Introduction

For many years there have been discussions in the literature relating to the stability of gadolinium (Gd)-based contrast agents (GBCAs). The recent focus on the rare, but very serious disorder nephrogenic systemic fibrosis (NSF), characterised by fibrosis of the skin and other tissues throughout the body, has led to speculation about the mechanisms involved in the development of this disease, and the role that Gd may play if released from the GBCAs (e.g. see [16]). Accordingly, it is of interest to know how much of the Gd in an injected dose of GBCA may be released in the body, e.g. by the process termed dechelation or transmetallation. To our knowledge, there have been no reliable data in the literature to unequivocally demonstrate whether Gd present in tissues is still chelated or separated from the chelate. The aim of the present study was to investigate this area of uncertainty by analysing tissue samples for concentrations of both chelate and Gd separately following injection of gadodiamide (Omniscan, GE Healthcare, Princeton, N.J., USA) containing 14C-labelled GdDTPA-BMA in rats.

The stability of GBCAs has been studied using different analytical methods, but much of the published information is based on in vitro studies performed under conditions that are far from physiological, and several of the in vivo studies do not contain sufficient data to support the conclusions drawn. Missing information in such studies includes lack of quality control data for any free Gd in the solutions injected [7, 8], interpreting Gd present in tissue samples as being due to Gd released from the GBCAs without measuring the chelate (e.g. [912]), or not taking the amount of extra chelate added to the commercial preparations into consideration when interpreting data [13, 14]. We therefore initiated a study to investigate the fate of GdDTPA-BMA following intravenous injection in rats using analytical techniques that cannot be used in human studies, such as quantitative whole-body autoradiography (QWBA) and analyses of tissue samples for the content of both DTPA-BMA and Gd. Several strategies are, at least in theory, possible to use in such a study. We have avoided using 153Gd as, from previous experience, we found that it may give radiolysis of DTPA-BMA and lead to misinterpretation of results. For instance, any radiolysis of the sample may complicate the interpretation of the data as dechelation because the chemical instability of the substance may be difficult to differentiate from radiolysis. To avoid this, we radiolabelled the chelate only and injected Omniscan with the addition of trace amounts of Gd[14C]DTPA-BMA intravenously into rats. The content of tissue sample homogenates from selected organs were quantified for the amount of 14C-labelled chelate (DTPA-BMA) by using beta-counting, and for Gd using inductively coupled plasma atomic emission spectroscopy (ICP-AES) or inductively coupled plasma sector field mass spectrometry (ICP-SF-MS). Beta-counting was performed on samples combusted in a sample oxidiser, i.e. a process where the radioactivity is transferred into 14CO2 and trapped before counting in order to avoid any quenching. QWBA was used to visualise the biodistribution of the 14C-labelled chelate in the whole animal.

The data obtained show a very similar rate of clearance for radioactivity and Gd from most tissues, and that measurements of Gd content in tissue samples cannot be used to estimate the amount of Gd released from the chelate.

Materials and methods

Materials

DTPA-BMA was radiolabelled with 14C in the positions shown in the insert of Fig. 1; Gd was added, and the Gd[14C]DTPA-BMA obtained had a specific activity of 15 mCi/mmol (26.3 µCi/mg). The radiolabelled product was supplied as a dry substance (GE Healthcare, Cardiff, UK). Omniscan, i.e. the commercial agent from GE Healthcare (Princeton, N.J., USA) contains 0.5 M gadodiamide (GdDTPA-BMA) and 0.025 M caldiamide (CaDTPA-BMA). All other chemicals used were of analytical quality. Water was purified by reverse osmosis, ion exchanged and filtered through a 0.45-µm filter on a Milli-Q Reagent Water System (Millipore, Billerica, Mass., USA).

Fig. 1
figure 1

Chromatographic profile obtained following HPLC analyses of Gd[14C]DTPA-BMA using a radiochemical detector. The radiochemical purity was estimated to be at least 98% based on such chromatograms. The 14C-labelling positions are shown in the insert (Gd not shown in order to better visualise the labelling positions)

Quality control and stability of radiolabelled substance

The radiolabelled substance was tested for radiochemical purity using HPLC with online radiochemical detection. An HP 1100 system (Agilent Technologies, Santa Clara, Calif., USA) coupled to a Radiomatic 150TR Flow Scintillation Analyzer (PerkinElmer, Waltham, Mass.) was used with an ACE 3 AQ, 150 × 4 mm analytical column (Advanced Chromatography Technologies, Aberdeen, Scotland) operated at 25°C. The mobile phase was 0.2 M ammonium acetate: acetonitrile; 99:1 (v/v) run isocratic at 0.8 ml/min, and the flow cocktail was Ultima-Flo M (PerkinElmer) run at 2.4 ml/min. The substance was dissolved in sterile water to a radioactive concentration of 2.5 MBq/ml, kept at 6°C, and 10 µl was injected for each analysis. The radiochemical purity was shown to be greater than 98%; no changes in the purity profile could be seen after 6 months storage at either 2–8°C or below −15°C. A typical chromatogram is shown in Fig. 1.

