Abstract
In this paper rapid separation methods for strontium determination using molecular recognition technology products 3M Empore™ Sr disc, AnaLig® Sr-01 and extraction chromatography Sr® Resin were presented and statistical tested. The methods performance was investigated by analysis of NPL (High Alpha–Beta 2003) and (High Alpha–Beta 2005) intercomparison samples. The presented results were evaluated as correct for all experimental data. We used linear regression (with regression diagnostics), t test and the mean of variable using 90Sr with 3M Empore™ Sr disc, AnaLig® Sr-01 and Sr® Resin.
Similar content being viewed by others
References
Grahek Ž, Eškinja I, Košutić K, Štefica-Cerjan S (2000) Croat Chem Acta 73(3):795–807
Mitra (ed) (2003) Sample preparation techniques in analytical chemistry, vol 162. Wiley–Interscience, New Jersey, pp 79–112
Izatt SR, Bruening RL, Krakowiak KE, Izatt RM (2003) The selective separation of anions and cations in nuclear waste using commercially available molecular recognition technology products. In: Proc WM 03 Conf, Tuscon
Izatt RM, Bradshaw JS, Bruening RL (1996) Pure Appl Chem 68(6):1237–1241
Goken GL, Bruening RL, Krakowiak KE, Izatt RM (1999) Metal-ion separations using Superlig or Analig materials encased in empore cartriges and discs. ACS Symposium Series 716. American Chemical Society, p 251
3M Method summaries for strontium rad discs, technetium rad discs and cesium rad discs. 3M Company, St. Paul. www.3m.com/empore
Beals DM, Britt WG, Bibler JP, Brooks (1998) J Radioanal Nucl Chem 236:187
Scarpitta S, Odin-McCabe J, Gaschott R, Meier A, Klug E (1999) Health Phys 76:644
Seely DC (1999) RLS product development, presented at the 3M Rad Chem products workshop: analysis to remediation, Gaithersburg
Seely DC, Osterheim JA (1998) J Radioanal Nucl Chem 236:175–180
Fiskus SK, Riley RG, Thompson CJ (2000) J Radioanal Nucl Chem 245:261–272
Rapid Sampling Using 3M membrane technology, DOE/EM-0501, 2000. http://costperformance.org/monitoring/pdf/itsr1514.pdf
Ometáková J, Dulanská S, Mátel Ľ, Remenec B (2011) J Radioanal Nucl Chem 290(2):319–323
Meloun M, Militký J, Hill M, Brereton RG (2002) Problems in regression modeling and their solutions. Analyst 127:433–450
Meloun M, Militký J (2001) Detection of single influential points in regression model building (Tutorial). Anal Chim Acta 439:169–191
Meloun M, Militký J, Forina M (1994) Chemometrics for analytical chemistry, PC-aided regression and related methods, vol 2. Horwood, Chichester
Meloun M, Militký J (2006) Kompendium statistického zpracování dat, pp 609–629
Dulanská S, Meloun M, Mátel Ľ (2010) J Radioanal Nucl Chem 285(3):547–553
Dulanská S, Meloun M, Mátel Ľ (2009) J Radioanal Nucl Chem 280(3):519–531
IBC Advanced Technologies: AnaLig gel data sheet strontium column series SR-01. IBC Advanced Technologies, Inc
Dulanska S, Remenec B, Matel Ľ, Galanda D, Molnár A (2011) J Radioanal Nucl Chem 288:705–708
Eichrom Industries Inc. http://www.eichrom.com/products/info/sr_resin.cfm. Accessed 04 March 2012
Acknowledgments
This work was supported by the Slovak Research and Development Agency under the contract no.SK-CZ-0047-11.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Dulanská, S., Remenec, B., Galanda, D. et al. Statistical suitability testing of 3M Empore™ Sr disc and AnaLig® Sr-01 use for 90Sr determination. J Radioanal Nucl Chem 293, 965–971 (2012). https://doi.org/10.1007/s10967-012-1785-z
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-012-1785-z