Skip to main content
Log in

Reliability of a special device for measuring the cross-sectional area of the patellar tendon by ultrasonography

  • Original Paper
  • Published:
Journal of Ultrasound Aims and scope Submit manuscript

Abstract

The objective of this study was to evaluate the intra- and inter-rater reliability and agreement between conditions with and without a special device (SD) in the evaluation of the patellar tendon (PT) cross-sectional area (CSA). Forty trained adult volunteers participated in the study. With the knee positioned at 90°, the ultrasound probe was placed in the transverse plane at 25, 50, and 75% of the PT length. Two raters and one analyzer obtained the images. We use a two-way ANOVA with a significance level of α = 0.05. No significant differences were found between raters or conditions. Intra-rater reliability ranged from moderate to good. Inter-rater reliability without the SD ranged from low to good, improving from moderate to good when the SD was used. Evaluation of the PT ends showed a lower coefficient of variation with the SD. We observed a moderate correlation at the ends and a strong correlation in the middle between conditions. The mean difference in the three positions is small (~ 0.013 cm2/ ~ 1.7%) with an upper limit of 43.2% and a lower limit of 32.5%. Therefore, we conclude that the use of the SD can be employed for evaluating the PT ends, while for the central region, it becomes optional.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

Data availability

The authors confirm that the data supporting the findings of this study are available within the article and its supplementary materials.

References

  1. Ekizos A, Papatzika F, Charcharis G, Bohm S, Mersmann F, Arampatzis A (2013) Ultrasound does not provide reliable results for the measurement of the patellar tendon cross sectional area. J Electromyogr Kinesiol 23(6):1278–1282. https://doi.org/10.1016/j.jelekin.2013.08.004

    Article  PubMed  Google Scholar 

  2. Kongsgaard M, Reitelseder S, Pedersen TG, Holm L, Aagaard P, Kjaer M et al (2007) Region specific patellar tendon hypertrophy in humans following resistance training. Acta Physiol 191(2):111–121. https://doi.org/10.1111/j.1748-1716.2007.01714.x

    Article  CAS  Google Scholar 

  3. Seynnes OR, Erskine RM, Maganaris CN, Longo S, Simoneau EM, Grosset JF et al (2009) Training-induced changes in structural and mechanical properties of the patellar tendon are related to muscle hypertrophy but not to strength gains. J Appl Physiol 107(2):523–530. https://doi.org/10.1152/japplphysiol.00213.2009

    Article  CAS  PubMed  Google Scholar 

  4. Reeves ND, Maganaris CN, Narici MV (2003) Effect of strength training on human patella tendon mechanical properties of older individuals. J Physiol-Lond 548(3):971–981. https://doi.org/10.1113/jphysiol.2002.035576

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  5. Carroll CC, Dickinson JM, Haus JM, Lee GA, Hollon CJ, Aagaard P et al (2008) Influence of aging on the in vivo properties of human patellar tendon. J Appl Physiol 105(6):1907–1915. https://doi.org/10.1152/japplphysiol.00059.2008

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  6. Westh E, Kongsgaard M, Bojsen-Moller J, Aagaard P, Hansen M, Kjaer M et al (2008) Effect of habitual exercise on the structural and mechanical properties of human tendon, in vivo, in men and women. Scand J Med Sci Sports 18(1):23–30. https://doi.org/10.1111/j.1600-0838.2007.00638.x

    Article  CAS  PubMed  Google Scholar 

  7. Gellhorn AC, Carlson MJ (2013) Inter-rater, intra-rater, and inter-machine reliability of quantitative ultrasound measurements of the patellar tendon. Ultrasound Med Biol 39(5):791–796. https://doi.org/10.1016/j.ultrasmedbio.2012.12.001

    Article  PubMed  Google Scholar 

  8. Weinreb JH, Sheth C, Apostolakos J, Mccarthy M, Barden B, Cote MP et al (2014) Tendon structure, disease, and imaging. Muscles Ligaments Tendons J 4(1):66–73

    Article  PubMed  PubMed Central  Google Scholar 

  9. O’connor PJ, Grainger AJ, Morgan SR, Smith KL, Smith KL, Waterton JC, Nash AFP (2004) Ultrasound assessment of tendons in asymptomatic volunteers: a study of reproducibility. Eur Radiol 14(11):1968–1973. https://doi.org/10.1007/s00330-004-2448-4

