Abstract

Neutral beam injection (NBI) is recognized as one of the most effective means of plasma heating. A virtual instrument (VI) has been designed to provide electrical parameter measurement for the ion source of EAST-NBI. The VI is written using the National Instruments LabVIEW graphical programming language. All data acquisition (DAQ) is accomplished using ADLINK DAQ hardware interface and Task-oriented DAQ Driver. The VI can measure filament voltage, filament current, arc voltage, arc current and accelerating voltage etc. The data obtained from the VI are feedback of the ion source operation state and helpful to direct the operation parameter optimization of the ion source.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Y.X. Wan, J.G. Li, P.D. Weng, First engineering commissioning of EAST tokamak. Plasma Sci. Technol 8, 253 (2006)

    Article  ADS  Google Scholar 

  2. T. Itoh, N. Akino, N. Ebisawa, L. Grisham, A. Honda, L.Q. Hu, M. Kawai, M. Kazawa, M. Kuriyama, M. Kusaka, K. Mogaki, T. Nishitani, T. Ohga, Y. Okumura, H. Oohara, K. Ooshima, F. Satoh, H. Seki, Y. Tanai, R. Toyokawa, K. Usui, K. Watanabe, M. Yamaguti, H. Yamazaki, T. Yamazaki, Beam performance of negative-ion based NBI system for JT-60. Fusion Eng. Design 51–2, 1039 (2000)

    Article  Google Scholar 

  3. D. Ciric, D.P.D. Brown, C.D. Challis, B. Chuilon, S.J. Cox, B. Crowley, I.E. Day, D.C. Edwards, G. Evison, L.J. Hackett, S. Hotchin, Z. Hudson, I. Jenkins, T.T.C. Jones, R. King, M. Kovari, D. Martin, J. Milnes, A. Parkin, A.L. Puma, M. Shannon, A. Stevens, D. Stork, E. Surrey, C. Waldon, R. Warren, D. Wilson, D. Young, I.D. Young, Overview of the JET neutral beam enhancement project. Fusion Eng. Design 82, 610 (2007)

    Google Scholar 

  4. C.D. Hu, Conceptual design of neutral beam injection system for EAST. Plasma Sci. Technol 14, 567 (2012)

    Article  ADS  Google Scholar 

  5. Y.J. Xu, C.D. Hu, S. Liu, Y.H. Xie, L.Z. Liang, C.C. Jiang, Preliminary experimental study of ion beam extraction of EAST neutral beam injector. Chin. Phys. Lett. 29, 035201 (2012)

    Article  ADS  Google Scholar 

  6. C.D. Hu, Preliminary results of ion beam extraction tests on EAST neutral beam injector. Plasma Sci. Technol 14, 871 (2012)

    Article  ADS  Google Scholar 

  7. C.D. Hu, Y.H. Xie, The development of a megawatt-level high current ion source. Plasma Sci. Technol 14, 75 (2012)

    Article  ADS  Google Scholar 

  8. C.D. Hu, Achievement of 100 s long pulse neutral beam extraction in EAS T neutral beam injector. Plasma Sci. Technol 15, 201 (2013)

    Article  ADS  Google Scholar 

Download references

Acknowledgments

This work has been supported by the National Natural Science Foundation of China (Grant No. 11075183).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yongjian Xu.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tian, Z., Hu, C., Liu, S. et al. Electrical Parameter Measurement System of the Ion Source for EAST Neutral Beam Injector. J Fusion Energ 33, 145–148 (2014). https://doi.org/10.1007/s10894-013-9651-8

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10894-013-9651-8

Keywords

Navigation