Abstract
The relationships between the epidural pressures following the injection of local anesthetic solution and the spread of epidural analgesia were investigated. In 46 patients, 15 ml of 2% mepivacaine was injected into the lumbar epidural space at a constant rate (1 ml/sec) using an electropowered syringe pump. Injection pressures and residual pressures were recorded and the spread of analgesia to pinprick was assessed. The changes of the epidural pressures during and following the injection of a volume of local anesthetic solution in old subjects were significantly smaller than those in young subjects (P<0.05). The spread of analgesia closely correlated with the epidural pressures during and following the injection of local anesthetic solution. The most close correlation was found between the epidural pressure immediately after the completion of injection and the spread of analgesia (r=−0.5659,P<0.001). In conclusion, the lower the terminal injection pressure and the residual pressures associated with higher age, the wider the spread of epidural analgesia.
Similar content being viewed by others
References
Usubiaga JE, Wikinski JA, Usubiaga LE: Epidural pressures and its relation to spread anesthetic solutions in epidural space. Anesth Analg 46:440–446, 1967
Husemeyer RP, White DC: Lumbar extradural injection pressures in pregnant women, an investigation of relationships between rate of injection, injection pressures and extent of analgesia. Br J Anaesth 52:55–60, 1980
Hirabayashi Y, Matsuda I, Inoue S, Shimizu R: Spread of epidural analgesia following a constant pressure injection, an investigation of relationships between locus of injection, epidural pressure, and spread of analgesia. J Anesth 1:44–50, 1987
Cousins MJ: Epidural neural blockade, Neural Blockade in Clinical Anesthesia & Management of Pain. Edited by Cousins MJ, Bridenbaugh PO. Philadelphia, Lippincott, 1980, p.262
Bromage PR: Epidural compliance, Epidural Analgesia. Edited by Bromage PR, Philadelphia, WB Saunders, 1978, pp.171–175
Pitkin WM: Extradural anestesia, Conduction Anesthesia. Edited by Southworth JL, Hingson RA, Pitkin WM. Piladelphia, Lippincott, 1953, pp.728–748
Matsuda I, Morita K, Yoshizawa M, Ohtake K, Yura M, Ikeda K: The measurement of lumbar resistance by the drip infusion epidural indicator. Jpn J Anesth 31:1081–1086, 1982
Author information
Authors and Affiliations
About this article
Cite this article
Hirabayashi, Y., Matsuda, I., Inoue, S. et al. Epidural pressure and its relation to spread of epidural analgesia. J Anesth 1, 168–172 (1987). https://doi.org/10.1007/s0054070010168
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s0054070010168