    Article  PubMed  Google Scholar 

  10. Skou ST, Aalkjaer JM (2013) Ultrasonographic measurement of patellar tendon thickness—a study of intra- and interobserver reliability. Clin Imaging 37(5):934–937. https://doi.org/10.1016/j.clinimag.2013.01.007

    Article  PubMed  Google Scholar 

  11. Castro J, Carvalho KL, Silva PE, Fachin-Martins E, Babault N, Marqueti RC et al (2019) Intra- and inter-rater reproducibility of ultrasound imaging of patellar and quadriceps tendons in critically ill patients. PLoS ONE 14(6):1–15. https://doi.org/10.1371/journal.pone.0219057

    Article  CAS  Google Scholar 

  12. Alves TI, Girish G, Kalume Brigido M, Jacobson JA (2016) US of the knee: scanning techniques, pitfalls, and pathologic conditions. Radiographics 36(6):1759–1775. https://doi.org/10.1148/rg.2016160019

    Article  PubMed  Google Scholar 

  13. Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17(1):101–110. https://doi.org/10.1002/(sici)1097-0258(19980115)17:1%3c101::aid-sim727%3e3.0.co;2-e

    Article  CAS  PubMed  Google Scholar 

  14. VIM (2012) International vocabulary of metrology: basic and general concepts and associated terms, 3rd edn. Joint Committee for Guides in Metrology

    Google Scholar 

  15. Sedrez JA, Candotti CT, Rosa MIZ, Medeiros FS, Marques MT, Los JF (2018) Assessment of Vert-3D repeatability and reproducibility for evaluating the scoliosis of children with different nutritional profiles. Fisioter Mov 30(4):715–723. https://doi.org/10.1590/1980-5918.030.004.AO06

    Article  Google Scholar 

  16. Sarwal A, Parrt SM, Berry MJ, Hsu FC, Lewis MT, Justus NW et al (2015) Interobserver reliability of quantitative muscle sonographic analysis in the critically ill population. J Ultrasound Med 34(7):1191–1200. https://doi.org/10.7863/ultra.34.7.1191

    Article  PubMed  Google Scholar 

  17. Mc Auliffe S, Mc Creesh K, Purtill H, O’sullivan K (2017) A systematic review of the reliability of diagnostic ultrasound imaging in measuring tendon size: is the error clinically acceptable? Phys Therapy Sport 26:52–63. https://doi.org/10.1016/j.ptsp.2016.12.002

    Article  Google Scholar 

  18. Gough JMA, Hamrell M (2010) Standard operating procedures (SOPs): how companies can determine which documents they must put in place. Drug Inf J 44:49–54. https://doi.org/10.1177/009286151004400106

    Article  Google Scholar 

  19. Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometria 33(1):159–174

    Article  CAS  Google Scholar 

  20. Del Baño ME, Martínez-Payá JJ, Ríos-Díaz J, Mejías-Suárez S, Serrano-Carmona S, Groot-Ferrando A (2017) Ultrasound measures of tendon thickness: intra-rater, inter-rater and Inter-machine reliability. Muscles Ligaments Tendons J 7(1):192–199. https://doi.org/10.11138/mltj/2017.7.1.192

    Article  Google Scholar 

Download references

Acknowledgements

This study was financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil (CAPES)-Finance Code 001 and the National Council of Scientific Research (CNPq) Brazil.

Funding

The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the study conception and design. Material preparation, data collection and analysis were performed by ML, RLS, FEF, FCS and LTS. The first draft of the manuscript was written by ML and FEF and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Fernando Diefenthaeler.

Ethics declarations

Conflict of interest

The authors have not disclosed any competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary material 1 (xlsx 19 KB)

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lunardi, M., Furtado, F.E., Sakugawa, R.L. et al. Reliability of a special device for measuring the cross-sectional area of the patellar tendon by ultrasonography. J Ultrasound 26, 897–903 (2023). https://doi.org/10.1007/s40477-023-00829-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40477-023-00829-w

Keywords

Navigation