Aortic valve replacement for aortic stenosis in the elderly: influence of prosthesis-patient mismatch on late survival and left ventricular mass regression

  • Original Article
  • Published:
General Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

Purpose

Controversy still exists about the influence of prosthesis-patient mismatch on outcomes after aortic valve replacement in the elderly. Our aim was to evaluate the effect of prosthesis-patient mismatch on survival and the extent of left ventricular (LV) mass regression after aortic valve replacement for aortic stenosis in Japanese patients aged ≥65 years.

Materials and methods

A total of 84 patients who underwent isolated aortic valve replacement for aortic stenosis between 1986 and 2006 were retrospectively analyzed. Patients were divided into two groups based on the definition of prosthesis-patient mismatch (indexed effective orifice area ≤0.85 cm2/m2), and long-term results were compared. The mean follow-up time was 4.5 ± 4.5 years. In 49 patients, follow-up echocardiography was performed at least 6 months after surgery, and the extent of LV mass regression was analyzed according to the presence of a prosthesis-patient mismatch.

Results

Eight years after surgery, there was no significant difference between patients with and without mismatch in terms of actuarial freedom from cardiac-related death (P = 0.159) or death from any valve-related events (P = 0.107). The postoperative transvalvular pressure gradients were not significantly different between the two groups, and significant absolute and relative LV mass regression were observed in both groups.

Conclusion

Although a moderate prosthesis-patient mismatch appeared to be tolerable, the criteria of prosthesis-patient mismatch may have to be reassessed for elderly Japanese patients.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Sundt TM, Bailey MS, Moon MR, Mendeloff EN, Huddleston CB, Pasque MK, et al. Quality of life after aortic valve replacement at the age of >80 years. Circulation 2000;102(suppl III):70–74.

    Google Scholar 

  2. Carrier M, Pellerin M, Perrault LP, Hebert Y, Page P, Cartier R, et al. Experience with the 19-mm Carpentier-Edwards pericardial bioprosthesis in the elderly. Ann Thorac Surg 2001;71:S249–S252.

    Article  PubMed  CAS  Google Scholar 

  3. Freed DH, Tam JW, Moon MC, Harding GEJ, Ahmad E, Pascoe EA. Nineteen-millimeter prosthetic aortic valves allow normalization of left ventricular mass in elderly women. Ann Thorac Surg 2002;74:2022–2025.

    Article  PubMed  Google Scholar 

  4. Vitale N, Clark SC, Ramsden A, Hasan A, Hilton CJ, Holden MP. Clinical and hemodynamic evaluation of small perimount aortic valves in patients aged 75 years or older. Ann Thorac Surg 2003;75:35–40.

    Article  PubMed  Google Scholar 

  5. Melby SJ, Zierer A, Kaiser SP, Guthrie TJ, Keune JD, Schuessler RB, et al. Aortic valve replacement in octogenarians: risk factors for early and late mortality. Ann Thorac Surg 2007;83:1651–1657.

    Article  PubMed  Google Scholar 

  6. Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978;58:20–24.

    PubMed  CAS  Google Scholar 

  7. Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000;36:1131–1141.

    Article  PubMed  CAS  Google Scholar 

  8. Del Rizzo DF, Abdoh A, Cartier P, Doty D, Westaby S. Factors affecting left ventricular mass regression after aortic valve replacement with stentless valves. Semin Thorac Cardiovasc Surg 1999;11(suppl 1):114–120.

    PubMed  Google Scholar 

  9. Tasca G, Brunelli F, Cirillo M, Dalla Tomba M, Mhagna Z, Troise G, et al. Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement. Ann Thorac Surg 2005;79:505–510.

    Article  PubMed  Google Scholar 

  10. Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 2003;108: 983–988.

    Article  PubMed  Google Scholar 

  11. Ruel M, Rubens FD, Masters RG, Pipe AL, Bedard P, Hendy PJ, et al. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves. J Thorac Cardiovasc Surg 2004;127:149–159.

