We herein report a new procedure to prevent type 3 endoleakage (EL3) after open stent graft (OSG) surgery with thoracic endovascular aortic repair (TEVAR) extension. The OSG Dacron graft portion is reversed and folded inside the OSG stent graft portion intraoperatively, filling the crack between the OSG and TEVAR device. We applied this procedure in two patients with no postoperative complications. Our folding procedure may prevent EL3 after OSG surgery if TEVAR extension is needed in the future.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Koizumi S, Nagasawa A, Koyama T. Total aortic arch replacement using frozen elephant trunk technique with J Graft Open Stent Graft for distal aortic arch aneurysm. Gen Thorac Cardiovasc Surg. 2018;66(2):91–4.

    Article  Google Scholar 

  2. Roselli EE, Idrees JJ, Bakaeen FG, Tong MZ, Soltesz EG, Mick S, et al. Evolution of simplified frozen elephant trunk repair for acute DeBakey Type I dissection: midterm outcomes. Ann Thorac Surg. 2018;105(3):749–55.

    Article  Google Scholar 

  3. Pantaleo A, Jafrancesco G, Buia F, Leone A, Lovato L, Russo V, et al. Distal Stent Graft-induced new entry: an emerging complication of endovascular treatment in aortic dissection. Ann Thorac Surg. 2016;102(2):527–32.

    Article  Google Scholar 

Download references

Acknowledgements

We thank Angela Morben, DVM, ELS, from Edanz Group (http://www.edanzediting.com/ac), for editing a draft of this manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tatushi Onzuka.

Ethics declarations

Conflict of interest

Tatushi Onzuka, Kojiro Furukawa, Eiki Tayama, Shigeki Morita, and Akira Shiose declare that no conflict of interest exists.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Onzuka, T., Furukawa, K., Tayama, E. et al. Folding procedure to diminish type 3 endoleakage after open stent graft surgery with TEVAR extension. Gen Thorac Cardiovasc Surg 67, 999–1000 (2019). https://doi.org/10.1007/s11748-019-01115-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11748-019-01115-5

Keywords

Navigation