Skip to main content

Advertisement

Log in

Biomonitorization of metal ions in the serum of Iranian patients treated with fixed orthodontic appliances in comparison with controls in eastern Iran

  • Research Article
  • Published:
Environmental Science and Pollution Research Aims and scope Submit manuscript

Abstract

The present study aimed to assess the level of metal ions [chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), and zinc (Zn)] in the serum of patients with fixed orthodontic appliances. One hundred samples (32 males, 68 females) were collected from patients undergoing fixed orthodontic treatment for different periods. A reference (control) group (24 males, 16 females) who had no appliances was used to properly evaluate the changes in the level of these elements in orthodontic appliance users. The element concentrations were measured using inductively coupled plasma mass spectrometry (ICP-MS). Higher concentrations of metal ions (except for Cr) were found in the serum of the orthodontic group. Bivariate scatter plot showed a highly significant (p < 0.001) correlation between Ni and other elements. The duration of orthodontic treatment increased significantly the Ni levels whereas the bracket type was found to have no significant impact on altering the concentration level of metal ions. The results of the SEM-EDS showed a high variation in the level of metal ions in the brackets and wires. In conclusion, fixed orthodontic appliances increased serum levels of Ni, Zn, Mn, Fe, and Cu but did not change Cr levels.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  • Ağaoğlu G, Arun T, Izgu B, Yarat A (2001) Nickel and chromium levels in the saliva and serum of patients with fixed orthodontic appliances. Angle Orthod 71:375–379

    Google Scholar 

  • Ahlstrom MG, Thyssen JP, Menne T, Johansen JD (2017) Prevalence of nickel allergy in Europe following the EU Nickel Directive—a review. Cont Dermat 77:193–200

    Article  CAS  Google Scholar 

  • Amini F, Rakhshan V, Sadeghi P (2012a) Effect of fixed orthodontic therapy on urinary nickel levels: a long-term retrospective cohort study. Biol Trace Elem Res 150:31–36

    Article  CAS  Google Scholar 

  • Amini F, Jafari A, Amini P, Sepasi S (2012b) Metal ion release from fixed orthodontic appliances—an in vivo study. Eur J Orthod 34:126–130. https://doi.org/10.1093/ejo/cjq181

    Article  Google Scholar 

  • Amini F, Rakhshan V, Pousti M, Rahimi H, Shariati M, Aghamohamadi B (2012c) Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study. Korean J Orthod 42:129–137

    Article  Google Scholar 

  • Amini F, Harandi S, Mollaei M, Rakhshan V (2015) Effects of fixed orthodontic treatment using conventional versus metal-injection molding brackets on salivary nickel and chromium levels: a double-blind randomized clinical trial. Eur J Orthod 37:522–530

    Article  Google Scholar 

  • Barrett R, Bishara SE, Quinn JK (1993) Biodegradation of orthodontic appliances. Part I Biodegradation of nickel and chromium in vitro. Am J Orthod Dentofacial Orthop 103:8–14

    Article  CAS  Google Scholar 

  • Cantekin K, Celikoglu M, Karadas M, Yildirim H, Erdem A (2011) Effects of orthodontic treatment with fixed appliances on oral health status: a comprehensive study. J Dent Sci 6:235–238

    Article  Google Scholar 

  • Downarowicz P, Mikulewicz M (2017) Trace metal ions release from fixed orthodontic appliances and DNA damage in oral mucosa cells by in vivo studies: a literature review. Adv. Clin. Exp. Med.: Off. Organ Wroclaw Med Univ 26:1155–1162

    Google Scholar 

  • Ebrahim AM, Eltayeb M, Benker B, Grill P, Attahir M, Osman A, Elsadig M, Micha B (2011) Study on some trace element contents in serum and nail samples obtained from Sudanese subjects. Biol Trace Elem Res 144:225–233

    Article  CAS  Google Scholar 

  • EPA (1999) Method IO-3.3 determination of metals in ambient particulate matter using X-ray fluorescence (XRF) spectroscopy, In: Compendium of methods for the determination of inorganic compounds in ambient air, EPA/625/R-96/010a, Environmental Protection Development.

