Indoor and outdoor concentrations of BTEX and formaldehyde in Tehran, Iran: effects of building characteristics and health risk assessment

  • Research Article
  • Published:
Environmental Science and Pollution Research Aims and scope Submit manuscript

A Correction to this article was published on 03 August 2018

This article has been updated

Abstract

BTEX (benzene, toluene, ethylbenzene, xylene) and formaldehyde are toxic compounds that can induce adverse health effect in humans. This study measured in-home and ambient concentrations of BTEX and formaldehyde across Tehran, Iran. These pollutants were sampled from the indoor and adjacent outdoor air of 45 houses (9 in each city zone) during the winter of 2015. Sampling was repeated three times for each house. The analyses were performed according to NIOSH procedures. The effect of flooring material, wall covering, ventilation system, heating system, height above ground, presence of attached garages, and distance from highways was evaluated. In addition, carcinogenic and non-carcinogenic risks of these compounds were assessed. The average indoor concentrations of benzene, toluene, ethylbenzene, xylene, and formaldehyde were 53.2, 21.5, 14.4, 21.1, and 17.9 μg/m3, respectively. The average outdoor concentrations of benzene, toluene, ethylbenzene, xylene, and formaldehyde were 43.5, 26.2, 10.0, 19.1, and 6.9 μg/m3, respectively. Separate regression models showed that wall coating, ventilation system, heating system, flat level, and distance from highways explained 29, 60, 16, 60, and 59% of the BTEX concentrations, respectively. Houses with oil painted walls and parquet flooring had higher concentrations of BTEX and formaldehyde, respectively. The health risk assessment found that the carcinogenic risks of benzene and formaldehyde exceeded 1 × 10−4 and represent a definite risk. New buildings can be designed based on the results of this study to use better materials and optimum building designs to reduce exposure to these toxic air pollutants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

Change history

  • 03 August 2018

    The original publication of this paper contains a mistake. The correct name and affiliation of the 3rd Author is presented in this paper.

References

  • Ahadi SR, Mohsen, Tadari M, Torbatian S (2016) Annual report on the ambient air quality of Tehran, 2015–2016 (1394), Tehran air quality control company (TAQCC). Tehran, Iran

    Google Scholar 

  • Amini H, Hosseini V, Schindler C, Hassankhany H, Yunesian M, Henderson SB, Künzli N (2017) Spatiotemporal description of BTEX volatile organic compounds in a Middle Eastern megacity: Tehran Study of Exposure Prediction for Environmental Health Research (Tehran SEPEHR). Environ Pollut 226:219–229

    Article  CAS  Google Scholar 

  • Atlas of Tehran Metropolis (2006) Population density of Tehran (Available at: http://atlas.tehran.ir/Default.aspx?tabid=269) Tehran

  • Baker EL, Smith TJ, Landrigan PJ (1985) The neurotoxicity of industrial solvents: a review of the literature. Am J Ind Med 8:207–217

    Article  CAS  Google Scholar 

  • Bertaud A (2003) Tehran spatial structure: constraints and opportunities for future development. Ministry of Housing and Urban Development, Tehran

    Google Scholar 

  • Bourdin D, Mocho P, Desauziers V, Plaisance H (2014) Formaldehyde emission behavior of building materials: on-site measurements and modeling approach to predict indoor air pollution. J Hazard Mater 280:164–173

    Article  CAS  Google Scholar 

  • Canha N, Lage J, Candeias S, Alves C, Almeida SM (2017) Indoor air quality during sleep under different ventilation patterns. Atmos Pollut Res 8:1132–1142

    Article  Google Scholar 

  • Colborn T, Schultz K, Herrick L, Kwiatkowski C (2014) An exploratory study of air quality near natural gas operations. Hum Ecol Risk Assess Int J 20:86–105

    Article  CAS  Google Scholar 

  • Crable JV, Taylor DG (1977) NIOSH manual of analytical methods, 2. US Dept. of Health, Education, and Welfare, Public Health Service, Center for Disease Control, National Institute for Occupational Safety and Health

  • Dehghani MH, Salari M, Naddafi K, Nazmara S, Ahmadi E, Kumar P (2017) Evaluation of formaldehyde concentration in the ambient air of a most populated Iranian city, Tehran. Air Quality, Atmosphere & Health, 1–10

  • Demirel G, Özden Ö, Döğeroğlu T, Gaga EO (2014) Personal exposure of primary school children to BTEX, NO 2 and ozone in Eskişehir, Turkey: relationship with indoor/outdoor concentrations and risk assessment. Sci Total Environ 473:537–548

    Article  CAS  Google Scholar 

  • Department of Environment (DOE) 2017 Actions and programs of the National Center for Air and Climate Change [in Persian], Department of Environment (DOE)

  • Derbez M, Berthineau B, Cochet V, Pignon C, Ribéron J, Wyart G, Mandin C, Kirchner S (2014) A 3-year follow-up of indoor air quality and comfort in two energy-efficient houses. Build Environ 82:288–299

    Article  Google Scholar 

  • Du L, Prasauskas T, Leivo V, Turunen M, Pekkonen M, Kiviste M, Aaltonen A, Martuzevicius D, Haverinen-Shaughnessy U (2015) Assessment of indoor environmental quality in existing multi-family buildings in North–East Europe. Environ Int 79:74–84

    Article  CAS  Google Scholar 

  • Durmusoglu E, Taspinar F, Karademir A (2010) Health risk assessment of BTEX emissions in the landfill environment. J Hazard Mater 176:870–877

    Article  CAS  Google Scholar 

  • Eller PM, Cassinelli ME (1994): NIOSH manual of analytical methods, 94. Diane Publishing

  • EPA A 1989 Risk assessment guidance for superfund. Volume I: Human health evaluation manual (Part A), EPA/540/1–89/002

  • Esplugues A, Ballester F, Estarlich M, Llop S, Fuentes-Leonarte V, Mantilla E, Iñiguez C (2010) Indoor and outdoor air concentrations of BTEX and determinants in a cohort of one-year old children in Valencia, Spain. Sci Total Environ 409:63–69

    Article  CAS  Google Scholar 

  • European Commission (2005) The INDEX project: critical appraisal of the setting and implementation of indoor exposure limits in the EU, Joint Research Centre, Institute for Health and Consumer Protection. Ispra, Italy

    Google Scholar 

  • European Parliament and the Council (2008): Directive 2008/50/EC on ambient air quality and cleaner air for Europe

  • Giang NTH, Oanh NTK (2014) Roadside levels and traffic emission rates of PM2. 5 and BTEX in Ho Chi Minh City, Vietnam. Atmos Environ 94:806–816

    Article  CAS  Google Scholar 

  • Graham LA, Noseworthy L, Fugler D, O'Leary K, Karman D, Grande C (2004) Contribution of vehicle emissions from an attached garage to residential indoor air pollution levels. J Air Waste Manage Assoc 54:563–584

    Article  CAS  Google Scholar 

  • Hadei M, Hopke PK, Nazari SSH, Yarahmadi M, Shahsavani A, Alipour MR (2017) Estimation of mortality and hospital admissions attributed to criteria air pollutants in Tehran Metropolis, Iran (2013–2016). Aerosol Air Qual Res 17:2474–2481

    Article  CAS  Google Scholar 

  • Hazrati S, Rostami R, Farjaminezhad M, Fazlzadeh M (2016) Preliminary assessment of BTEX concentrations in indoor air of residential buildings and atmospheric ambient air in Ardabil, Iran. Atmos Environ 132:91–97

    Article  CAS  Google Scholar 

  • Hesterberg TW, Lapin CA, Bunn WB (2008) A comparison of emissions from vehicles fueled with diesel or compressed natural gas. Environ Sci Technol 42:6437–6445

    Article  CAS  Google Scholar 

  • Hopke PK, Hashemi Nazari SS, Hadei M, Yarahmadi M, Kermani M, Yarahmadi E, Shahsavani A (2018): Spatial and temporal trends of short-term health impacts of PM2.5 in Iranian Cities: a modelling approach (2013-2016). Aerosol Air Qual. Res

  • Huang L, Mo J, Sundell J, Fan Z, Zhang Y (2013) Health risk assessment of inhalation exposure to formaldehyde and benzene in newly remodeled buildings, Beijing. PLoS One 8:e79553

    Article  CAS  Google Scholar 

  • Hulin M, Caillaud D, Annesi-Maesano I (2010) Indoor air pollution and childhood asthma: variations between urban and rural areas. Indoor Air 20:502–514

    Article  CAS  Google Scholar 

  • Hun DE, Siegel JA, Morandi MT, Stock TH, Corsi RL (2009) Cancer risk disparities between Hispanic and non-Hispanic white populations: the role of exposure to indoor air pollution. Environ Health Perspect 117:1925–1931

    Article  CAS  Google Scholar 

  • Hun DE, Corsi RL, Morandi MT, Siegel JA (2010) Formaldehyde in residences: long-term indoor concentrations and influencing factors. Indoor Air 20:196–203

    Article  CAS  Google Scholar 

  • Keyhani A, Ghasemi-Varnamkhasti M, Khanali M, Abbaszadeh R (2010) An assessment of wind energy potential as a power generation source in the capital of Iran, Tehran. Energy 35:188–201

    Article  Google Scholar 

  • Kim E-H, Kim S, Lee JH, Kim J, Han Y, Kim Y-M, Kim G-B, Jung K, Cheong H-K, Ahn K (2015) Indoor air pollution aggravates symptoms of atopic dermatitis in children. PLoS One 10:e0119501

