RETRACTED ARTICLE: Repair of Buckled Concrete Filled Steel Tube Columns Subjected to Axial Compression

  • Structural Engineering
  • Published:
KSCE Journal of Civil Engineering Aims and scope

This article was retracted on 15 April 2020

This article has been updated

Abstract

Concrete filled steel tube (CFST) columns are the main loaded elements in the structures as they provoke the superior mechanical properties of constituent materials. However, concrete filled double steel tube (CFDST) columns refer to a new type of composite elements which have very high level of fire resistance and the potential to be implemented in high-rise structures. Columns are exposed to high stresses due to the increasing loads of daily life. Therefore, unpredictable deformations may occur and affect the performance and safety of structures. This article first studies the effectiveness of a concrete filled circular steel tube (CFCST)-based technique for repairing buckled and stressed CFST columns, then it studies the advantages of CFDST columns in improving the capability of composite members. The CFCST-based repairing system is to place the deformed CFST column in a larger diameter steel tube, and then the concrete is poured in the gap between the deformed column and the larger tube. Buckled CFST specimens with different tube tkicknesses were repaired and tested to failure under axial compression. The performance of repaired CFST columns was compared with that of undamaged counterpart columns. Based on findings, it can be concluded that the repair technique restored the capacity of the deformed columns from 97% to 100% of the capacity of the undamaged counterpart columns which confirm the effectiveness of repairing using CFCST-based technique. Results of the study provide significant information to the available test data concerning repairing of CFST members.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Change history

  • 15 April 2020

    The Editor-in-Chief of the <Emphasis Type="Italic">KSCE Journal of Civil Engineering</Emphasis> has retracted the article “Repair of Buckled Concrete Filled Steel Tube Columns Subjected to Axial Compression” published in Volume 24, No. 5, May 2020. After a thorough investigation, it has been established that consent was not obtained from the co-authors prior to the submission of the manuscript. Therefore, the Editor-in-Chief has retracted this article from the literature because of a breach of the Journal’s authorship policy in accordance with the Code of Research Ethics of the Korean Society of Civil Engineers. Author Ahmed Almasslawi does not agree with this retraction. Author Talha Ekmekyapar agrees with this retraction. Author Baraa J.M. AL-Eliwi has not responded to any correspondence from the editor or publisher about this retraction.

References

  • AISC 360-10 (2010a) Specification for structural steel buildings. N. 360-10, American Institute of Steel Construction, Chicago, IL, USA

    Google Scholar 

  • AISC 360-10 (2010b) Commentary on the specification for structural steel buildings. N. 360-10, American Institute of Steel Construction, Chicago, IL, USA

    Google Scholar 

  • AL-Eliwi BJ, Ekmekyapar T, Faraj RH, Gogus MT, AL-Shaar AA (2017) Performance of lightweight aggregate and self-compacted concrete-filled steel tube columns. Steel and Composite Structures, 25(3):299–314, DOI: 10.12989/scs.2017.25.3.299

    Google Scholar 

  • ASTM C39/C39M-14a (2014) Standard test method for compressive strength of cylindrical concrete specimens. ASTM C39/C39M-14a, ASTM International, West Conshohocken, PA, USA

    Google Scholar 

  • ASTM E8/E8M-15a (2015) Standard test method for tension testing of metallic materials. ASTM E8/E8M-15a, ASTM International, West Conshohocken, PA, USA

    Google Scholar 

  • Chang X, Luo X, Zhu C, Tang C (2014) Analysis of circular concrete-filled steel tube (CFT) support in high ground stress conditions. Tunnelling and Underground Space Technology 43:41–48, DOI: 10.1016/j.tust.2014.04.002

    Article  Google Scholar 

  • Dong JF, Wang QY, Guan ZW (2013) Structural behaviour of recycled aggregate concrete filled steel tube columns strengthened by CFRP. Engineering Structures 48:532–542, DOI: 10.1016/j.engstruct.2012. 11.006

    Article  Google Scholar 

  • Ekmekyapar T, Al-Eliwi BJ (2017) Concrete filled double circular steel tube (CFDCST) stub columns. Engineering Structures 135:68–80, DOI:10.1016/j.engstruct.2016.12.061

    Article  Google Scholar 

  • Espinos A, Romero ML, Lam D (2016) Fire performance of innovative steel-concrete composite columns using high strength steels. Thin-Walled Structures 106:113–128, DOI: 10.1016/j.tws.2016.04.014

    Article  Google Scholar 

  • EN 1992-1-1 (2004) Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings. EN 1992-1-1, British Standard Institution, London, UK

    Google Scholar 

  • EN 1993-1-1 (2005) Eurocode 3: Design of steel structures - Part 1-1: General rules and rules for buildings. EN 1993-1-1, British Standard Institution, London, UK

    Google Scholar 

  • Han LH (2007) Concrete-filled steel tubular structures-theory and practice, 2nd edition. China Science Press, Beijing, China (in Chinese)

    Google Scholar 

  • Han LH, Li W, Bjorhovde R (2014) Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members. Journal of Constructional Steel Research 100:211–228, DOI: 10.1016/j.jcsr.2014.04.016

    Article  Google Scholar 

  • Han LH, Lin XK, Wang YC (2006) Cyclic performance of repaired concrete-filled steel tubular columns after exposure to fire. Thin-Walled Structures 44(10):1063–1076, DOI: 10.1016/j.tws.2006.10.001

    Article  Google Scholar 

  • Hassanein MF, Elchalakani M, Patel VI (2017) Overall buckling behaviour of circular concrete-filled dual steel tubular columns with stainless steel external tubes. Thin-Walled Structures 115:336–348, DOI: 10.1016/j.tws.2017.01.035

