Skip to main content
Log in

Effects of chronic low-dose exposure to ionizing radiation on physician microvascular structure revealed by nail fold capillaroscopy

  • Original Article
  • Published:
Radiation and Environmental Biophysics Aims and scope Submit manuscript

Abstract

The aim of this study was to assess the long-term asymptomatic effects of low-dose radiation on microvascular structure among interventional physicians, whose hands are exposed to ionizing radiation during daily practice. The study, approved by the national ethics committee, included 186 radiation-exposed (surgeons, cardiologists, radiologists) and 35 unexposed physicians, all of whom had provided written consent. The subjects completed a questionnaire describing their current and past daily practice, from which tentative estimates of current and cumulative radiation exposure estimates were computed. Subject dermal microcirculation state was assessed by capillaroscopy of the nail fold of eight fingers (thumbs excluded) based on photographs. Two quantitative scores characterizing extravasation and morphological abnormalities based on seven semiquantitative indices were obtained from post hoc coding of the photographs by five capillaroscopists. These evaluations were randomized and blind to the exposure. The effect of the radiation exposure on both abnormality scores was modelled using multilevel proportional odds regression adjusted for potential confounders. The proportion of physicians for which the most frequent act is close to the radiation source was highest among surgeons, but with fewer weekly acts. The median duration of exposure was highest among radiologists and cardiologists. No exposure effect could be detected on the extravasation score. The morphological anomaly score increased significantly with duration of exposure and estimated cumulative exposure among surgeons and interventional radiologists, unlike cardiologists among whom no effect could be detected. It is concluded that the shown effects of chronic low-dose exposure to ionizing radiation on physician microvascular structure reveal the importance of increased exposure monitoring and prevention.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Brumen V, Horvat D, Bonic I (1994) Evaluation of serial application of capillaroscopy, photoplethysmography, and dermothermometry in diagnosis and prevention of radiolesions of peripheral microvessels. Microvas Res 47(2):270–278. doi:10.1006/mvre.1994.1020

    Article  Google Scholar 

  • Domienik J, Brodecki M, Carinou E, Donadille L, Jankowski J, Koukorava C, Krim S, Nikodemova D, Ruiz-Lopez N, Sans-Merce M, Struelens L, Vanhavere F (2011) Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project. Radiat Prot Dosim 144(1–4):442–447. doi:10.1093/rpd/ncq508

    Article  Google Scholar 

  • Domienik J, Brodecki M, Rusicka D (2012) A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology. Radiat Meas 47(2):130–138. doi:10.1016/j.radmeas.2011.12.004

    Article  Google Scholar 

  • Donadille L, Carinou E, Brodecki M, Domienik J, Jankowski J, Koukorava C, Krim S, Nikodemova D, Ruiz-Lopez N, Sans-Merce M, Struelens L, Vanhavere F, Zaknoune R (2011) Staff eye lens and extremity exposure in interventional cardiology: results of the ORAMED project. Radiat Meas 46(11):1203–1209. doi:10.1016/j.radmeas.2011.06.034

    Article  Google Scholar 

  • Feghali J-A, Tagnard -MF, Donadille L, Rehel J-L, Aubert B, Allodji R, Gauron C, Farah J, Clairand I (2014) Statistical analysis of measured operators’ finger doses in interventional radiology. Radioprotection 49:91–99. doi:10.1051/radiopro/2013087

    Article  Google Scholar 

  • Hoerth C, Kundi M, Katzenschlager R, Hirschl M (2012) Qualitative and quantitative assessment of nailfold capillaries by capillaroscopy in healthy volunteers. VASA Zeitschrift fur Gefasskrankheiten J Vasc Dis 41(1):19–26

    Article  Google Scholar 

  • Hofstee HM, Serne EH, Roberts C, Hesselstrand R, Scheja A, Moore TL, Wildt M, Manning JB, Vonk Noordegraaf A, Voskuyl AE, Herrick AL (2011) A multicentre study on the reliability of qualitative and quantitative nail-fold videocapillaroscopy assessment. Rheumatology (Oxford) 51(4):749–755. doi:10.1093/rheumatology/ker403

    Article  Google Scholar 

  • Hyland RA, Yates DH, Benke G, Sim M, Johnson AR (2010) Occupational exposure to asbestos in New South Wales, Australia (1970–1989): development of an asbestos task exposure matrix. Occup Environ Med 67(3):201–206. doi:10.1136/oem.2008.039347

    Article  Google Scholar 

  • ISO (1999) X and gamma reference radiation for calibrating dosimeters and dose-rate meters and determining their response as a function of photon energy—Part3: calibration of area and personal dosimeters and the measurement of their response as a function of energy and angle of incidence. ISO, 4037-3

  • Krim S, Brodecki M, Carinou E, Donadille L, Jankowski J, Koukorava C, Dominiek J, Nikodemova D, Ruiz-Lopez N, Sans-Merce M, Struelens L, Vanhavere F (2011) Extremity doses of medical staff involved in interventional radiology and cardiology: correlations and annual doses (hands and legs). Radiat Meas 46(11):1223–1227. doi:10.1016/j.radmeas.2011.07.010

    Article  Google Scholar 

  • Miller DL (2008) Overview of contemporary interventional fluoroscopy procedures. Health Phys 95(5):638–644. doi:10.1097/01.HP.0000326341.86359.0b

    Article  Google Scholar 

  • Nikodemova D, Brodecki M, Carinou E, Domienik J, Donadille L, Koukorava C, Krim S, Ruiz-Lopez N, Sans-Merce M, Struelens L, Vanhavere F, Zaknoune R (2011) Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign. Radiat Meas 46(11):1210–1215. doi:10.1016/j.radmeas.2011.07.038

    Article  Google Scholar 

  • Pennarola R (1986) Capillary microscopy as preventive medicine in subjects exposed to ionising radiation. Br J Radiol Suppl 19:86–88

    Google Scholar 

  • Rabe-Hesketh S, Skrondal A (2012) Multilevel and longitudinal modeling using Stata. Vol II: categorical responses, counts, and survival. Stata Press, College Station, Tx

    Google Scholar 

  • Togni M, Balmer F, Pfiffner D, Maier W, Zeiher AM, Meier B (2004) Percutaneous coronary interventions in Europe 1992–2001. Eur Heart J 25(14):1208–1213. doi:10.1016/j.ehj.2004.04.024

    Article  Google Scholar 

  • Tomei F, Papaleo B, Fantini S, Iavicoli S, Baccolo TP, Rosati MV (1996) Vascular effects of occupational exposure to low-dose ionizing radiation. Am J Ind Med 30(1):72–77. doi:10.1002/(SICI)1097-0274(199607)30:1<72:AID-AJIM12>3.0.CO;2-5

    Article  Google Scholar 

Download references

Acknowledgments

We acknowledge the important contribution of the late Professor Perdereau, who initiated this project but did not live to see it completed. We would like to thank Dr Donadille (IRSN) for his help in assessing the doses based on actual exposure measurements and Dr Derock who helped with the organization of the data collection. The study was entirely financed by the core funding of the INRS.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Pascal Wild.

Appendix

Appendix

See Tables 5, 6, 7 and 8.

Table 7 Description and modelling of the morphological score including inconsistent scorings
Table 8 Overall modelling of the morphological score, without distinction of job category

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wild, P., Gauron, C., Champion, K. et al. Effects of chronic low-dose exposure to ionizing radiation on physician microvascular structure revealed by nail fold capillaroscopy. Radiat Environ Biophys 55, 71–79 (2016). https://doi.org/10.1007/s00411-015-0631-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00411-015-0631-4

Keywords

Navigation