    Article  CAS  Google Scholar 

  • Kim H, Taguchi S, Tanabe S (2005) Measurement and evaluation of indoor air quality by passive method in Korean houses. Proceedings of Indoor Air Conference, Beijing, China, pp 712–717

    Google Scholar 

  • Kim S-S, Kang D-H, Choi D-H, Yeo M-S, Kim K-W (2008) Comparison of strategies to improve indoor air quality at the pre-occupancy stage in new apartment buildings. Build Environ 43:320–328

    Article  Google Scholar 

  • Knöppel H, Wolkoff P (2013): Chemical, microbiological, health and comfort aspects of indoor air quality-state of the art in SBS, 4. Springer Science & Business Media

  • Kumar A, Singh BP, Punia M, Singh D, Kumar K, Jain V (2014) Assessment of indoor air concentrations of VOCs and their associated health risks in the library of Jawaharlal Nehru University, New Delhi. Environ Sci Pollut Res 21:2240–2248

    Article  CAS  Google Scholar 

  • LaGrega MD, Buckingham PL, Evans JC (2010) Hazardous waste management. Waveland Press

  • Licen S, Tolloi A, Briguglio S, Piazzalunga A, Adami G, Barbieri P (2016) Small scale spatial gradients of outdoor and indoor benzene in proximity of an integrated steel plant. Sci Total Environ 553:524–531

    Article  CAS  Google Scholar 

  • Liu J, Zhang G, Li Z, Hao J, Lin J, Liu Y (2005) Indoor environmental pollution investigation and controlling measures of house. Indoor Air Supplement 15:44

    Google Scholar 

  • Liu J, Guo Y, Pan X (2008) Study of the current status and factors that influence indoor air pollution in 138 houses in the urban area in Xi'an. Ann N Y Acad Sci 1140:246–255

    Article  CAS  Google Scholar 

  • Liu K, Zhang C, Cheng Y, Liu C, Zhang H, Zhang G, Sun X, Mu Y (2015) Serious BTEX pollution in rural area of the North China Plain during winter season. J Environ Sci 30:186–190

    Article  Google Scholar 

  • Llop S, Ballester F, Aguilera I, Estarlich M, Fernandez-Patier R, Sunyer J, Esplugues A, Iniguez C (2010) Outdoor, indoor and personal distribution of BTEX in pregnant women from two areas in Spain—preliminary results from the INMA project. Atmos Pollut Res 1:147–154

    Article  CAS  Google Scholar 

  • Lotfi S, Koohsari MJ (2009) Measuring objective accessibility to neighborhood facilities in the city (a case study: zone 6 in Tehran, Iran). Cities 26:133–140

    Article  Google Scholar 

  • Martins EM, Quiterio SL, Corrêa SM, Fortes JDN, Monteiro M, Prestes B (2014) BTEX inside a spinning classroom. Cadernos Saúde Coletiva 22:218–220

    Article  Google Scholar 

  • Masih A, Lall AS, Taneja A, Singhvi R (2017) Exposure profiles, seasonal variation and health risk assessment of BTEX in indoor air of homes at different microenvironments of a terai province of northern India. Chemosphere 176:8–17

    Article  CAS  Google Scholar 

  • MohseniBandpi A, Eslami A, Shahsavani A, Khodagholi F, Alinejad A (2017) Physicochemical characterization of ambient PM 2.5 in Tehran air and its potential cytotoxicity in human lung epithelial cells (A549). Sci Total Environ 593-594:182–190

    Article  CAS  Google Scholar 

  • National Research Council (2011) Review of the environmental protection agency’s draft IRIS assessment of formaldehyde. National Academies Press

  • Pellizzari ED, Perritt K, Hartwell T, Michael L, Sparacino C 1987: Total exposure assessment methodology (TEAM) study: Elizabeth and Bayonne, New Jersey, Devils Lake, North Dakota and Greensboro, North Carolina. Volume 2, parts 1 and 2. Final report, Research Triangle Inst., Research Triangle Park, NC (USA)

  • Perez-Rial D, Lopez-Mahia P, Muniategui-Lorenzo S, Prada-Rodriguez D (2009) Temporal distribution, behaviour and reactivities of BTEX compounds in a suburban Atlantic area during a year. J Environ Monit 11:1216–1225

    Article  CAS  Google Scholar 

  • Prasad R, Uma R, Kansal A, Gupta S, Kumar P, Saksena S (2002) Indoor air quality in an air-conditioned building in New Delhi and its relationship to ambient air quality. Indoor Built Environ 11:334–339

