Skip to main content
Log in

Flow Particulars of Some Transient Regimes with Load Shedding on VVER-1000

  • Published:
Atomic Energy Aims and scope

The results of an investigation of the operating regime of a nuclear power plant with VVER-1000 with actuation of accelerated preventative protection at power 100% N nom with one of two turbo pumps switched off are presented. The modeling was performed using the improved accuracy RELAPSCDAPSIM/Mod3.4 code and a corresponding model for the No. 2 unit of the Khmelnitsky NPP. It is shown that the actuation of emergency protection based on the fact that the three main circulation pumps are switched off because of a drop in the feed water in the steam generators cannot be avoided. On the basis of the results obtained, it is proposed that for the second half of the fuel run an emergency protection signal instead of an accelerated preventative protection be immediate generated when one of the turbo pumps is switched off at power level >95% N nom; this will make it possible to secure more forgiving temperature regimes for fuel and equipment, avoid additional thermal cycling loads, and prevent violation of the safe operating limits on the basis of the feed water level in the steam generators.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. I. Arkhangelskaya, “Economic policy during reformation of the electricity and power market and implementation of the investment program of Kontsern Rosenergoatom,” in: Safety, Efficiency, and Economics of Atomic Energy, Moscow (2010), pp. 22–25.

  2. Phare Project SRR 1/95, Validation of Coupled Neutron Kinetic/Thermal-Hydraulic Codes Against Transients Measured in VVER Reactors, European Commission, Final Techn. Rep. (1995).

  3. I. G. Petkevich, G. V. Alekhin, and M. A. Bykov, “Analysis of the indications of neutron flux apparatus in regimes with actuation of accelerated preventative protection for reactor units with the VVER-1000 reactor,” Vopr. At. Nauki Tekhn. Ser. Obesp. Bezop. AES, No. 26, 27–36 (2010).

  4. V. I. Borisenko, I. N. Kadenko, and D. V. Samoilenko, “Particulars of transient processes during actuation of accelerated preventative protection of VVER-1000,” Yad. Fiz. Energet., 10, No. 2, 157–164 (2009).

    Google Scholar 

  5. SCDAP/RELAP5/MOD3.2 Code Manual, Vol. I, SCDAP/RELAP5 Interface Theory, NUREG/CR-6150, INEL-96/0422 (1997).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Translated from Atomnaya Énergiya, Vol. 115, No. 3, pp. 132–136, September, 2013.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Borisenko, V.I., Samoilenko, D.V. & Kadenko, I.N. Flow Particulars of Some Transient Regimes with Load Shedding on VVER-1000. At Energy 115, 156–160 (2014). https://doi.org/10.1007/s10512-013-9764-1

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10512-013-9764-1

Keywords

Navigation