Abstract
Breast cancer is one of the common cancer deaths in women worldwide. Early detection is the key to reduce the mortality rate. Clinical trials have shown that computer aided systems (CAD) have improved the accuracy of breast cancer detection. This paper proposed a highly accurate CAD system based on extracting highly significant features using exact Gaussian–Hermite moments. The obtained feature vector is presented to K-NN, random forests and AdaBoost classifiers. The proposed system is evaluated using two different datasets namely IRMA and MIAS. The evaluation metrics of accuracy, TP, FP and area under ROC curve using 10-fold cross-validation are calculated. The results indicate the usefulness of the proposed exact Gaussian–Hermite moments features for distinguishing between normal and abnormal lesions and the superiority of the moments features compared with the conventional methods.
Similar content being viewed by others
References
Abdelaziz A, Elhoseny M, Salama AS, Riad AM (2018) A machine learning model for improving healthcare services on cloud computing environment. Measurement 119:117–128
Abdelwahed NM, Eltoukhy MM, Wahed ME (2015) Computer aided system for breast cancer diagnosis in ultrasound images. J Ecol Health Environ 3(3):71–76
American Cancer Society (2017) Cancer facts & figures 2017. American Cancer Society, Atlanta
Beura S, Majhi B, Dash R (2015) Mammogram classification using two-dimensional discrete wavelet transform and gray-level co-occurrence matrix for detection of breast cancer. Neurocomputing 154:1–14
Bruno DOT, Nascimento do, Ramos MZ, Batista RP, Neves VR, L. A., & Martins AS (2016) LBP operators on curvelet coefficients as an algorithm to describe texture in breast cancer tissues. Expert Syst Appl 55:329–340
Chakraborty J, Midya A, Rabidas R (2018) Computer-aided detection and diagnosis of mammographic masses using multi-resolution analysis of oriented tissue patterns. Expert Syst Appl 99:168–179
Cheng HD, Cai X, Chen X, Hu L, Lou X (2003) Computer-aided detection and classification of microcalcifications in mammograms: a survey. Pattern Recognit 36(12):2967–2991
Cvetković J, Nenadović M (2016) Depression in breast cancer patients. Psychiatry Res 240:343–347
Darwish A, Hassanien AE, Elhoseny M, Sangaiah AK, Muhammad K (2017) The impact of the hybrid platform of internet of things and cloud computing on healthcare systems: opportunities, challenges, and open problems. J Ambient Intell Humaniz Comput. https://doi.org/10.1007/s12652-017-0659-1
Dhahbi S, Barhoumi W, Zagrouba E (2015) Breast cancer diagnosis in digitized mammograms using curvelet moments. Comput Biol Med 64:79–90
Elhoseny M, Ramírez-González G, Abu-Elnasr OM, Shawkat SA, Arunkumar N, Farouk A (2018) Secure medical data transmission model for IoT-based healthcare systems. IEEE Access 6:20596–20608. https://doi.org/10.1109/ACCESS.2018.2817615
Elhoseny M, Abdelaziz A, Salama AS, Riad AM, Muhammad K, Sangaiah AK (2018) A hybrid model of Internet of Things and cloud computing to manage big data in health services applications. Future Gener Comput Syst. https://doi.org/10.1016/j.future.2018.03.005
Eltoukhy MM, Faye I (2013) An adaptive threshold method for mass detection in mammographic images. In: 2013 IEEE international conference on signal and image processing applications (ICSIPA). IEEE, Piscataway, pp 374–378
Eltoukhy MM, Faye I (2014) An optimized feature selection method for breast cancer diagnosis in digital mammogram using multiresolution representation. Appl Math Inf Sci 8(6):2921
Eltoukhy MM, Faye I, Samir BB (2010a) Curvelet based feature extraction method for breast cancer diagnosis in digital mammogram. In: 2010 International conference on intelligent and advanced systems (ICIAS). IEEE, Piscataway, pp 1–5
Eltoukhy MM, Faye I, Samir BB (2010b) A comparison of wavelet and curvelet for breast cancer diagnosis in digital mammogram. Comput Biol Med 40(4):384–391
