Skip to main content

Advertisement

Log in

Design, Development, Analysis and Comparison of Instrumented Irradiation Capsule for Online Determination of Uniaxial Creep Behavior in Structural Specimen Out-of-Pile Test Results with Analytical Results in FBTR

  • Technical Paper
  • Published:
Transactions of the Indian Institute of Metals Aims and scope Submit manuscript

Abstract

The main intent of this work is to develop an instrumented capsule for online determination of uniaxial creep behavior of SS 316L structural specimen. The irradiation capsule has three different zones located one over the other. In the bottom zone of the capsule, the specimen is located, with one end fixed to the bottom portion of capsule and the other end connected to a central tube through a connecting plug. In the top zone a linear variable differential transducer (LVDT) is placed and its core is passed through the central tube. The end point of the LVDT core touches the plug connected to the specimen to measure the elongation of the structural specimen. In this capsule setup, bellows are used to apply a load on the structural specimen with the use of pressurized argon gas. With the application of pressure, the bottom bellow will expand and the top bellow will get compressed. During this expansion of the bottom bellow, tensile load will be applied on the specimen, and the elongation of the structural specimen will be measured by the movement of the core of the LVDT. This paper discusses the details of the design, assembly of an out-of-pile version of instrumented capsule and its experimental results are compared with literature results. The creep experiments have been carried out at three different temperatures and three different stresses (269 MPa at 450 °C, 287 MPa at 500 °C and 306 MPa at 550 °C). Initially the capsule is filled with pre-pressurized argon gas at 6 MPa at room temperature. We have observed that the force/load due to argon gas pressure is the major component for the tensile loading of the specimen and 95% of the total load acts on the SS 316L specimen and remaining 5% load only acts on the bellow. Design concept of instrumented capsule for uniaxial creep measurement has been validated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14

Similar content being viewed by others

References

  1. Schüle W, Hausen H, J Nucl Mater 212215 (1994) 388.

    Article  Google Scholar 

  2. Kim B G, In-situ Creep Testing Capability Development for the Advanced Test Reactor. Idaho National Laboratory, Idaho Falls, ID (2010) INL/EXT-10-17779.

  3. Moilanen P, In-situ Investigation of the Mechanical Performance and Life Time of Copper. Final report on design, construction, and calibration of test module for In-reactor tensile tests in BR2 reactor. VTT Report; BTUO76-031127 (2004).

  4. Singh B N, J Nucl Mater 320 (2003) 299.

    Article  Google Scholar 

  5. Van Nieuwenhove R, Solstad S, in First International Conference on ANIMMA, Marseille, 710 June, 2009.

  6. Solstad S, Van Nieuwenhove R, in Sixth International Topical Meeting on Nuclear Plant Instrumentation, Control and HumanMachine Interface Technologies (NPIC&HMIT), Knoxville, TN, 5–9 April 2009. American Nuclear Society, LaGrange Park, IL.

  7. Wiesenack W, in International Conference on the Physics of Reactors, Nuclear Power: A Sustainable Resource, Casino-Kursaal Conference Center Interlaken, Switzerland, 14–19 Sept 2008.

  8. Karlsen T M, J Nucl Eng Des 207 (2001) 199.

    Article  Google Scholar 

  9. Bennett P, Karlsen T, Energy Mater Mater Sci Eng Energy Syst 3 (2008) 81.

    Article  Google Scholar 

  10. Øwre F, McGrath M, Present Status and Future Plans of the Halden Reactor. Presented at 12th IGORR (Beijing, China, 28–31 Oct. 2009).

  11. Knudson D L, Rempe J L, Daw J E, Evaluation of Candidate Linear Variable Displacement Transducers for High Temperature Irradiations in the Advanced Test Reactor. Idaho National Laboratory, Idaho Falls, ID (2009) INL/EXT-09-16972.

  12. Rehn L, J Nucl Mater 174 (1990) 144.

    Article  Google Scholar 

  13. Hausen H, Schüle W. in Proc 18th Int Symp on Effects of radiation on materials, Hyannis, MA, 25–27 June 1996, , ASTP STP (1996) vol 1325, p 830.

  14. Kim B G. in 1st Int Symp on Materials Testing Reactors JAEA-Oarai, July 2008.

  15. Kim B G, in 6th International Topical Meeting on Nuclear Plant Instrumentation, Control and HumanMachine Interface Technologies (NPIC&HMIT) Knoxville, TN, 59 April. American Nuclear Society, LaGrange Park, IL (2009).

  16. Kim B G, Choo K N, Kim Y K, Ha J J, Cho M S, in 2nd International Symposium on Material Test Reactors Idaho Falls, ID, 28 Sept1 Oct 2009.

  17. Kim B G, Sohn J M, Choo K N Nucl Eng Technol 42 (2010) 203.

    Article  Google Scholar 

  18. Knudson D L, Rempe J L, Meas Sci Technol 23 (2012) 1.

    Article  Google Scholar 

  19. Mohammad K A, Zainudin E S, Salit M S, Zahari N I, and Ali A, Int J Metal Steel Res Technol 1 (2013) 1.

    Google Scholar 

  20. Shetty M N, Dislocations and Mechanical Behavior of Materials, 2nd edn. HI Learning Pvt. Ltd., Delhi (2013).

    Google Scholar 

  21. Dieter GE, Mechanical Metallurgy, 3rd edn. McGraw-Hill Book Co., New York (1988).

    Google Scholar 

  22. Venkatesu S, Saxena R, Chaurasia PK, Muthuganesh M, Murugan M, Venugopal S, Trans Indian Inst Metals 69 (2016) 283.

    Article  Google Scholar 

  23. Standards of the Expansion Joint Manufacturers Association (EJMA), 9th edn. EJMA standards publishers (2008).

Download references

Acknowledgements

The authors thankfully acknowledge the contributions of Shri M. S. Rao and Shri R. Ramesh of IDEAS/MMG in carrying out the preparation of specimens and experimental work.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sadu Venkatesu.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Venkatesu, S., Saxena, R., Murugan, S. et al. Design, Development, Analysis and Comparison of Instrumented Irradiation Capsule for Online Determination of Uniaxial Creep Behavior in Structural Specimen Out-of-Pile Test Results with Analytical Results in FBTR. Trans Indian Inst Met 71, 555–566 (2018). https://doi.org/10.1007/s12666-017-1210-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12666-017-1210-y

Keywords

Navigation