Skip to main content

Advertisement

Log in

A Method of Material Optimization of Cementless Stem Through Functionally Graded Material

  • Published:
International Journal of Mechanics and Materials in Design Aims and scope Submit manuscript

Abstract

Ideally, a bone implant should be such that it exhibits an identical response to loading as real bone and is also biocompatible with existing tissue. A stiff stem, which is usually made of titanium, shields the proximal bone from mechanical loading (stress shielding). On the other hand, decreasing the stem stiffness increases the proximal interface shear stress and the risk of proximal interface failure. Therefore the purpose of this study is to solve these conflicting requirements in order to have more uniform interface shear stress distribution and less stress shielding through the concept of functionally graded material (FGM). FGM is a kind of advanced composite materials, which changes its composition and structure gradually over one or two directions of its volume, resulting in corresponding changes in the properties of the material. This study is divided into two parts; in the first part, the finite element analysis and optimization technique are used to design the stem as one-dimensional FGM, while in the second part, the stem is designed as two-dimensional functionally graded material. The aim of both designs is to overcome the above mentioned problems. In the case of part one (one-dimensional FGM), the gradation of elastic modulus is changed along the vertical direction (model 1) and along the horizontal direction (model 2), in order to find the optimal gradation direction. It is found that the optimal design is to change the elastic modulus gradually from 110 GPa (Hydroxyapatite) at the top of the stem to 1GPa (Collagen) at the bottom (model 1). This optimal gradation decreases stress shielding by 83%, while reduces the maximum interface shear stress by 32% compared to homogenous titanium stem. However, in the second part (two-dimensional FGM, model 3) the materials of optimal design are found to be hydroxyapatite, Bioglass, and collagen. This design leads to the same stress shielding reduction as in model 1, while at the same time, the maximum interface shear stress is reduced by 45% and 63% compared to the optimal one-dimensional FGM design and homogenous titanium stem, respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • M. Akay N. Aslan (1996) ArticleTitleNumerical and experimental stress analysis of polymeric composite hip joint prosthesis Journal of Biomedical Materials Research 31 167–182 Occurrence Handle10.1002/(SICI)1097-4636(199606)31:2<167::AID-JBM3>3.0.CO;2-L Occurrence Handle8731205

    Article  PubMed  Google Scholar 

  • W. Cao L.L. Hench (1996) ArticleTitleBioactive materials Ceramics International 22 493–507 Occurrence Handle10.1016/0272-8842(95)00126-3

    Article  Google Scholar 

  • Gatti, A.M., Hench, L.L., Morari, E., Thompson, I., and Tanza, D., (1998). Bioceramics. in R.Z. LeGeros, J.P. LeGeros (Eds.) World Scientific, Singapore, Vol. 11. pp. 349–352.

  • S. Gross E.W. Abel (2001) ArticleTitleA finite element analysis of hollow stemmed hip prostheses as a means of reducing stress shielding of the femur Journal of Biomechanics 34 995–1003 Occurrence Handle10.1016/S0021-9290(01)00072-0 Occurrence Handle11448691

    Article  PubMed  Google Scholar 

  • H.S. Hedia (2000) ArticleTitleShape optimization to maximize crack initiation time Bio-Medical Materials and Engineering 11 293–300

    Google Scholar 

  • H.S. Hedia A.A.A. Abdel-Shafi N. Fouda (2000) ArticleTitleShape optimization of metal backing for cemented acetabular cup Bio-Medical Materials and Engineering 10 73–82 Occurrence Handle11086841

    PubMed  Google Scholar 

  • H.S. Hedia D.C. Barton J. Fisher (1997) ArticleTitleMaterial optimization of the femoral component of a hip prosthesis based on the fatigue notch factor approach Bio-Medical Materials and Engineering 7 83–98 Occurrence Handle9262822

    PubMed  Google Scholar 

  • H.S. Hedia D.C. Barton J. Fisher (1996a) ArticleTitleShape optimization of a Charnley prosthesis based on the fatigue notch factor Bio-Medical Materials and Engineering 6 199–217

    Google Scholar 

  • H.S. Hedia D.C. Barton J. Fisher T.T. Elmidany (1996b) ArticleTitleA method for shape optimization of a hip prosthesis to maximize the fatigue life of the cement Medical Engineering & Physics 18 IssueID8 647–654

    Google Scholar 

  • H.S. Hedia M. Nemat-Alla (2004) ArticleTitleDesign optimization of functionally graded dental implant Bio-Medical Materials and Engineering 14 IssueID2 133–143 Occurrence Handle15156104

    PubMed  Google Scholar 

  • R. Huiskes R. Boeklagen (1989) ArticleTitleMathematical shape optimization of hip prosthesis design Journal of Biomechanics 22 IssueID8/9 793–804 Occurrence Handle10.1016/0021-9290(89)90063-8 Occurrence Handle2613715

    Article  PubMed  Google Scholar 

  • Itoh, S., Kawauchi, T., Shinomiya, K., Koyama, Y., et al. (2000). Osteoconductive activity of a novel biomaterial, Hydroxyapatite/Collagen composite, 46th Annual Meeting, March 12–15. Orthopaedic Research Society, Orlando, Florida.

