Skip to main content
Log in

Tension band suturing for the treatment of displaced type 2 lateral end clavicle fractures

  • Trauma Surgery
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Introduction

Non-operative treatment of Neer type 2 lateral end clavicle fractures presents a difficult problem due to the high incidence of non-union, delayed union and resulting shoulder girdle instability. Operative techniques described may require extensive soft tissue reconstruction, implant removal or lead to implant failure.

Materials and methods

We report a modified tension band suturing technique for the treatment of these lateral end displaced clavicle fractures that avoids these problems of extensive soft tissue dissection, implant removal or implant failure. Ten patients were reviewed clinically, radiologically and with Constant assessment score outcomes using the tension band suture for the treatment of these fractures.

Results

All the fractures had healed at a mean follow-up of 9.2 weeks (range 6–16 weeks) with a mean Constant score of 91 and the power was comparable to the normal shoulder using the Nottingham Myometer.

Conclusion

The results of this pilot study for treatment of Neer’s type 2 lateral end clavicle fractures are very encouraging. We do recommend the need for a prospective larger study of this technique for the treatment of Neer type 2 lateral end clavicle fracture to evaluate this technique further.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Ballmer FT, Gerber C (1973) Coracoclavicular screw fixation for unstable fractures of the distal clavicle. A report of 5 cases. J Bone Joint Surg Br 73(2):291–294

    Google Scholar 

  2. Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164

    PubMed  Google Scholar 

  3. Edwards DJ, Kavanagh TG, Flannery MC (1992) Fractures of the distal clavicle: a case for fixation. Injury 23(1):44–46

    Article  PubMed  CAS  Google Scholar 

  4. Eskola S, Vainionpaa S, Patiala H, Rokkanen P (1987) Outcome of operative treatment in fresh lateral clavicular fracture. Ann Chir Gynaecol 76:167–169

    PubMed  CAS  Google Scholar 

  5. Flinkkila T, Ristiniemi J, Hyvonen P, Hammleinen M. (2002) Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation. Acta Orthop Scand 73(1):50–53

    Article  PubMed  Google Scholar 

  6. Goldberg JA, Bruce WJ, Sonnabend DH, Walsh WR (1997) Type II fractures of the distal clavicle: a new surgical technique. J Shoulder Elbow Surg 6:380–382

    Article  PubMed  CAS  Google Scholar 

  7. Kona J, Bosse MJ, Staheli JW, Rosseau RL (1990) Type II distal clavicle fractures: a retrospective review of surgical treatment. J Orthop Trauma 4(2):115–120

    Article  PubMed  CAS  Google Scholar 

  8. Levy O (2003) Simple, minimally invasive surgical technique for treatment of type 2 fractures of the distal clavicle. J Shoulder Elbow Surg 12(1):24–28

    Article  PubMed  Google Scholar 

  9. Mall JW, Jacobi CA, Phillipp AW, Peter FJ (2002) Surgical treatment of fractures of the distal clavicle with polydioxanone suture tension band wiring: an alternative osteosynthesis. J Orthop Sci 7(5):535–537

    Article  PubMed  CAS  Google Scholar 

  10. Nadarajah R, Mahaluxmivala J, Amin A, Goodier DW (2005) Clavicular hook-plate: complications of retaining the implant. Injury 36(5):681–683

    Article  PubMed  CAS  Google Scholar 

  11. Neer CS (1968) Fractures of the distal third of the clavicle. Clin Orthop 58:43–50

    PubMed  Google Scholar 

  12. Robinson CM, Cairns DA (2004) Primary nonoperative treatment of displaced lateral fractures of the clavicle. J Bone Joint Surg Am 86-A(4):778–782

    PubMed  Google Scholar 

  13. Scadden JE, Richards R (2005) Intramedullary fixation of Neer type II fracture of the distal clavicle with AO/ASIF screw. Injury 36:1172–1175

    Article  PubMed  CAS  Google Scholar 

  14. Tambe AD, Motkar P, Qamar A, Drew S, Turner SM (2005) Fracture of distal third of the clavicle treated by hook plate. Int Orthop 19:1–4

    Google Scholar 

  15. Yamaguchi H, Arakawa H, Kobayachi M (1998) Results of Bosworth method for unstable fractures of the distal clavicle. Int Orthop 22:366–368

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. P. Badhe.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Badhe, S.P., Lawrence, T.M. & Clark, D.I. Tension band suturing for the treatment of displaced type 2 lateral end clavicle fractures. Arch Orthop Trauma Surg 127, 25–28 (2007). https://doi.org/10.1007/s00402-006-0197-3

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-006-0197-3

Keywords

Navigation