    Article  PubMed  Google Scholar 

  12. Tasca G, Mhagna Z, Perotti S, Centurini PB, Sabatini T, Amaducci A, et al. Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation 2006;113:570–576.

    Article  PubMed  Google Scholar 

  13. Moon MR, Pasque MK, Munfakh NA, Melby SJ, Lawton JS, Moazami N, et al. Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival. Ann Thorac Surg 2006;81:481–489.

    Article  PubMed  Google Scholar 

  14. Mohty-Echahidi D, Malouf JF, Girard SE, Schaff HV, Grill DE, Enriquez-Sarano ME, et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St. Jude Medical mechanical prostheses in the aortic position. Circulation 2006;113:420–426.

    Article  PubMed  Google Scholar 

  15. Izzat MB, Kadir I, Reeves B, Wilde P, Bryan AJ, Angelini GD. Patient-prosthesis mismatch is negligible with modern small-size aortic valve prostheses. Ann Thorac Surg 1999;68: 1657–1660.

    Article  PubMed  CAS  Google Scholar 

  16. Hanayama N, Christakis GT, Mallidi HR, Joyner CD, Fremes SE, Morgan CD, et al. Patient prosthesis mismatch is rare after aortic valve replacement: valve size may be irrelevant. Ann Thorac Surg 2002;73:1822–1829.

    Article  PubMed  Google Scholar 

  17. Kato Y, Suehiro S, Shibata T, Sasaki Y, Hirai H. Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis. J Card Surg 2007;22:314–319.

    Article  PubMed  Google Scholar 

  18. Amarelli C, Della Corte A, Romano G, Iasevoli G, Dialetto G, De Santo LS, et al. Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis. J Thorac Cardiovasc Surg 2005;129:512–517.

    Article  PubMed  Google Scholar 

  19. Roscitano A, Benedetto U, Sciangula A, Merico E, Barberi F, Bianchini R, et al. Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly. Eur J Cardiothorac Surg 2006;29: 139–143.

    Article  PubMed  Google Scholar 

  20. Howell NJ, Keogh BE, Barnet V, Bonser RS, Graham TR, Rooney SJ, et al. Patient-prosthesis mismatch does not affect survival following aortic valve replacement. Eur J Cardiothorac Surg 2006;30:10–14.

    Article  PubMed  Google Scholar 

  21. Edmunds LH Jr, Clark RE, Cohn LH, Grunkemeier GL, Miller DC, Weisel RD. Guidelines for reporting morbidity and mortality after cardiac valvular operations. J Thorac Cardiovasc Surg 1996;112:708–711.

    Article  PubMed  Google Scholar 

  22. Devereux RB, Alonso DR, Lutas EM, Gottlieb GJ, Campo E, Sachs I, et al. Echocardiographic assessment of left ventricular hypertrophy: comparison to necropsy findings. Am J Cardiol 1986;57:450–458.

    Article  PubMed  CAS  Google Scholar 

  23. Okin PM, Devereux RB, Nieminen MS, Jern S, Oikarinen L, Viitasalo M, et al. Relationship of the electrocardiographic strain pattern to left ventricular structure and function in hypertensive patients: the LIFE study. J Am Coll Cardiol 2001;38:514–520.

    Article  PubMed  CAS  Google Scholar 

  24. Ross J Jr, Braunwald E. Aortic stenosis. Circulation 1968; 38(suppl):V61–V67.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yasuyuki Kato.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kato, Y., Tsutsumi, Y., Kawai, T. et al. Aortic valve replacement for aortic stenosis in the elderly: influence of prosthesis-patient mismatch on late survival and left ventricular mass regression. Gen Thorac Cardiovasc Surg 56, 397–403 (2008). https://doi.org/10.1007/s11748-008-0261-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11748-008-0261-8

Key words

Navigation