Abstract

The development and performance of a handheld emissometer for the measurement of the emissivity of highly reflective metallic foils used for the insulation of domestic and commercial buildings are described. Reflective roofing insulation based on a thin coating of metal on a more robust substrate is very widely used in hotter climates to reduce the radiant heat transfer between the ceiling and roof in commercial and residential buildings. The required normal emissivity of these foils is generally below 0.05, so stray reflected ambient infrared radiation (IR) makes traditional reflectance-based measurements of emissivity very difficult to achieve with the required accuracy. Many manufacturers apply additional coatings onto the metallic foil to reduce visible glare during installation on a roof, and to provide protection to the thin reflective layer; however, this layer can also substantially increase the IR emissivity. The system as developed at the National Measurement Institute, Australia (NMIA) is based on the principle of measurement of the modulation in thermal infrared radiation, as the sample is thermally modulated by hot and cold air streams. A commercial infrared \(8\,\upmu \hbox {m}\) to \(14\,\upmu \hbox {m}\) band radiation thermometer with a highly specialized stray and reflected radiation shroud attachment is used as the detector system, allowing for convenient handheld field measurements. The performance and accuracy of the system have been compared with NMIA’s reference emissometer systems for a number of typical material samples, demonstrating its capability to measure the absolute thermal emissivity of these very highly reflective foils with an uncertainty of better than \(0.007, k = 2.07, 95\,\%\) .

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. AS/NZS 4201.5:1994, Pliable Building Membranes and Underlays—Method of Test—Emittance (Standards Australia, Sydney, 1994), pp. 1–2

  2. ASTM C835–95 (1995), Standard Test Methods for Total Hemispherical Emittance of Surfaces from \(20\,^\circ \text{ C }\) to \(1400\,^\circ \text{ C }\) (ASTM International, West Conshohocken, PA, 2008), pp. 416–425 (1995)

  3. ASTM C1371–04a (2010)e1, Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers (ASTM International, West Conshohocken, PA, 2010), pp. 1–7

  4. ASTM E408–71 (2008), Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques (ASTM International, West Conshohocken, PA, 2008), pp. 1–3

  5. M.J. Ballico, Measurement of Normal \(8\,\upmu \text{ m }\)\(12\,\upmu \text{ m }\) Infrared Emissivity, NMIA Test Method PM-EADA 8.2.28 (National Measurement Institute of Australia (NMIA), Perth, 2010)

  6. M.J. Ballico, Metrologia 37, 295 (2000)

    Article  ADS  Google Scholar 

  7. M.J. Ballico, E.W.M. Van der Ham, A simple method for the measurement of reflective foil emissivity, in Proceedings of Ninth International Temperature Symposium, Los Angeles, Temperature: its Measurement and Control in Science and Industry, vol. 8, ed. by C.W. Meyer, AIP Conference Proceedings, vol. 1552 (AIP, Melville, NY, 2013), pp. 740–745

  8. H.D. Baehr, K. Stephan, Heat and Mass Transfer (Springer, Berlin, 1998)

    Book  MATH  Google Scholar 

Download references

Acknowledgments

The authors would like to acknowledge the financial support of Martini Industries Polyair and the NSW TechVouchers programme.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to E. W. M. van der Ham.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

van der Ham, E.W.M., Ballico, M.J. Handheld Reflective Foil Emissometer with 0.007 Absolute Accuracy at 0.05. Int J Thermophys 35, 1310–1319 (2014). https://doi.org/10.1007/s10765-014-1639-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-014-1639-8

Keywords

Navigation