Abstract
Background
“Cardiac memory” (CM) refers to a change in repolarization induced by an altered pathway of activation. The effects of biventricular pacing on CM induction have not been investigated.
Objective
To investigate the development of CM during cardiac resynchronization therapy (CRT) through vectorcardiography (VCG).
Methods
Eleven patients undergoing CRT were enrolled. VCG was acquired during spontaneous ventricular activation at baseline and during AAI and DDD pacing immediately after and 7, 14, 21 and 60 days after the implantation.
Results
At 1-week follow-up, during AAI pacing T vector angles significantly changed (azimuth 23 ± 19°; p = 0.002; elevation 23 ± 27°; p = 0.019) and magnitude significantly increased (baseline 1.13 ± 0.69 mV; 7 days: 1.77 ± 1.27 mV; p = 0.026). T angle changes remained stable throughout the follow-up period while a further significant increase in magnitude was observed at 60 days (2.21 ± 1.50 mV; p = 0.01 vs. baseline and p = 0.04 vs. 7 days). Paced T vector magnitude at implant (2.24 ± 1.25 mV) decreased significantly at 7 days (1.64 ± 1.26 mV; p = 0.030) with a further significant decrease at 60 days (1.40 ± 1.18 mV; p = 0.003 vs. baseline; p = 0.02 vs. 7 days).
Conclusion
CRT induces a significant change in T vector magnitude, azimuth, and elevation after resumption of spontaneous ventricular activation after 7 days from implantation. While further changes in T vector angle were not observed, after 2 months of CRT a significant decrease of paced T vector magnitude and a significant increase of spontaneous T vector magnitude were observed.
Similar content being viewed by others
References
Chatterjee K, Harris A, Davies G, Leatham A (1969) Electrocardiographic changes subsequent to artificial ventricular depolarization. Br Heart J 31:770–779
Chatterjee K, Harris AM, Davies JG, Leatham A (1969) T-wave changes after artificial pacing. Lancet 2(7629):1061–1063
Rosenbaum MB, Blanco HH, Elizari MV, Lazzari JO, Davidenko JM (1982) Electrotonic modulation of the T wave and cardiac memory. Am J Cardiol 50:213–222
Wecke L, Gadler F, Linde C, Lundahl G, Rosen MR, Bergfeldt L (2005) Temporal characteristics of cardiac memory in humans: vectorcardiographic quantification in a model of cardiac pacing. Heart Rhythm 2:28–34
Shvilkin A, Bojovic B, Vajdic B, Gussak I, Zimetbaum P, Josephson ME (2009) Vectorcardiographic determinants of cardiac memory during normal ventricular activation and continuous ventricular pacing. Heart Rhythm 6:943–948
Abraham WT, Fisher WG, Smith AL et al (2002) Cardiac resynchronization in chronic heart failure. N Engl J Med 346:1845–1853
Bristow MR, Saxon LA, Boehmer J et al (2004) Cardiac resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 350:2140–2150
Cleland JG, Daubert JC, Erdmann E et al (2005) The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 352:1539–1549
Ricci R, Pignalberi C, Ansalone G et al (2002) Early and late QRS morphology and width in biventricular pacing: relationship to lead site and electrical remodeling. J Interv Card Electrophysiol 6:279–285
Barold SS, Herweg B, Giudici M (2005) Electrocardiographic follow up of biventricular pacemakers. ANE 10(2):231–255
Barold SS, Giudici CM, Herweg B (2006) Importance of the surface electrocardiogram for the assessment of cardiac resynchronization. In: Yu CM, Hayes DL, Auricchio A (eds) Cardiac resynchronization therapy, 2nd edn. Blackwell Futura, Malden, pp 309–323
Kenny T (2007) The nuts and the bolts of cardiac resynchronization therapy. Blackwell Futura (St. Jude Medical), Malden pp 93–102; 135–143
ACC/AHA/HRS (2008) Guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology/American Heart Association task force on practice guidelines (writing committee to revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. JACC 51(21):e1–62
Ziegler R, Bloomfield DK (1970) A study of the normal QRS-T angle in the frontal plane. J Electrocardiol 3:161–167
Alessandrini RS, McPherson DD, Kadish AH, Kane BJ, Goldberger JJ (1997) Cardiac memory: a mechanical and electrical phenomenon. Am J Physiol 272:H1952–H1959
Rosen MR, Cohen IS, Danilo P Jr et al (1998) The heart remembers. Cardiovasc Res 40:469–482
Shvilkin A, Danilo P Jr, Wang J, Burkhoff D, Anyukhovsky EP, Sosunov EA, Hara M, Rosen MR (1998) Evolution and resolution of long-term cardiac memory. Circulation 97:1810–1817
Fantoni C, Auricchio A (2006) Electrical activation sequence. In: Yu CM, Hayes DL, Auricchio A (eds) Cardiac resynchronization therapy, 2nd edn. Blackwell Futura, Malden, pp 35–54
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Padeletti, L., Fantappiè, C., Perrotta, L. et al. Cardiac memory in humans: vectocardiographic quantification in cardiac resynchronization therapy. Clin Res Cardiol 100, 51–56 (2011). https://doi.org/10.1007/s00392-010-0209-8
Received:
Accepted:
Published: