Abstract
Characterization is a first step to site cleanup or decommissioning of a disused nuclear facility. Good knowledge of the inventory of nuclides present, both type and location, is important in the design of an effective plan of remediation. Several systems based on HPGe detectors have been developed, both commercially and at laboratories, and are already in use for this purpose. Their use is somewhat complicated by the need for cryogenic cooling of the HPGe detector. Handling of liquid nitrogen in field situations is always difficult. Recent developments in low-power electromechanical cooling for HPGe detectors have made possible the construction of low weight, portable HPGe spectrometers with sufficient efficiency to perform the needed measurements in reasonable count times, without the need for liquid nitrogen. A mobile system was modified to use a battery-powered, Sterling-engine cooler on a nominal 40% relative efficiency detector. This system was characterized for efficiency and uniformity of response. The baseline spectra were analyzed using the DOE EML 1-meter methods to obtain representative MDA values for several nuclides of interest and typical counting times.
Similar content being viewed by others
References
H. L. Beck et al., In Situ Ge(Li) and NaI(Tl) Gamma-Ray Spectrometry, U.S. Department of Energy, Environmental Measurements Laboratory, HASL-258, September 1972.
K. M. Miller, P. Shebell, Radioact. Radiochem., 11 (2000) 14.
R. Keyser, T. Twomey, D. Upp, Performance of Light-Weight, Battery-Operated, High Purity Germanium Detectors for Field Use, INMM 2003 Annual Meeting Proc., July 2003.
IEEE 325-2006, IEEE Standard Test Procedures for Germanium Gamma-Ray Detectors Used in Analog and Digital Signal Processing Systems, IEEE Standards Association, 445 Hoes Lane, Piscataway, New Jersey 08855-1331.
ANSI N42.34, American National Standard, Performance Criteria for Hand-held Instruments for the Detection and Identification of Radionuclides, American National Standards Institute, 2003.
NuReg 4.16, Regulatory Guide 4.16, U.S. Nuclear Regulatory Commission, Appendix A, December 1985.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Keyser, R.M., Hagenauer, R.C. Performance of a portable, electromechanically-cooled HPGe detector for site characterization. J Radioanal Nucl Chem 277, 149–153 (2008). https://doi.org/10.1007/s10967-008-0723-6
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-008-0723-6