Eltoukhy MM, Faye I, Samir BB (2012) A statistical based feature extraction method for breast cancer diagnosis in digital mammogram using multiresolution representation. Comput Biol Med 42(1):123–128
Flusser J, Zitova B, Suk T (2009) Moments and moment invariants in pattern recognition. Wiley, New York
Gedik N (2016) A new feature extraction method based on multi-resolution representations of mammograms. Appl Soft Comput 44:128–133
Hastie T, Tibshirani R, Friedman J (2016) The elements of statistical, data mining, inference, and prediction, 2nd edn. Springer Science, Berlin
Hosny KM (2007) Exact and fast computation of geometric moments for gray level images. Appl Math Comput 189(2):1214–1222
Hosny KM (2010) Robust template matching using orthogonal Legendre moment invariants. J Comput Sci 6(10):1083
Hosny KM (2012) Fast computation of accurate Gaussian–Hermite moments for image processing applications. Digit Signal Process 22(3):476–485
Jiao Z, Gao X, Wang Y, Li J (2016) A deep feature based framework for breast masses classification. Neurocomputing 197:221–231
Khan S, Hussain M, Aboalsamh H, Mathkour H, Bebis G, Zakariah M (2016) Optimized Gabor features for mass classification in mammography. Appl Soft Comput 44:267–280
Lajevardi SM, Hussain ZM (2010) Higher order orthogonal moments for invariant facial expression recognition. Digit Signal Process 20(6):1771–1779
MIAS (2017) http://www.wiau.man.ac.uk/services/MIAS/MIASweb.html. Visited Sept 2017
Raghavendra U, Acharya UR, Fujita H, Gudigar A, Tan JH, Chokkadi S (2016) Application of Gabor wavelet and locality sensitive discriminant analysis for automated identification of breast cancer using digitized mammogram images. Appl Soft Comput 46:151–161
Rahman SM, Reza MM, Hasani QZ (2013) Low-complexity iris recognition method using 2D Gauss–Hermite moments. In: 2013 8th International symposium on image and signal processing and analysis (ISPA). IEEE, Piscataway, pp 142–146
Sajjad M, Nasir M, Muhammad K, Khan S, Jan Z, Sangaiah AK, … Baik SW (2017) Raspberry Pi assisted face recognition framework for enhanced law-enforcement services in smart cities. Future Gener Comput Syst
Sharma S, Khanna P (2015) Computer-aided diagnosis of malignant mammograms using Zernike moments and SVM. J Digit Imaging 28(1):77–90
Shehab A, Elhoseny M, Muhammad K, Sangaiah AK, Yang P, Huang H, Hou G (2018) Secure and robust fragile watermarking scheme for medical images. IEEE Access 6:10269–10278
Shen J, Shen W, Shen D (2000) On geometric and orthogonal moments. Int J Pattern Recognit Artif Intell 14(07):875–894
Wang L, Dai M (2007) Application of a new type of singular points in fingerprint classification. Pattern Recognit Lett 28(13):1640–1650
Wu Y, Shen J (2005) Properties of orthogonal Gaussian–Hermite moments and their applications. EURASIP J Appl Signal Process 2005, 588–599
Yang B, Dai M (2011) Image analysis by Gaussian–Hermite moments. Signal Process 91(10):2290–2303
Yang B, Li G, Zhang H, Dai M (2011) Rotation and translation invariants of Gaussian–Hermite moments. Pattern Recognit Lett 32(9):1283–1298
Yang B, Flusser J, Suk T (2015) Design of high-order rotation invariants from Gaussian–Hermite moments. Sig Process 113:61–67
Zyout I, Czajkowska J, Grzegorzek M (2015) Multi-scale textural feature extraction and particle swarm optimization based model selection for false positive reduction in mammography. Comput Med Imaging Graph 46:95–107
Acknowledgements
The IRMA dataset used in this study was used by courtesy of Thomas M. Deserno, Department of Medical Informatics, Aachen, Germany. In addition, we would like to thank Dr. Mohamed Tahoun and Dr. S. J. Gardezi for their discussion and invaluable comments.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Eltoukhy, M.M., Elhoseny, M., Hosny, K.M. et al. Computer aided detection of mammographic mass using exact Gaussian–Hermite moments. J Ambient Intell Human Comput 15, 1139–1147 (2024). https://doi.org/10.1007/s12652-018-0905-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12652-018-0905-1