  • Fernandez-Minano E, Ortiz C, Vicente A, Calvo JL, Ortiz AJ (2011) Metallic ion content and damage to the DNA in oral mucosa cells of children with fixed orthodontic appliances. Biometals. 24:935–941

    Article  CAS  Google Scholar 

  • Feu D, Miguel JA, Celeste RK, Oliveira BH (2013) Effect of orthodontic treatment on oral health-related quality of life. Angle Orthod 83:892–898

    Article  Google Scholar 

  • Grimsdottir MR, Gjerdet NR, Hensten-Pettersen A (1992) Composition and in vitro corrosion of orthodontic appliances. Am J Orthod Dentofac Orthop 101:525–532

    Article  CAS  Google Scholar 

  • Hafez HS, Selim EMN, Eid FHK, Tawfik WA, Al-Ashkar EA, Mostafa YA (2011) Cytotoxicity, genotoxicity, and metal release in patients with fixed orthodontic appliances: a longitudinal in-vivo study. Am J Orthod Dentofac Orthop 140:298–308

    Article  Google Scholar 

  • Heravi F, Abbaszadegan MR, Merati M, Hasanzadeh N, Dadkhah E, Ahrari F (2013) DNA damage in oral mucosa cells of patients with fixed orthodontic appliances. J Dent 10:494–500

    Google Scholar 

  • Hunt CE, Baumgart H, Gosele U, Abe T (2001) Semiconductor wafer bonding: science, technology, and applications V. Proceedings of the International Symposia. Electrochem. Soc, Pennington, p 480

    Google Scholar 

  • Hwang CJ, Shin JS, Cha JY (2001) Metal release from simulated fixed orthodontic appliances. Am J Orthod Dentofac Orthop 120:383–391

    Article  CAS  Google Scholar 

  • IARC. IARC Monogr Eval Carcinog Risks Hum, Vol 100C, Arsenic, metals, fibers and dusts. Lyon, France: International Agency for Research on Cancer; 2012. https://monographs.iarc.fr/iarc-monographs-on-the-evaluation-of-carcinogenic-risks-to-humans-19/. Accessed 10 July 2019.

  • Jacob SE, Goldenberg A, Pelletier JL, Fonacier LS, Usatine R, Silverberg N (2015) Nickel allergy and our children’s health: a review of indexed cases and a view of future prevention. Pediatr Dermatol 32:779–785

    Article  Google Scholar 

  • Jaishankar M, Tseten T, Anbalagan N, Mathew BB, Beeregowda KN (2014) Toxicity, mechanism and health effects of some heavy metals. Interdiscip Toxicol 7:60–72

    Article  CAS  Google Scholar 

  • Kayan M, Nazıroglu M, Barak C (2010) Effects of vitamins C and E combination on element levels in blood of smoker and nonsmoker radiology X-ray technicians. Biol Trace Elem Res 136:140–148

    Article  CAS  Google Scholar 

  • Kim H, Johnson JW (1999) Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires. Angle Orthod 69:39–44

    CAS  Google Scholar 

  • Liu Y, Liu S, Mao J, Piao S, Qin J, Peng S, Xie X, Guan H, Li Y, Shan Z, Teng W (2018) Serum trace elements profile in Graves’ disease patients with or without orbitopathy in Northeast China. Biomed Res Int 2018:1–8

    Google Scholar 

  • Luo J, Hendryx M (2014) Relationship between blood cadmium, lead and serum thyroid measures in US adults—the National Health and Nutrition Examination Survey (NHANES) 2007-2010. Int J Environ Health Res doi 24:125–136. https://doi.org/10.1080/09603123.2013.800962

    Article  CAS  Google Scholar 

  • Macedo L, Cardoso C (2010) The release of ions from metallic orthodontic appliances. Semin Orthod 16:282–292

    Article  Google Scholar 

  • Malkondu O, Karapinar Kazandag M, Kazazoglu E (2014) A review on Biodentine, a contemporary dentine replacement and repair material. Biomed Res Int 2014:160951

