Skip to main content
Log in

Temperature characterization of flip-chip packaged piezoresistive barometric pressure sensors

  • Technical Paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

In order to miniaturize piezoresistive barometric pressure sensors, a new flip-chip packaging technology has been developed. The thermal expansions of chip and package are different. So in a standard flip-chip package the strong mechanical coupling by the solder bumps would lead to stress in the sensor chip, which is unacceptable for piezoresistive pressure sensors. To solve this problem, in the new packaging technology the chip is flip-chip bonded on compliant springs to decouple chip and package. As the first step of the packaging process an under bump metallization (UBM) is patterned on the sensor wafer. Then solder bumps are printed. After wafer-dicing the chips are flip-chip bonded on copper springs within a ceramic cavity housing. Due to the compliance of the springs, packaging stress is induced into the sensor chip. As sources of residual stress the UBM and the solder bumps on the sensor chip were identified. Different coefficients of thermal expansion of the silicon chip, the UBM and the solder lead to plastic straining of the aluminum metallization between UBM and chip. As a consequence the measurement accuracy is limited by a temperature hysteresis. The influence of the chip geometry, e.g., the thickness of the chip or the depth of the cavity, on the hysteresis was investigated by simulation and measurements. As a result of this investigation a sensor chip was designed with very low residual stress and a temperature hysteresis which is only slightly larger than the noise of the sensor.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15

Similar content being viewed by others

References

  • Cabruja E, Collado A, Plaza JA, Esteve J (2005) Piezoresistive accelerometers for MCM-package—part II: the packaging. J Microelectromech Syst 14(4):806–811

    Article  Google Scholar 

  • Campabadal F, Carreras JL, Cabruja E (2006) Flip-chip packaging of piezoresistive pressure sensors. Sens Actuators A 132:415–419

    Article  Google Scholar 

  • Deier E, Wilde J (2003) Thermomechanisches Verhalten der Montageklebung eines mikromechanischen Drucksensors. 14. Symposium Verbundwerkstoffe und Werkstoffverbunde, DGM-Tagung, Wien, pp 649–654

  • Feiertag G, Winter M, Leidl A (2009) Packaging of MEMS microphones. In: Proceedings of the SPIE 7362

  • Lammel G, Gutmann J, Marti L, Dobler M (2009) Indoor navigation with MEMS sensors. Proceedings of the eurosensors XXIII, pp 532–535

  • Plaza JA, Collado A, Cabruja E, Esteve J (2002) Piezoresisitve accelerometers for MCM package. J Microelectromech Syst 11(6):794–801

    Article  Google Scholar 

  • Waber T, Pahl W, Schmidt M, Feiertag G, Stufler S, Dudek R, Leidl A (2013) Flip-chip packaging of piezoresistive barometric pressure sensors. In: Proceedings of the SPIE 8763

  • Wilde J, Deier E (2003) Thermomechanische Einflüsse der Chipklebung auf die Genauigkeit mikromechanischer Drucksensoren Teil 1: Simulation. Tech Mess 70:251–257

    Article  Google Scholar 

  • Zarnik MS, Rocak D, Macek S (2004) Residual stresses in a pressure-sensor package induced by adhesive material during curing: a case study. Sens Actuators A 116:442–449

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to T. Waber.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Waber, T., Pahl, W., Schmidt, M. et al. Temperature characterization of flip-chip packaged piezoresistive barometric pressure sensors. Microsyst Technol 20, 861–867 (2014). https://doi.org/10.1007/s00542-013-2064-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-013-2064-9

Keywords

Navigation