Abstract
The purpose of this study was to compare the anterior and posterior elevation measurements using different reference surfaces (spheric, aspheric, and aspherotoric) with Scheimpflug–Placido topography in simple myopic and keratoconus patients. 600 eyes of 600 patients undergoing screening for keratorefractive surgery (500 simple myopic, 100 keratoconus stage 1 and 2) in Sohag refractive center, Egypt, were examined by Scheimpflug–Placido topography (Sirius, CSO, Italy) for both the anterior and posterior corneal elevation maps using the spheric, aspheric, and aspherotoric reference surfaces. 100 keratoconic eyes showed higher discriminating power using the aspherotoric reference surface in both the anterior and posterior elevation maps. The use of aspherotoric reference surface gives more data for eyes with keratoconus and its use is more informative in screening.
Similar content being viewed by others
References
Belin MW, Khachikian SS (2009) An introduction to understanding elevation-based topography: how elevation data are displayed—a review. Clin Exp Ophthalmol 37(1):14–29. doi:10.1111/j.1442-9071.2008.01821.x
Bessho K, Maeda N, Kuroda T, Fujikado T, Tano Y, Oshika T (2006) Automated keratoconus detection using height data of anterior and posterior corneal surfaces. Jpn J Ophthalmol 50(5):409–416. doi:10.1007/s10384-006-0349-6
Bogan SJ, Waring GO 3rd, Ibrahim O, Drews C, Curtis L (1990) Classification of normal corneal topography based on computer-assisted videokeratography. Arch Ophthalmol 108(7):945–949
Ciolino JB, Khachikian SS, Cortese MJ, Belin MW (2007) Long-term stability of the posterior cornea after laser in situ keratomileusis. J Cataract Refract Surg 33(8):1366–1370. doi:10.1016/j.jcrs.2007.04.016
de Jong T, Sheehan MT, Dubbelman M, Koopmans SA, Jansonius NM (2013) Shape of the anterior cornea: comparison of height data from 4 corneal topographers. J Cataract Refract Surg 39(10):1570–1580. doi:10.1016/j.jcrs.2013.04.032
de Sanctis U, Loiacono C, Richiardi L, Turco D, Mutani B, Grignolo FM (2008) Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus/subclinical keratoconus. Ophthalmology 115(9):1534–1539. doi:10.1016/j.ophtha.2008.02.020
Fam HB, Lim KL (2006) Corneal elevation indices in normal and keratoconic eyes. J Cataract Refract Surg 32(8):1281–1287. doi:10.1016/j.jcrs.2006.02.060
Kovacs I, Mihaltz K, Ecsedy M, Nemeth J, Nagy ZZ (2011) The role of reference body selection in calculating posterior corneal elevation and prediction of keratoconus using rotating Scheimpflug camera. Acta Ophthalmol 89(3):e251–e256. doi:10.1111/j.1755-3768.2010.02053.x
Lim L, Wei RH, Chan WK, Tan DT (2007) Evaluation of keratoconus in Asians: role of Orbscan II and Tomey TMS-2 corneal topography. Am J Ophthalmol 143(3):390–400. doi:10.1016/j.ajo.2006.11.030
Milla M, Pinero DP, Amparo F, Alio JL (2011) Pachymetric measurements with a new Scheimpflug photography-based system: intraobserver repeatability and agreement with optical coherence tomography pachymetry. J Cataract Refract Surg 37(2):310–316. doi:10.1016/j.jcrs.2010.08.038
Nilforoushan MR, Speaker M, Marmor M, Abramson J, Tullo W, Morschauser D, Latkany R (2008) Comparative evaluation of refractive surgery candidates with Placido topography, Orbscan II, Pentacam, and wavefront analysis. J Cataract Refract Surg 34(4):623–631. doi:10.1016/j.jcrs.2007.11.054
Salouti R, Nowroozzadeh MH, Zamani M, Fard AH, Niknam S (2009) Comparison of anterior and posterior elevation map measurements between 2 Scheimpflug imaging systems. J Cataract Refract Surg 35(5):856–862. doi:10.1016/j.jcrs.2009.01.008
Savini G, Barboni P, Carbonelli M, Hoffer KJ (2011) Repeatability of automatic measurements by a new Scheimpflug camera combined with Placido topography. J Cataract Refract Surg 37(10):1809–1816. doi:10.1016/j.jcrs.2011.04.033
Schlegel Z, Hoang-Xuan T, Gatinel D (2008) Comparison of and correlation between anterior and posterior corneal elevation maps in normal eyes and keratoconus-suspect eyes. J Cataract Refract Surg 34(5):789–795. doi:10.1016/j.jcrs.2007.12.036
Sideroudi H, Labiris G, Giarmoukakis A, Bougatsou N, Kozobolis V (2014) Contribution of reference bodies in diagnosis of keratoconus. Optom Vis Sci 91(6):676–681. doi:10.1097/OPX.0000000000000258
Smadja D, Santhiago MR, Mello GR, Krueger RR, Colin J, Touboul D (2013) Influence of the reference surface shape for discriminating between normal corneas, subclinical keratoconus, and keratoconus. J Refract Surg 29(4):274–281. doi:10.3928/1081597X-20130318-07
Sonmez B, Doan MP, Hamilton DR (2007) Identification of scanning slit-beam topographic parameters important in distinguishing normal from keratoconic corneal morphologic features. Am J Ophthalmol 143(3):401–408. doi:10.1016/j.ajo.2006.11.044
Swartz T, Marten L, Wang M (2007) Measuring the cornea: the latest developments in corneal topography. Curr Opin Ophthalmol 18(4):325–333. doi:10.1097/ICU.0b013e3281ca7121
Ucakhan OO, Cetinkor V, Ozkan M, Kanpolat A (2011) Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes. J Cataract Refract Surg 37(6):1116–1124. doi:10.1016/j.jcrs.2010.12.049
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The author has no proprietary interests or conflicts of interest related to this submission.
Rights and permissions
About this article
Cite this article
Mostafa, E.M. Comparison between corneal elevation maps using different reference surfaces with Scheimpflug–Placido topographer. Int Ophthalmol 37, 553–558 (2017). https://doi.org/10.1007/s10792-016-0291-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10792-016-0291-7