Skip to main content
Log in

A comparison of two time-domain analysis procedures in the determination of V˙O2 kinetics by pseudorandom binary sequence exercise testing

  • Original Article
  • Published:
European Journal of Applied Physiology Aims and scope Submit manuscript

Abstract.

The purpose of this study was to apply and compare two time-domain analysis procedures in the determination of oxygen uptake (V˙O2) kinetics in response to a pseudorandom binary sequence (PRBS) exercise test. PRBS exercise tests have typically been analysed in the frequency domain. However, the complex interpretation of frequency responses may have limited the application of this procedure in both sporting and clinical contexts, where a single time measurement would facilitate subject comparison. The relative potential of both a mean response time (MRT) and a peak cross-correlation time (PCCT) was investigated. This study was divided into two parts: a test-retest reliability study (part A), in which 10 healthy male subjects completed two identical PRBS exercise tests, and a comparison of the V˙O2 kinetics of 12 elite endurance runners (ER) and 12 elite sprinters (SR; part B). In part A, 95% limits of agreement were calculated for comparison between MRT and PCCT. The results of part A showed no significant difference between test and retest as assessed by MRT [mean (SD) 42.2 (4.2) s and 43.8 (6.9) s] or by PCCT [21.8 (3.7) s and 22.7 (4.5) s]. Measurement error (%) was lower for MRT in comparison with PCCT (16% and 25%, respectively). In part B of the study, the V˙O2 kinetics of ER were significantly faster than those of SR, as assessed by MRT [33.4 (3.4) s and 39.9 (7.1) s, respectively; P<0.01] and PCCT [20.9 (3.8) s and 24.8 (4.5) s; P<0.05]. It is possible that either analysis procedure could provide a single test measurement of V˙O2 kinetics; however, the greater reliability of the MRT data suggests that this method has more potential for development in the assessment of V˙O2 kinetics by PRBS exercise testing.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Edwards, .A., Claxton, .D. & Fysh, .M. A comparison of two time-domain analysis procedures in the determination of V˙O2 kinetics by pseudorandom binary sequence exercise testing. Eur J Appl Physiol 88, 411–416 (2003). https://doi.org/10.1007/s00421-002-0725-y

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00421-002-0725-y

Navigation