Abstract
Telemedicine health created from the combination of IT and BT technologies has received increased attention for improved quality of life in medically vulnerable regions. As the health care paradigm shifts to preventive management in diagnosis and treatment, the importance of prevention of chronic diseases such as obesity is growing. In this paper, we proposed a picocell-based telemedicine health service for the human UX/UI based on a BT-IT fusion technology considering user convenience. The proposed medical service is a BT-IT fusion technology based on the telemedicine health service that can overcome the spatial limitations of hospital-oriented medical services in order to improve user convenience while naturally combining life and medical service spaces. Human UX/UI technology, which is based on sensor network and biomedical technology, requires next generation wireless communication between devices that connects the inside of the human body with the outside. A heterogeneous network is composed within a single domain, as the frequency bandwidth used by the medical device in the ISM bandwidth is different. If a wireless device and low output ISM device spatially access a heterogeneous network, then an interference problem will occur between the small cells. Additionally, there can be interference as the traffic is off-loaded from the base station at the grouped region of a hotspot. A fatal problem may occur due to an information error of the patient due to interference. To solve the interference problem generated by the telemedicine health platform, the performance of the picocell-based telemedicine health service can be improved by applying scheduling using ABS(Almost Blank Subframe) in the time domain. Therefore, the human UX/UI and the provided guidelines can quickly provide patient information, thereby increasing safety of patients.
Similar content being viewed by others
Notes
Fraunhofer, http://www.fraunhofer.de/
Noom weight, http://www.noom.com
References
Ahmed A, Ehsan N, Mirza E, Awan SA (2010) “Information technology: a means of quality in healthcare”, In Proc. of the 3rd IEEE International Conference on Computer Science and Information Technology, Vol. 9, pp 26–30
Baek SJ, Han JS, Chung KY (2013) Dynamic reconfiguration based on goal-scenario by adaptation strategy. Wirel Pers Commun 73(2):309–318
Berndt RD, Takenga MC, Kuehn S, Preik P (2011) “A Scalable and Secure Telematics Platform for the Hosting of Telemedical Applications : Case Study of a Stress and Fitness Monitoring”, In Proc. of the 13th IEEE International e-Health Networking Applications and Services , Vol. 1, pp 118–121
Cheng SH, Huang CY (2013) Coloring-based inter-WBAN scheduling for mobile wireless body area networks. IEEE Trans Parallel Distrib Syst 24(2):250–259
COMMWELL, http://www.commwell.biz/
Costin H, Rotariu C, Morancea O, Cehan V, Felea V, Alexa I (2008) “Complex Telemonitoring of Patients and Elderly People for Telemedical and Homecare services”, In Proc. of the 1st WSEAS international conference on Biomedical electronics and biomedical informatics, Vol. 1, pp 183–187
Devaul R, Sung M, Gips J (2003) “MIThril 2003: applications and architecture”, In Proc. of the 7th IEEE International Symposium on Wearable Computers, Vol. 1, pp 4
EU Safe21, http://ec.europa.eu/
Han DS, Lee MK, Park SJ (2010) THE-MUSS: mobile u-health service system. Biomedicine 97(2):178–188
Hu JS, Jiang C (2012) “A proposal for construction of telemedicine information platform and extension of health care service”, In Proc. of the 14th International e-Health Networking, Applications and Services, Vol. 1, pp 534–537
JK, Jeong S, Jung EY, Park DK (2009) “Trend of wireless u-health”, In Proc. of the 9th International Conference on Communications and Information Technologies, Vol. 1, pp 829–833
Jokic S, Krco S, Sakac D, Jokic I (2012) “Autonomic Telemedical Application for Android based Mobile Devices”, In Proc. of the 11th Symposium on Neural Network Applications in Electrical Engineering, Vol. 1, pp 231–234
Kamel MI, Elsayed KM (2012) “Performance evaluation of a coordinated time-domain eICIC framework based on ABSF in heterogeneous LTE-advanced networks”, In Proc. of IEEE Global Communications Conference, Vol. 1, pp 5326–5331
Kang SK, Chung KY, Ryu JK, Rim KW, Lee JH (2013) Bio-interactive healthcare service system using lifelog based context computing. Wirel Pers Commun 73(2):341–351
Kang SW, Park HI, Park KH (2013) Trends of human body communications. Electron Telecommun Trends 28(2):70–76
Karim S, Bajwa IS (2011) “Clinical decision support system based virtual telemedicine”, In Proc. of International Conference on Intelligent Human-Machine Systems and Cybernetics, Vol. 1, pp 16–21