    Article  CAS  Google Scholar 

  • Martín-Camean A, Molina-Villalba I, Jos A, Iglesias-Linares A, Solano E, Camean AM, Gil F (2014) Biomonitorization of chromium, copper, iron, manganese and nickel in scalp hair from orthodontic patients by atomic absorption spectrometry. Environ Toxicol Pharmacol 37:759–771

    Article  CAS  Google Scholar 

  • Mendes BDA, Neto Ferreira RA, Pithon MM, Horta MC, Oliveira DD (2014) Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study. J Appl Oral Sci 22:194–203

    Article  Google Scholar 

  • Menezes L, Quintao C, Bolognese A (2007) Urinary excretion level of nickel in orthodontic patients. Am J Orthod Dentofac Orthop 131:635–638

    Article  Google Scholar 

  • Menezes LMD, Souza RMD, Dolci GS, Dedavid BA (2010) Analysis of biodegradation of orthodontic brackets using scanning electron microscopy. Dental Press J Orthod 15:48–51

    Article  Google Scholar 

  • Mikulewicz M, Chojnacka K (2011) Release of metal ions from orthodontic appliances by in vitro studies: a systematic literature review. Biol Trace Elem Res 139:241–256

    Article  CAS  Google Scholar 

  • Mikulewicz M, Wołowiec P, Janeczek M, Gedrange T, Chojnacka K (2014) The release of metal ions from orthodontic appliances animal tests. Angle Orthod 84:673–679

    Article  Google Scholar 

  • Mikulewicz M, Wolowicc P, Loster B, Chojnacka K (2015) Metal ion released from fixed orthodontic appliance affect hair mineral content. Biol Trace Elem Res 163:11–18

    Article  CAS  Google Scholar 

  • Ma’or Z, Halicz L, Portugal-Cohen M, Russo MZ, Robino F, Vanhaecke T (2015) Safety evaluation of traces of nickel and chrome in cosmetics: the case of Dead Sea mud. Regul Toxicol Pharmacol 73:797–801

    Article  CAS  Google Scholar 

  • Masjedi MK, Jahromi NH, Niknam O, Hormozi E, Rikhsan V (2017) Effects of fixed orthodontic treatment using conventional (two-piece) versus metal injection moulding brackets on hair nickel and chromium level: a double-blind randomized clinical trial. Eur J Orthod 39:17–24

    Article  Google Scholar 

  • Mudjari S, Achmad MH (2018) Comparison between nickel and chromium levels in serum and urine in patients treated with fixed orthodontic appliances: a longitudinal study. Brazil Res Ped Dent Integr Clin 18(1):e4071

    Article  Google Scholar 

  • Oliveira PG, Tavares RR, Freitas JC (2013) Assessment of motivation, expectations and satisfaction of adult patients submitted to orthodontic treatment. Dental Press J Orthod 18:81–87

    Article  Google Scholar 

  • Ortiz AJ, Fernandez E, Vicente A, Calvo JL, Ortiz C (2011) Metallic ions released from stainless steel, nickel-free, and titanium orthodontic alloys: toxicity and DNA damage. Am J Orthod Dentofac Orthop 140:115–122

    Article  Google Scholar 

  • Pabari S, Moles DR, Cunningham SJ (2011) Assessment of motivation and psychological characteristics in adult orthodontic patients. Am J Orthod Dentofac Orthop 140:263–272

    Article  Google Scholar 

  • Pazzini CA, Oliveira Júnior G, Marques LS, Pereira CV, Pereira LJ (2009) Prevalence of nickel allergy and longitudinal evaluation of periodontal abnormalities in orthodontic allergic patients. Angle Orthod 79:922–927

    Article  Google Scholar 

  • Pechova A, Pavlata L (2007) Chromium as an essential nutrient: a review. Vet Med 52:1–18

    Article  CAS  Google Scholar 

  • Rai RV, Shetty S, Ahluwalia R, George S (2011) Quantitative assessment of serum nickel and chromium levels in orthodontic patients: an in vivo study. J Indian Orthod Soc 45(4):251–255

