Evaluation of electric pulp test thresholds and correct probe tip placement site in developing incisors: a clinical study in 1200 teeth

  • Original Scientific Article
  • Published:
European Archives of Paediatric Dentistry Aims and scope Submit manuscript

Abstract

Purpose

Although electric pulp tests (EPT) may play a valuable diagnostic role in traumatized immature permanent teeth, the EPT threshold values which can be used as reference are not known. The aim of this study was to determine the average range of EPT threshold values in healthy permanent incisors according to their stage of root development.

Methods

A total of 1200 permanent incisors were examined in 273 children (142 girls, 131 boys) aged 6–12 years. Panoramic radiographs were used to group teeth according to the stage of root development. A digitest II pulp vitality tester (Parkell, Inc, Edgewood, NY) was used along with toothpaste as the conducting medium to determine sensibility on three different sites (incisal, middle and cervical third).

Results

In all teeth, mean EPT values showed a tendency to decrease along with advanced root development. Irrespective of the stage of root development, the lowest EPT values were obtained when measurements were made on the incisal third of the crown (p < 0.001). Mandibular incisors had lower mean response thresholds than their maxillary counterparts.

Conclusion

The present findings provide reference EPT threshold values according to stage of tooth development to monitor the post traumatic pulp status of permanent incisors.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

Download references

Acknowledgements

This study supported by Development Support Program (PYO.DIS.1904.15.009)of Ondokuz Mayis University, Samsun, Turkey.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. T. Ulusoy.

Ethics declarations

Conflict of interest

The authors have stated explicitly that there is no conflict of interest in connection with this article.

Ethical approval

The ethical approval was received by Commission for Medical Ethics of the Ondokuz Mayıs University.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Turedi, I., Ulusoy, A.T. Evaluation of electric pulp test thresholds and correct probe tip placement site in developing incisors: a clinical study in 1200 teeth. Eur Arch Paediatr Dent 23, 449–454 (2022). https://doi.org/10.1007/s40368-022-00703-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40368-022-00703-z

Keywords

Navigation