    Article  Google Scholar 

  • Johansson M (2002) The efficiency of passive confinement in CFT columns. Steel and Composite Structures 2:379–396, DOI: 10.12989/ scs.2002.2.5.379

    Article  Google Scholar 

  • Kaya A, Dawood M, Gencturk B (2015) Repair of corroded and buckled short steel columns using concrete-filled GFRP jackets. Construction and Building Materials 94:20–27, DOI: 10.1016/j.conbuildmat.2015.06.040

    Article  Google Scholar 

  • Kibriya T (2017) Performance of concrete filled steel tubular columns. American Journal of Civil Engineering and Architecture 5:35–39

    Google Scholar 

  • Kuranovas A, Kvedaras AK (2007) Behaviour of hollow concrete-filled steel tubular composite elements. Journal of Civil Engineering and Management 13:131–141

    Article  Google Scholar 

  • Kwon YB, Seo SJ, Kang DW (2011) Prediction of the squash loads of concrete-filled tubular section columns with local buckling. Thin-Walled Structures 49:85–93, DOI: 10.1016/j.tws.2010.08.009

    Article  Google Scholar 

  • Li S, Liu Z, Lu Y, Zhu T (2017) Shear performance of steel fibers reinforced self-confinement and self-compacting concrete-filled steel tube stub columns. Construction and Building Materials 147:758–775, DOI: 10.1016/j.conbuildmat.2017.04.192

    Article  Google Scholar 

  • Lie TT, Stringer DC (1994) Calculation of the fire resistance of steel hollow structural section columns filled with plain concrete. Canadian Journal of Civil Engineering 21(3):382–385, DOI: 10.1139/194-041

    Article  Google Scholar 

  • Liu H, Wang Y, He M, Shi Y, Waisman H (2015) Strength and ductility performance of concrete-filled steel tubular columns after long-term service loading. Engineering Structures 100:308–325, DOI: 10.1016/j.engstruct.2015.06.024

    Article  Google Scholar 

  • Lu H, Han LH, Zhao XL (2010) Fire performance of self-consolidating concrete filled double skin steel tubular columns: Experiments. Fire Safety Journal 45(2):106–115, DOI: 10.1016/j.firesaf.2009.12.001

    Article  Google Scholar 

  • Pons D, Espinos A, Albero V, Romero ML (2018) Numerical study on axially loaded ultra-high strength concrete-filled dual steel columns. Steel and Composite Structures 26(6):705–717, DOI: 10.12989/scs.2018.26.6.705

    Google Scholar 

  • Romero ML, Espinos A, Portoles JM, Hospitaler A, Ibanez C (2015) Slender double-tube ultra-high strength concrete-filled tubular columns under ambient temperature and fire. Engineering Structures 99:536–545, DOI: 10.1016/j.engstruct.2015.05.026

    Article  Google Scholar 

  • Romero ML, Ibanez C, Espinos A, Portoles JM, Hospitaler A (2017) Influence of ultra-high strength concrete on circular concrete-filled dual steel columns. Structures 9:13–20, DOI: 10.1016/j.istruc.2016.07.001

    Article  Google Scholar 

  • Tao Z, Han LH (2007) Behaviour of fire-exposed concrete-filled steel tubular beam columns repaired with CFRP wraps. Thin-walled Structures 45(1):63–76, DOI: 10.1016/j.tws.2006.11.004

    Article  Google Scholar 

  • Tao Z, Han LH, Wang LL (2007a) Compressive and flexural behaviour of CFRP-repaired concrete-filled steel tubes after exposure to fire. Journal of Constructional Steel Research 63(8):1116–1126, DOI: 10.1016/j.jcsr.2006.09.007

    Article  Google Scholar 

  • Tao Z, Han LH, Zhuang JP (2007b) Axial loading behavior of CFRP strengthened concrete-filled steel tubular stub columns. Advances in Structural Engineering 10(1):37–46, DOI: 10.1260/136943307780150814

    Article  Google Scholar 

  • Wan CY, Zha XX (2016) Nonlinear analysis and design of concrete-filled dual steel tubular columns under axial loading. Steel and Composite Structures 20(3):571–597, DOI: 10.12989/scs.2016.20.3.571

    Article  Google Scholar 

  • Wang ZB, Tao Z, Yu Q (2017) Axial compressive behaviour of concrete-filled double-tube stub columns with stiffeners. Thin-Walled Structures, 120:91–104, DOI: 10.1016/j.tws.2017.08.025

    Article  Google Scholar 

  • Zheng Y, Tao Z (2019) Compressive strength and stiffness of concrete-filled double-tube columns. Thin-Walled Structures 134:174–188, DOI: 10.1016/j.tws.2018.10.019

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ahmed Almasslawi.

Additional information

The Editor-in-Chief of the KSCE Journal of Civil Engineering has retracted the article “Repair of Buckled Concrete Filled Steel Tube Columns Subjected to Axial Compression” published in Volume 24, No. 5, May 2020. After a thorough investigation, it has been established that consent was not obtained from the co-authors prior to the submission of the manuscript. Therefore, the Editor-in-Chief has retracted this article from the literature because of a breach of the Journal's authorship policy in accordance with the Code of Research Ethics of the Korean Society of Civil Engineers. Ahmed Almasslawi does not agree with this retraction. Talha Ekmekyapar agrees with this retraction. Baraa J.M. AL-Eliwi has not responded to any correspondence from the editor or publisher about this retraction.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Almasslawi, A., Ekmekyapar, T. & AL-Eliwi, B.J. RETRACTED ARTICLE: Repair of Buckled Concrete Filled Steel Tube Columns Subjected to Axial Compression. KSCE J Civ Eng 24, 1499–1508 (2020). https://doi.org/10.1007/s12205-020-0321-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12205-020-0321-x

Keywords

Navigation