    Article  Google Scholar 

  • Regis SJ, Soares P, Camargo ES, Guariza Filho O, Tanaka O, Maruo H (2011) Biodegradation of orthodontic metallic brackets and associated implications for friction. Am J Orthod Dentofac Orthop 140:501–509

    Article  Google Scholar 

  • Satija A, Sidhu MS, Grover S, Malik V, Yadav P, Diwakar R (2014) Evaluation of salivary and serum concentration of nickel and chromium ions in orthodontic patients and their possible influence on hepatic enzymes: an in vivo study. J Ind Orthod Soc 48:518–524

    Article  Google Scholar 

  • Schäfer T, Böhler E, Ruhdorfer S, Weigl L, Wessner D, Filipiak B, Wichmann HE Ring., J(2001) Epidemiology of contact allergy in adults. Allergy. 56:1192–1196

    Article  Google Scholar 

  • Schmalz G, Arenholt-Bindslev D (2009) Biocompatibility of dental materials; Springer-Verlag: Berlin-Heidelberg, Germany, pp. 99–137

  • Sidhu SK, Nicholson JW (2016) A review of glass-ionomer cements for clinical dentistry. J Funct Biomater 7:2–15

    Article  CAS  Google Scholar 

  • Spalj S, Mlacovic Zrinski M, Tudor Spalj V, Ivankovic, Buljan Z (2012) In-vitro assessment of oxidative stress generated by orthodontic archwires. Am J Orthod Dentofac Orthop 141:583–589

    Article  Google Scholar 

  • Stojsavljević A, Trifković J, Rasić-Milutinović Z, Jovanović D, Bogdanović G, Mutić J, Manojlović D (2018) Determination of toxic and essential trace elements in serum of healthy and hypothyroid respondents by ICP-MS: a chemometric approach for discrimination of hypothyroidism. J Trace Elem Med Biol 48:134–140

    Article  CAS  Google Scholar 

  • Talic NF, Alnahwi HH, Al-Faraj AS (2013) Nickel and chromium levels in the saliva of a Saudi sample treated with fixed orthodontic appliances. Saudi Dental J 25:129–133

    Article  Google Scholar 

  • Thomas P, Weik T, Roider G, Summer B, Thomsen M (2016) Influence of surface coating on metal ion release: evaluation in patients with metal allergy. Orthopedic. 39:24–30. https://doi.org/10.3928/01477447-20160509-08

    Article  Google Scholar 

  • Thyssen JP, Linneberg A, Menné T, Johansen JD (2007) The epidemiology of contact allergy in the general population prevalence and main findings. Contact Dermatitis 57:287–299

    Article  Google Scholar 

  • Wendl B, Wiltsche H, Lankmayr E, Winsauer H, Walter A, Muchitsch A (2017) Metal release profiles of orthodontic bands, brackets, and wires: an in vitro study. J Orofac Orthop 78:494–503

    Article  CAS  Google Scholar 

Download references

Acknowledgments

The authors would like to gratefully acknowledge all of our colleagues at the Density Research Center (DRC) of Birjand University of Medical Sciences who contributed greatly to this study. Moreover, the authors thank Mr. Alireza Amirabadi and Mr. Ali Farahi for their technical assistance.

Conflict of interest

The authors declare that they have no competing interests.

Funding

This study was supported by the Birjand University of Medical Sciences (Grant number BUMS.1398.109).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Borhan Mansouri.

Ethics declarations

The present study was approved by the Ethics Committee of Birjand University of Medical Sciences (IR.BUMS.REC.1398.109).

Additional information

Responsible editor: Philippe Garrigues

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

ESM 1

(DOC 98 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Moghadam, M.G., Hoshyar, R., Mikulewicz, M. et al. Biomonitorization of metal ions in the serum of Iranian patients treated with fixed orthodontic appliances in comparison with controls in eastern Iran. Environ Sci Pollut Res 26, 33373–33386 (2019). https://doi.org/10.1007/s11356-019-06414-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11356-019-06414-1

Keywords

Navigation