Abstract
The aim of this study was to experimentally examine the changes in the transmittances of photocoagulation lasers when surface light scattering increases in AcrySof intraocular lenses (IOLs). SA60AT IOLs (Alcon) were acceleratingly aging for 0, 3, 5, and 10 years to simulate surface light scattering, and the surface light-scattering intensities of both IOL surfaces were measured using a Scheimpflug photographer. The powers of laser beams that passed from a laser photocoagulator through the aged IOLs were measured at 532, 577, and 647 nm. Changes in the laser power and transmittance with the years of aging and the intensities of surface light scattering were examined. Although the intensity of surface light scattering increased with the years of aging, the laser power did not change with the years of aging (P > 0.30, Kruskal–Wallis test). There were no significant changes in the laser transmittance with the years of aging or the laser wavelength (P > 0.30 and 0.57, respectively). The intensity of surface light scattering revealed no significant association with the laser transmittance at any wavelength (P > 0.37, liner regression). The increases in the surface light scattering of the AcrySof IOLs would not influence retinal photocoagulation treatments for up to 10 years after implantation.
Similar content being viewed by others
References
Yaguchi S, Chida M, Nishihara H, Ohnishi T, Ayaki M (2002) Light scattering observed on the surface of acrylic intraocular lenses 10 years after implantation. Nippon Ganka Gakkai Zasshi 106:109–111 Japanese
Nishihara H, Yaguchi S, Onishi T, Chida M, Ayaki M (2003) Surface scattering in implanted hydrophobic intraocular lenses. J Cataract Refract Surg 29:1385–1388
Miyata K, Otani S, Nejima R, Miyai T, Samejima T, Honbo M et al (2009) Comparison of postoperative surface light scattering of different intraocular lenses. Br J Ophthalmol 93:684–687
Miyata K, Honbo M, Otani S, Nejima R, Minami K (2012) Effect on visual acuity of increased surface light scattering in intraocular lenses. J Cataract Refract Surg 38:221–226
Miyata K, Honbo M, Nejima R, Minami K, Amano S (2015) Long-term observation of surface light scattering in a foldable acrylic intraocular lens. J Cataract Refract Surg 41:1205–1209
Matsushima H, Mukai K, Nagata M, Gotoh N, Matsui E, Senoo T (2009) Analysis of surface whitening of extracted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 35:1927–1934
Ong MD, Callaghan TA, Pei R, Karakelle M (2012) Etiology of surface light scattering on hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 38:1833–1844
Kato K, Nishida M, Yamane H, Nakamae K, Tagami Y, Tetsumoto K (2001) Glistening formation in an AcrySof lens initiated by spinodal decomposition of the polymer network by temperature change. J Cataract Refract Surg 27:1493–1498
Werner L (2010) Glistenings and surface light scattering in intraocular lenses. J Cataract Refract Surg 36:1398–1420
Beheregaray S, Yamamoto T, Hiraoka T, Oshika T (2014) Influence on visual function of forward light scattering associated with subsurface nanoglistenings in intraocular lenses. J Cataract Refract Surg 40:1147–1154
Mönestam E, Behnding A (2011) Impact on visual function from light scattering and glistening in intraocular lenses, a long-term study. Acta Ophthalmol 89:724–728
Hayashi K, Hirata A, Yoshida M, Yoshimura K, Hayashi H (2012) Long-term effect of surface light scattering and glistening’s of intraocular lenses on visual function. Am J Ophthalmol 154:240–251
Ogura Y, Ong MD, Akinay A, Carson DR, Pei R, Karakelle M (2014) Optical performance of hydrophobic acrylic intraocular lenses with surface light scattering. J Cataract Refract Surg 40:104–113
Minami K, Maruyama Y, Honbo M, Matsunaga J, Miyata K (2014) In vitro examination of surface light scattering in hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 40:652–656
Onishi T, Kan K, Yaguchi S (1999) Setting the EAS1000 to measure posterior capsular opacification. Folia Ophthalmol Jpn 50:398–402 in Japanese
Shiraya T, Kato S, Shigeeda T (2011) Influence of a yellow-tinted intraocular lens on laser beam transmittance. Acta Ophthalmol 89:37–39
Werner L, Morris C, Liu E, Stallings S, Floyd A, Ollerton A et al (2014) Light transmittance of 1-piece hydrophobic acrylic intraocular lenses with surface light scattering removed from cadaver eyes. J Cataract Refract Surg 40:114–120
Yaguchi S, Nishihara H, Kambhiranond W, Stanley D, Apple DJ (2008) Light scatter on the surface of AcrySof intraocular lenses: part I. Analysis of lenses retrieved from pseudophakic postmortem human eyes. Ophthalmic Surg Lasers Imaging 39:209–213
Das KK, Stover JC, Schwiegerling J, Karakelle M (2013) Technique for measuring forward light scatter in intraocular lenses. J Cataract Refract Surg 39:770–778
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
This research received no specific grant money from any funding agency in the public, commercial, or not-for-profit sectors. The authors have no commercial or proprietary interest in the products or companies mentioned in the current article.
Rights and permissions
About this article
Cite this article
Shiraya, T., Kato, S., Minami, K. et al. Influence of surface light scattering in hydrophobic acrylic intraocular lenses on laser beam transmittance. Int Ophthalmol 37, 251–255 (2017). https://doi.org/10.1007/s10792-016-0256-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10792-016-0256-x