Skip to main content
Log in

Energy resolution improvement of NaI(Tl) scintillation detectors by means of a timing discrimination method

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Gamma-ray energy spectrum of a 137Cs radioisotope was obtained by using a NaI(Tl) scintillation detector. Improvement of the energy resolution of the detector was aimed. To achieve this, constant fraction timing method was used. Energy resolution of the photopeak of the isotope was improved from 7.1 to 6.7% through the timing application.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. Knoll GF (2000) Radiation detection and measurements. Wiley, New York

    Google Scholar 

  2. Leo RW (1987) Techniques for nuclear and particle physics experiments. Springer, Berlin

    Book  Google Scholar 

  3. Tsoulfanidis N (1995) Measurements and detection radiation. Taylor & Francis, Washington, DC

    Google Scholar 

  4. Abuelhia E, Alzimami K, Alkhorayef M, Podolyak Z, Spyrou NM (2008) J Radioanal Nucl Chem 278:767–771

    Article  CAS  Google Scholar 

  5. Troyer GL, Keele BD, Tepper GC (2001) J Radioanal Nucl Chem 248:267–271

    Article  CAS  Google Scholar 

  6. Ohsaki T, Nagai Y, Igashira M, Shima T, Suzuki TS, Kikuchi T, Kobayashi T, Takaoka T, Kinoshita M, Nobuhara Y (1999) Nucl Instrum Methods A 425:302–319

    Article  CAS  Google Scholar 

  7. Lynch FJ (1966) IEEE Trans Nucl Sci 13:140–147

    Article  CAS  Google Scholar 

  8. Al-Azmi D (2008) Appl Radiat Isot 66:1108–1116

    Article  CAS  Google Scholar 

  9. http://www.matpack.de/Info/Nuclear/Nuclids/nuclids9.html. Accessed 13 Feb 2012

  10. Model 552 pulse shape analyzer/timing single channel analyzer catalogue. EG&G ORTEC Part Number 733460 Manual Revision D, USA

  11. Turner JE (2007) Atoms, radiation and radiation protection. Wiley, Weinheim

    Book  Google Scholar 

Download references

Acknowledgments

This work was supported by TUBITAK, the Scientific and Technical Research Council of Turkey under Projects No. TBAG-1683(197T087) and 111T571, and by EBILTEM, Center of Science and Technology, Ege University under Project No. 99 BIL 001.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to C. Celiktas.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Celiktas, C., Ermis, E.E. & Bayburt, M. Energy resolution improvement of NaI(Tl) scintillation detectors by means of a timing discrimination method. J Radioanal Nucl Chem 293, 377–382 (2012). https://doi.org/10.1007/s10967-012-1678-1

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-012-1678-1

Keywords

Navigation