    Article  CAS  Google Scholar 

  • Ramírez N, Cuadras A, Rovira E, Borrull F, Marcé RM (2012) Chronic risk assessment of exposure to volatile organic compounds in the atmosphere near the largest Mediterranean industrial site. Environ Int 39:200–209

    Article  CAS  Google Scholar 

  • Robson MG, Toscano WA (2007): Risk assessment for environmental health, 2. John Wiley & Sons

  • Sakai K, Norbäck D, Mi Y, Shibata E, Kamijima M, Yamada T, Takeuchi Y (2004) A comparison of indoor air pollutants in Japan and Sweden: formaldehyde, nitrogen dioxide, and chlorinated volatile organic compounds. Environ Res 94:75–85

    Article  CAS  Google Scholar 

  • Salthammer T, Mentese S, Marutzky R (2010) Formaldehyde in the indoor environment. Chem Rev 110:2536–2572

    Article  CAS  Google Scholar 

  • Salthammer T (2013) Formaldehyde in the ambient atmosphere: from an indoor pollutant to an outdoor pollutant? Angew Chem Int Ed 52:3320–3327

    Article  CAS  Google Scholar 

  • Sarkhosh M, Mahvi A, Zare M, Alavi J, Mohseni M (2013a) Assessment of volatile organic compound (voc) in Tehran air pollution in 2010-2011. Journal of Rafsanjan University of Medical Sciences 12:271–278

  • Sarkhosh M, Mahvi AH, Yunesian M, Nabizadeh R, Borji S.H, Bajgirani A G (2013b) Source apportionment of volatile organic compounds in Tehran, Iran. Bull Environ Contam Toxicol 90(4):440–445

  • Shahbazi HB, Mahdi A, HH Vahid 2015 Tehran’s air pollution emission inventory for the year 2013- Volume II: mobile sources [In Persian]. QM/94/04/03/(U)/02, Tehran Air Quality Control Company, Tehran, Iran

  • Smith MT, Guyton KZ, Gibbons CF, Fritz JM, Portier CJ, Rusyn I, DeMarini DM, Caldwell JC, Kavlock RJ, Lambert PF (2016) Key characteristics of carcinogens as a basis for organizing data on mechanisms of carcinogenesis. Environ Health Perspect 124:713

    Article  CAS  Google Scholar 

  • Tiwary A, Colls J (2009) Air pollution: measurement, modelling and mitigation. Taylor & Francis

  • United States Environmental Protection Agency 2007: Voluntary Children’s Chemical Evaluation Program. VCCEP Tier 1 Assessment for Ethylbenzene (CAS No. 100–41-4), Washington D.C., Available at: http://www.epa.gov/triexplorer/chemical.htm

  • Wallace L (1990) Major sources of exposure to benzene and other volatile organic chemicals. Risk Anal 10:59–64

    Article  Google Scholar 

  • Wang Z, Cao J, Cai H, Chen L (2009) Study on indoor air quality characteristics and air contaminants control strategies in urban residential environment in Xi’an, Bioinformatics and Biomedical Engineering, 2009. ICBBE 2009. 3rd International Conference on. IEEE, pp. 1–6

  • Wong NH, Huang B (2004) Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore. Build Environ 39:1115–1123

    Article  Google Scholar 

  • Wong O (1995) Risk of acute myeloid leukaemia and multiple myeloma in workers exposed to benzene. Occup Environ Med 52:380–384

    Article  CAS  Google Scholar 

  • World Health Organization (2010) WHO guidelines for indoor air quality: selected pollutants. WHO

  • Yarahmadi M, Hadei M, Nazari SSH, Conti GO, Alipour MR, Ferrante M, Shahsavani A (2018) Mortality assessment attributed to long-term exposure to fine particles in ambient air of the megacity of Tehran. Environmental Science and Pollution Research, Iran

    Google Scholar 

  • Zhu S, Cai W, Yoshino H, Yanagi U, Hasegawa K, Kagi N, Chen M (2015) Primary pollutants in schoolchildren’s homes in Wuhan. China Build Environ 93:41–53

    Article  Google Scholar 

Download references

Funding

This study was funded by the Shahid Beheshti University of Medical Sciences (grant number #7653) and Tehran University of Medical Sciences (grant number # 24509).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Abbas Shahsavani.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Additional information

Responsible editor: Constantini Samara

The original publication of this paper contains a mistake.

The correct name and affiliation of the 3rd Author is presented in this paper.

The original version of this article was revised.

Electronic supplementary material

ESM 1

(DOCX 338 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hadei, M., Hopke, P.K., Rafiee, M. et al. Indoor and outdoor concentrations of BTEX and formaldehyde in Tehran, Iran: effects of building characteristics and health risk assessment. Environ Sci Pollut Res 25, 27423–27437 (2018). https://doi.org/10.1007/s11356-018-2794-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11356-018-2794-4

Keywords

Navigation