Abstract
A growing number of surface treated titanium implants are routinely used in dental and orthopaedic surgery, with a view to enhancing integration capacity with osseous tissue. This study examines the use of bioactive glass 45S5 as an alternative abrasive and osteoproductive surface modification material. Abrasive blasting of commercially pure titanium with bioactive glass 45S5 produced an irregular finish with a surface roughness average (Sa) of 1.1 μm as determined by white light interferometry, backscattered and secondary electron microscopy. The roughness attained compares favourably with currently used implant designs. Further, Energy Dispersive X-ray Analysis (EDXA) and backscattered electron microscopy demonstrated that bioactive glass was distributed across the titanium surface and retained within fissures and roughened surface features. Being an osteoproductive material, this is advantageous as it is expected that the modified metallic surfaces will acquire osteopromotive properties, and thus be of benefit to the process of implantation in osseous tissue.
Similar content being viewed by others
References
M. LONG and H. J. RACK, Biomaterials 19 (1998) 1621
P.I. BRANEMARK, J. Prosthet. Dent. 50 (1983) 399
C. SCHMIDT, D. KASPAR, M. R. SARKAR, L. E. CLAES and A. A. IGNATUIS, J. Biomed. Mater. Res. 63 (2002) 252
A. CITEAU, J. GUICHEUX, C. VINATIER, P. LAYROLLE, T. P. NGUYEN, P. PILET and G. DALCUSI, Biomaterials 26 (2005) 157
M. AHMAD, D. GAWRONSKI, J. BLUM, J. GOLDBERG and G. GRONOWICZ, J. Biomed. Mater. Res. 46 (1999) 121
R. CASTELLANI, A. DE RUIJTER, H. RENGGLI and J. JANSEN, Clin. Oral. Implants Res. 10 (1999) 369
D.D. DELIGIANNI, N. KATSALA, S. LADAS, D. SOTIROPOULU, J. AMEDEE and Y. F. MISSIRLIS, Biomaterials 22 (2001) 1241
J. KELLER, G. B. SCHNEIDER, C. M. STANFORD and B. KELLOG, Implant Dent. 12(2003) 175
W.C. A. VROUWENVELDER, C. G. GROOT and K. DE GROOT, J. Biomed. Mater. Res. 27 (1993) 265
D. L. COCHRAN, R. K. SCHENK, A. LUSSI, F. L. HIGGINBOTTOM and D. BUSER, J. Biomed. Mater. Res. 40 (1998) 1
A. WENNERBERG, T. ALBREKTSSON, C. JOHANSSON and B. ERSSON, Biomaterials 17 (1996) 15
A.WENNERBERG, R. OHLSSON, B. G. ROSEN and B. ANDERSSON, Med. Eng. Phys. 18 (1996) 548
A. WENNERBERG, T. ALBREKTSSON and B. ANDERSSON, Int. J. Oral Maxillofac. Implants 11 (1996) 38
A. WENNERBERG, Int. J. Prosthodont. 16(Suppl) (2003) 7–51
T. ALBREKTSSON and A. WENNERBERG, Int. J. Prosthodont. 17 (2004) 536
M. WONG, J. EULENBERGER, R. SCHENK and E. HUNZIKER, J. Biomed. Mater. Res. 29 (1995) 1567
J. LAUSMAA, In Titanium in Medicine (Springer, Berlin, 2001) p.231
A. SCHUH, U. HOLZWARTH, W. KACHLER, J. GOSKE and G. ZEILER, Orthopade 33 (2004) 905
U. GBURECK, A. MASTEN, J. PROBST and R. THULL, Mater. Sci. Eng. 23 (2003) 461
J.A. SHIBLI, E. MARCANTONIO, S. d’AVILA, A. C. GUASTALDI and E. MARCANTONIO, J. Periodontol. 76 (2005) 1092
B.F. SHAHGALDI, E. TAYLOR and J. COMPSON, J. Bone Joint Surg. Br. 82B (Suppl) (2000) 66
L.L. HENCH and J. WILSON, In Introduction to Bioceramics (World Scientific Publishing, London, 1993)
U. GROSS and V. STRUNZ, J. Biomed. Mater. Res. 19 (1985) 251
R. J. COOK, I. THOMPSON, G. PAOLINELIS, P.D. ROBINSON, P. PILECKI and T.F. WATSON in “The use of bioactive glasses in exposed dentine surface repair” IADR (2004) Poster 3464
G. PAOLINELIS, A. BANERJEE, I. THOMPSON, S. ZINELIS, T.F. WATSON and G. ELIADES in “Bioactive glass retention on dentine by air-abrasion application” IADR (2005) Poster 0502
T. KOKUBO, H. KUSHITANI, S. SAKKA, T. KITSUGI and T. YAMAMURO, J. Biomed. Mater. Res. 24 (1990) 721
L.D. WARREN, A.E. CLARK and L.L. HENCH, J. Biomed. Mater. Res. 23 (Suppl. A2) (1989) 201
I.D. XYNOS, A. J. EDGAR, L. D. BUTTERY, L. L. HENCH and J. M. POLAK, J. Biomed. Mater. Res. 55 (2001) 151
I.D. XYNOS, M. V. HUKKANEN, J. J. BATTEN, L. D. BUTTERY, L. L. HENCH and J. M. POLAK, Calcif. Tissue Int. 67 (2000) 321
L.L. HENCH, R. J. SPLINTER, W. C. ALLAN and T. K. GREENLEE, J. Biomed. Mater. Res. 2 (1972) 117
T.B. LOVELACE, J. T. MELLONIG, R. M. MEFFERT, A. A. JONES, P. V. NUMMIKOSKI and D. L. COCHRAN, J. Periodontol. 69 (1998) 1027
H. OONISHI, S. KUSHITANI, E. YASUKAWA, H. IWAKI, L. L. HENCH, J. WILSON, E. TSUJI, T. SUGIHARA, Clin. Orthop. 334 (1997) 316
M.D. ROHRER, R. R. SOBCZAK, H. S. PRASAD and H. F. MORRIS, Int. J. Oral Maxillofac. Implants 14 (1997) 579
H. LIAO, B. FARTASH and J. LI, Clin. Oral Implants Res. 8 (1997) 68
J.T. DOMINICI, J. W. OLSON, M. D. ROHRER and H. F. MORRIS, Implant Dent. 6 (1997) 215
I. ALLAN, H. NEWMAN and M. WILSON, Biomaterials 22 (2001) 1683
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Koller, G., Cook, R.J., Thompson, I.D. et al. Surface modification of titanium implants using bioactive glasses with air abrasion technologies. J Mater Sci: Mater Med 18, 2291–2296 (2007). https://doi.org/10.1007/s10856-007-3137-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10856-007-3137-z