Khan P, Ullah N, Ullah S, Kwak KS (2011) Seamless interworking architecture for WBAN in heterogeneous wireless networks with QoS guarantees. J Med Syst 35(5):1313–1321
Khan JY, Yuce M, Bulger G, Harding B (2012) Wireless Body Area Network (WBAN) design techniques and performance evaluation. J Med Syst 36(3):1441–1457
Kim SH, Chung KY (2013) Medical information service system based on human 3D anatomical model. Multimedia Tools Appl. doi:10.1007/s11042-013-1584-8
Kim JY, Chung KY, Jung JJ (2014) Single tag sharing scheme for multiple-object RFID applications. Multimedia Tools Appl 68(2):465–477
Kim JK, Lee D, Chung KY (2012) Ontology driven interactive healthcare with wearable sensors. Multimedia Tools Appl. doi:10.1007/s11042-012-1195-9
Kukawka B, Wilk S (2012) “Indexing and Retrieval of Medical Resources for a Telemedical Platform”, In Proc. of the Third international conference on Information Technologies in Biomedicine, Vol. 1, pp 603–614
Lee JC, Yoo SM (2012) Intelligent cell selection satisfying user requirements for inter-system handover in heterogeneous networks. Comput Commun 35(17):2106–2114
Lopez G, Custodio V, Moreno J (2010) Lobin: e-textile and wirelesssensor- network-based platform for healthcare monitoring in future hospital environments. IEEE Trans Inf Technol Biomed 14(6):1446–1458
Lu N, Zhu X, Jiang Z, Lu X (2013) “Performance of LTE-advanced macro-pico heterogeneous networks”, In Proc. of the IEEE Wireless Communications and Networking Conference, Vol. 1, pp 545–550
Matsushita Electric industrial, http://panasonic.jp/
Mutafungwa E, Zheng Z, Hamalainen J, Husso M, Korhonen T (2010) “Exploiting femtocellular networks for emergency telemedicine applications in indoor environments”, In Proc. of the 12th IEEE International Conference on e-Health Networking Applications and Services, Vol. 1, pp 283–289
Oh JY, Kim JK, Lee HS, Choi SS (2010) Phase rotation shift keying for low power and high performance WBAN in-body systems”, In Proc. of the International Conference on Information and Communication Technology Convergence (ICTC), Vol. 1, pp 28–32
Paolo D, Marc PC, Jaume NG, Josep MB (2010) A reconfigurable test platform to experiment with wireless heterogeneous networks in a laboratory. Int J Commun Netw Distrib Syst 5(1/2):46–66
Park CY, Lim JH, Park S (2011) “ISO/IEEE 11073 PHD Standardization of Legacy Healthcare Devices for Home Healthcare Services”, In Proc. of the IEEE International Conference on Consumer Electronics, Vol. 1, pp 547–548
Qu H, Cheng J, Cheng Q, Wang LY (2009) “WiFi-based telemedicine system: signal accuracy and security”, In Proc. of the International Conference on Computational Science and Engineering, Vol. 2, pp 1081–1085
Rho MJ, Jang KS, Chung KY, Choi IY (2013) Comparison of Knowledge, Attitudes, and Trust for the Use of Personal Health Information in Clinical Research. Multimedia Tools Appl. doi:10.1007/s11042-013-1772-6
Soh YS, Quek TQS, Kountouris M, Shin HD (2013) Energy efficient heterogeneous cellular networks. IEEE J Sel Areas Commun 31(5):840–850
Sohn MS, Hahn DW, Lee JW (2006) “The strategy development of u-health service”, In Proc. of PICMET Technology Management for the Global Future, Vol. 5, pp 1931–1934
Taha M (2009) “Towards comprehensive RRM frameworks for heterogeneous wireless networks”, In Proc. of the 2009 conference on Information Science, Technology and Applications, Vol. 1, pp 1–7
Vleeschauwer B, Turck F, Dhoedt B, Demeester P (2008) “End-to-end QoE optimization through overlay network deployment”, In Proc. of International Conference on Information Networking, Vol. 1, pp 1–5
Xiao Y, Takahashi D, Liu J, Deng H, Zhang J (2011) Wireless telemedicine and m-health: technologies, applications and research issues. Int J Sens Networks 10(4):202–236
Yen YS, Chiang WC, Wang HY, Shiah CY (2011) “WiMAX Network for Health Care Telemonitoring Service”, In Proc. of the 2011 International Conference on Information Science and Applications, Vol. 1, pp 1–7
Zheng JW, Zhang ZB, Wu TH, Zhang Y (2007) A wearable mobihealth care system supporting real-time diagnosis and alarm. Med Biol Eng Comput 45(9):877–885
Zois DS, Levorato M, Mitra U (2013) Energy-efficient, heterogeneous sensor selection for physical activity detection in wireless body area networks. IEEE Trans Signal Process 61(7):1581–1594
Acknowledgments
This research was supported by the R&D Program for Society of the National Research Foundation (NRF) funded by the Ministry of Science, ICT & Future Planning (No. 2013M3C8A2A02078523).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Park, R.C., Jung, H., Chung, K. et al. Picocell based telemedicine health service for human UX/UI. Multimed Tools Appl 74, 2519–2534 (2015). https://doi.org/10.1007/s11042-014-1964-8
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11042-014-1964-8