Abstract
Background and aim
There is still no gold standard technique for graft fixation during anterior cruciate ligament reconstruction. We compared the functional outcomes of patients receiving either ToggleLoc with ZipLoop technology or Translig transverse crosspin device for femoral graft fixation.
Materials and methods
A total of 118 patients were randomly allocated into two groups to receive either Translig® transverse crosspin (Translig group 1: n = 51, mean age 28.34 ± 7.83 years, age 18–40 years) or ToggleLoc with ZipLoop technology (ToggleLoc group: n = 67, mean age 26.85 ± 8.76, age 16-41 years) for femoral graft fixation. Early and 1-year assessment was made with Lysholm knee scale, International Knee Documentation Committee Scoring, Tegner Activity Level Scale, KT-1000 arthrometer and pivot shift test.
Results
Preoperative vs. postoperative functional parameters showed significant improvement in both groups. Two groups were similar in terms of Lysholm knee scale, IKDC and Tegner activity scores (p > 0.05). The KT-1000 arthrometer revealed slightly less anterior sliding in Translig group than that in ToggleLoc group (p > 0.05). ToggleLoc technique allowed a radiographically more horizontal placement of the graft than Translig technique.
Conclusion
Two distinct techniques used in this study are likely to be suitable for femoral graft fixation during anterior cruciate ligament reconstruction with the femoral tunnel being created via anteromedial approach.
Similar content being viewed by others
References
Moses B, Orchard J, Orchard J (2012) Systematic review: annual incidence of ACL injury and surgery in various populations. Res Sports Med 20(3–4):157–179
Spindler KP, Parker RD, Andrish JT, Kaeding CC, Wright RW, Marx RG et al (2013) Prognosis and predictors of ACL reconstructions using the MOON cohort: a model for comparative effectiveness studies. J Orthop Res 31:2–9
Mohtadi NG, Chan DS, Dainty KN, Whelan DB (2011) Patellar tendon versus hamstring tendon autograft for anterior cruciate ligament rupture in adults. Cochrane Database Syst Rev (9):CD005960
Firat A, Catma F, Tunc B, Hacihafizoglu C, Altay M, Bozkurt M et al (2014) The attic of the femoral tunnel in anterior cruciate ligament reconstruction: a comparison of outcomes of two suspensory femoral fixation systems. Knee Surg Sports Traumatol Arthrosc 22:1097–1105
Rylander L, Brunelli J, Taylor M, Baldini T, Ellis B, Hawkins M et al (2014) A biomechanical comparison of anterior cruciate ligament suspensory fixation devices in a porcine cadaver model. Clin Biomech (Bristol, Avon) 29:230–234
Eguchi A, Ochi M, Adachi N, Deie M, Nakamae A, Usman MA (2014) Mechanical properties of suspensory fixation devices for anterior cruciate ligament reconstruction: comparison of the fixed-length loop device versus the adjustable-length loop device. Knee. doi:10.1016/j.knee.2014.02.009
Gifstad T, Drogset JO, Grøntvedt T, Hortemo GS (2013) Femoral fixation of hamstring tendon grafts in ACL reconstructions: the 2-year follow-up results of a prospective randomized controlled study. Knee Surg Sports Traumatol Arthrosc (Epub ahead of print)
Firat A, Catma F, Tunc B, Hacihafizoglu C, Altay M, Bozkurt M, Kapicioglu MI (2014) The attic of the femoral tunnel in anterior cruciate ligament reconstruction: a comparison of outcomes of two suspensory femoral fixation systems. Knee Surg Sports Traumatol Arthrosc 22:1097–1105
Nebelung S, Deitmer G, Gebing R, Reichwein F, Nebelung W (2012) Anterior cruciate ligament reconstruction using biodegradable transfemoral fixation at 5-year follow-up: clinical and magnetic resonance imaging evaluation. Knee Surg Sports Traumatol Arthrosc 20:2279–2286
Kruse LM, Gray B, Wright RW (2012) Rehabilitation after anterior cruciate ligament reconstruction: a systematic review. J Bone Joint Surg Am 94(19):1737–1748
Lee JJ, Otarodifard K, Jun BJ, McGarry MH, Hatch GF 3rd, Lee TQ (2011) Is supplementary fixation necessary in anterior cruciate ligament reconstructions? Am J Sports Med 39:360–365
Colvin A, Sharma C, Parides M, Glashow J (2011) What is the best femoral fixation of hamstring autografts in anterior cruciate ligament reconstruction? A meta-analysis. Clin Orthop Relat Res 469:1075–1081
Petre BM, Smith SD, Jansson KS, de Meijer PP, Hackett TR, LaPrade RF et al (2013) Femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction: a comparative biomechanical study. Am J Sports Med 41(2):416–422
Conner CS, Perez BA, Morris RP, Buckner JW, Buford WL Jr, Ivey FM (2010) Three femoral fixation devices for anterior cruciate ligament reconstruction: comparison of fixation on the lateral cortex versus the anterior cortex. Arthroscopy 26:796–807
Silva A, Sampaio R, Fernandes R, Pinto E (2014) Is there a role for adult non-cultivated bone marrow stem cells in ACL reconstruction? Knee Surg Sports Traumatol Arthrosc 22:66–71
Dorozhkin SV (2011) Biocomposites and hybrid biomaterials based on calcium orthophosphates. Biomatter 1(1):3–56. doi:10.4161/biom.1.1.16782
Asik M, Sen C, Tuncay I, Erdil M, Avci C, Taser OF (2007) The mid- to long-term results of the anterior cruciate ligament reconstruction with hamstring tendons using Transfix technique. Knee Surg Sports Traumatol Arthrosc 15:965–972
Nebelung S, Deitmer G, Gebing R, Reichwein F, Nebelung W (2012) Anterior cruciate ligament reconstruction using biodegradable transfemoral fixation at 5-year follow-up: clinical and magnetic resonance imaging evaluation. Knee Surg Sports Traumatol Arthrosc 20:2279–2286
Choi NH, Son KM, Yoo SY, Victoroff BN (2012) Femoral tunnel widening after hamstring anterior cruciate ligament reconstruction with bioabsorbable transfix. Am J Sports Med 40:383–387
Sawyer GA, Anderson BC, Paller D, Heard WM, Fadale PD (2013) Effect of interference screw fixation on ACL graft tensile strength. J Knee Surg 26:155–159
Barrow AE, Pilia M, Guda T, Kadrmas WR, Burns TC (2014) Femoral suspension devices for anterior cruciate ligament reconstruction: do adjustable loops lengthen? Am J Sports Med 42:343–349
Conflict of interest
None declared.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zehir, S., Zehir, R. Suspensory fixation versus novel transverse crosspin for femoral fixation in anterior cruciate ligament reconstruction. Arch Orthop Trauma Surg 134, 1579–1585 (2014). https://doi.org/10.1007/s00402-014-2062-0
Received:
Published:
Issue Date: