extreme gradient boosting machine to estimate blast-induced ground vibrations. Int J Rock Mech Min Sci 145:104856. https://doi.org/10.1016/j.ijrmms.2021.104856
Zhu P, Saadati H, Khayatnezhad M (2021) Application of probability decision system and particle swarm optimization for improving soil moisture content. Water Supply. https://doi.org/10.2166/ws.2021.169
Zorana P, Radovan G, Goran T (2018) Estimation of thermal impulse response of a multi-layer building wall through in-situ experimental measurements in a dynamic regime with applications. Appl Energy 228(12):468–486
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Xu, D., Wang, Y. & Xie, J. Monitoring and Analysis of Building Curtain Wall Deformation Based on Optical Fiber Sensing Technology. Iran J Sci Technol Trans Civ Eng 46, 3081–3091 (2022). https://doi.org/10.1007/s40996-021-00735-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40996-021-00735-3