  • S. Itoh M. Kikuchi Y. Koyama K. Takakuda K. Shinomiya J. Tanaka (2002) ArticleTitleDevelopment of an artificial vertebral body using a novel biomaterial Hydroxyapatite/collagen composite, Biomaterials 23 3919–3926

    Google Scholar 

  • Jeffers, J.R.T. and Taylor, M., (2003). Mesh Considerations for Adaptive Finite Element Analyses of Cement Failure in Total Hip Replacement. Sonesta Beach Resort in Key Biscayne, Florida, Summer Bioengineering Conference, June 25–29.

  • J.R. Jones L.L. Hench (2001) ArticleTitleBiomedical materials for new millennium: perspective on the future Material Science and Technology 17 891–900

    Google Scholar 

  • H. Katoozian D.T. Davy A. Arshi U. Saadati (2001) ArticleTitleMaterial optimization of femoral component of total hip prosthesis using fiber reinforced polymeric composites Medical Engineering & Physics 23 503–509

    Google Scholar 

  • T. Kokubo H.M. Kim M. Kawashita (2003) ArticleTitleNovel bioactive materials with different mechanical properties Journal of Biomaterials 24 2161–2175 Occurrence Handle10.1016/S0142-9612(03)00044-9

    Article  Google Scholar 

  • Kuiper J.H., Huiskes R., (1992). Numerical optimization of hip-prosthetic stem material, Recent Advances in Computer Methods in Biomechanics & Biomedical Engineering. J. Mddleton, G.N. Pande, and K.R. Williams, pp. 76–84.

  • J.H. Kuiper R. Huiskes (1997) ArticleTitleMathematical optimization of elastic properties: Application to cementless hip stem design Journal of Biomechanical Engineering 119 166–174 Occurrence Handle9168392

    PubMed  Google Scholar 

  • R. Miyao A. Yokoyama F. Watari T. Kawasaki (2001) ArticleTitleProperties of Titanium/Hydroxyapatite functionally graded implants by spark plasma sintering The Journal of the Japanese Society for Dental Materials and Devices 20 IssueID6 344–355

    Google Scholar 

  • M. Nematt-Allah (2003) ArticleTitleReduction of thermal stresses by developing two-dimensional functionally graded materials International Journal of Solids and Structures 40 7339–7356 Occurrence Handle10.1016/j.ijsolstr.2003.08.017

    Article  Google Scholar 

  • W. Pompe M. Gelinsky I. Hofinger B.K. Nicolai (2001) ArticleTitleFunctional graded collagen-hydroxyapatite materials for bone replacement Ceramic Transactions 114 65–72

    Google Scholar 

  • R. Shirandami I.I. Esat (1990) ArticleTitleNew design of hip prosthesis using carbon fibre reinforced composite Journal of Biomedical Engineering 12 19–22 Occurrence Handle2296163

    PubMed  Google Scholar 

  • J.A. Simoes A.T. Marques G. Jeronimidis (2000) ArticleTitleDesign of a controlled-stiffness composite proximal femoral prosthesis Composite Science and Technology 60 559–567 Occurrence Handle10.1016/S0266-3538(99)00155-4

    Article  Google Scholar 

  • Thompson, I., Hench, L.N., (2000). Comprehensive composite materials Vol. 6: Design and applications, 6.39: Medical applications of composites, Elsevier Science Ltd., pp. 727–753.

  • F. Watari H. Kondo S. Matsuo R. Miyao et al. (2003) ArticleTitleDevelopment of functionally graded implant and dental post for bio-medical application Materials Science Forum 423–425 321–326

    Google Scholar 

  • H. Weinans D.R. Sumner R. Igloria R.N. Natarajan (2000) ArticleTitleSensetivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models Journal of Biomechanics 33 809–817 Occurrence Handle10.1016/S0021-9290(00)00036-1 Occurrence Handle10831755

    Article  PubMed  Google Scholar 

  • L.J. Zhang X.S. Feng H.G. Liu D.J. Qian L. Zhang X.L. Yu F.Z. Cui (2004) ArticleTitleHydroxyapatite/collagen composite materials formation in simulated body fluid environment Materials Letters 58 719–722 Occurrence Handle10.1016/j.matlet.2003.07.009

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H.S. Hedia.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hedia, H., Shabara, M., El-Midany, T. et al. A Method of Material Optimization of Cementless Stem Through Functionally Graded Material. Int J Mech Mater Des 1, 329–346 (2004). https://doi.org/10.1007/s10999-005-3307-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10999-005-3307-4

Keywords

Navigation