The results of numerical hydrothermal modeling of the temperature regimes pf the cooling ponds of the Rostov NPP and fifth unit of the Novovoronezh NPP are presented. The STREAM-3D software package is used in the study to calculate the three-dimensional fields of stratified flows and temperatures in a hydrostatic approximation. Variants of optimizing the thermal regimes that reduce the temperature at the NPP external cooling water intake system are proposed.
Similar content being viewed by others
References
Federal Intellectual Property Service (Rospatent) Computer Program Registration Certificate No. 2014612186, V. V. Belikov, V. V. Kochetkov, and A. B. Rumyantsev, “Software package for calculating hydrothermal regimes and transport of pollutants in watercourses, water bodies, and on the shelf (STREAM 3D),” 2014 [in Russian].
A. N. Militeev, “Hydrothermal modeling of cooling ponds,” Izv. AN SSSR. Énerg. Transp., No. 1 (1981).
M. Sladkevich, A. N. Militeev, N. Rubin, and E. Kit, “Two- and three-dimensional simulation of transport phenomena in a shallow aquatic environment,” J. Hydraul. Eng., 126(2) (2000).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Gidrotekhnicheskoe Stroitel’stvo, No. 10, October 2017, pp. 34 – 42.
Rights and permissions
About this article
Cite this article
Belikov, V.V., Rumyantsev, A.B. & Norin, S.V. Investigation of Variants of Optimizing the Temperature Regimes of Nuclear Power Plant Cooling Ponds by Numerical Methods. Power Technol Eng 51, 653–659 (2018). https://doi.org/10.1007/s10749-018-0887-3