The polyurethane nasolacrimal duct stent for lower tear duct obstruction: long-term success rate and complications

  • Clinical Investigation
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract 

Background: The polyurethane nasolacrimal duct stent is used as an alternative to conventional techniques for treatment of lower tear duct obstruction. The aim of this study was to evaluate the clinical success rate after a follow-up of 2 years. Methods: Nasolacrimal duct stent implantation was attempted in 19 patients with nasolacrimal duct obstruction proven by digital substraction dacryocystography. The median age of the patients was 50 years, and the minimum duration of symptoms was 3 months. Patients were followed up 1 week, 6 months, 1 year and 2 years after the procedure. Results: Eighteen stents were implanted in 17 patients without surgical complications. All stents were proven to be patent at the end of the procedure. Success rate, defined as proportion of patients free of symptoms, was 66.6%, 55.5% and 50% after 1 week, 6 months and 1 year, respectively, and remained unchanged thereafter. Three stents had to be removed between 6 months and 2 years after implantation. Histological examination showed granulation tissue growing into the opening and obstructing the stent in one case. Conclusion: Implantation of a polyurethane nasolacrimal duct stent is an alternative to conventional techniques in lower tear duct obstruction. Its overall success rate is lower than that reported after conventional dacryocystorhinostomy, but the procedure is fast, safe and reversible. Refinement of the surface and stent design may improve results in the future.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 8 February 2000 Revised: 12 April 2000 Accepted: 31 May 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schaudig, U., Maas, R. The polyurethane nasolacrimal duct stent for lower tear duct obstruction: long-term success rate and complications. Graefe's Arch Clin Exp Ophthalmol 238, 733–737 (2000). https://doi.org/10.1007/s004170000187

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004170000187

Keywords

Navigation