Animals and experimental design

Male Sprague Dawley rats, weighing 165–205 g, were obtained from Scanbur, Sweden. The animals were identified by numbered ear tags and kept in polycarbonate cages (two per cage). The rats were housed in an animal room with a light/dark cycle of 12 h, temperature 21 ± 2°C and relative humidity of 55 ± 10%. They had access ad libitum to municipally supplied tap water and Rat and Mouse No. 1 Maintenance Diet (RM1) from Special Diet Services, UK. All animal experiments complied with local legal requirements and internal guidelines.

Fifteen rats were randomly allocated to five groups, each containing three rats. The rats were anaesthetised by isoflurane to surgical level and injected intravenously into a lateral tail vein with Omniscan containing trace amounts of Gd[14C]DTPA-BMA. A dose of 0.5 mmol Gd/kg body weight was given to each animal. The injection solution contained 0.404 mmol/ml GdDTPA-BMA and 0.0202 mmol/ml CaDTPA-BMA (excess chelate in the Omniscan formulation) and 0.00679 mmol/ml Gd[14C]DTPA-BMA. Thus, approximately 1.7% of the injected Gd was bound to the radiolabelled substance and there was approximately three-times more CaDTPA-BMA present than the added Gd[14C]DTPA-BMA. The dose administered in this study was 0.5 mmol/kg, compared with a standard clinical dose of 0.1 mmol/kg. At 1, 4, and 24 h, and 3 and 7 days following injection of the test substance, animals were killed with an overdose of 25 mg/ml Pentothal Natrium (4 ml/kg b.w.). Each rat was immediately coated with aqueous 2% carboxymethyl cellulose (CMC), immersed in liquid nitrogen and stored at −20°C until prepared for QWBA analyses.

QWBA

QWBA analysis was performed as described earlier [15]. In short, the animals were embedded in 2% carboxymethyl cellulose (CMC), immersed in a hexane/dry ice bath (−80°C) for 30 min and frozen overnight at −20°C, before sectioning at a thickness of 25 μm at three to five different levels. The sections were prepared by using a Leica Cryomicrotome CM3600 at −20°C and exposed for 7 days to imaging plates (FUJI BAS III Imaging Plates, Japan) before imaging using a Fujifilm BioImager Analyzer BAS 2500 with BASReader Software version 2.21 (Fuji Photo Film). The resulting images were imported into AIDA software version 3.25 (raytest, Straubenhardt, Germany) for quantification. All visible organs were measured and compared with the calibration standards included as detailed previously [15].

Quantification of radioactivity and Gd in tissue samples

From the part of the animal not used for QWBA (approximately half of each animal), representative samples of liver, kidney, lung, skin, muscle and bone (femur) were dissected out. The bone samples were further separated into bone matrix and bone marrow. The tissue samples from liver (obtained from each of the three animals at each time point) were homogenised, and each homogenate and the tissue samples from the other organs were divided into two replicates, one for determination of Gd and one for radioactivity. The bone marrow samples were not analysed because too little material was obtained.

The quantification of Gd by ICP-AES and ICP-SF-MS was carried out as follows: 0.3–1 g of liver, kidney, lung, skin and muscle (wet weight) were digested with nitric acid and hydrogen peroxide at 90°C for 4 h in polypropylene tubes. The samples were analysed by using a Perkin Elmer Optima 3300 DV ICP-AES instrument (radial mode) and by using the Gd 336.223-nm emission line for the liver samples and the Gd 342.247-nm emission line for kidney, lung, skin and muscle samples. Scandium was used as an internal standard and analysed by using the 424.683-nm emission line. Quality control samples were prepared by spiking the NIST (National Institute of Standards and Technology, USA) bovine liver SRM 1577b with known amounts of Gd. The accuracy was within the range 102–103% of added Gd and the repeatability (within day precision) was within the range 1.0–1.4% relative standard deviation (RSD). The detection limit was 0.1 µg Gd/g tissue. The femur bone matrix samples (0.05–0.2 g) were digested with nitric acid at 90°C for 3 h in polypropylene tubes. Europium was added as an internal standard and the samples were diluted to 50 ml. The bone samples were analysed by using a Thermo Finnigan Element2 ICP-SF-MS instrument by using the isotopes 157Gd (analyte) and 153Eu (internal standard) in low-resolution mode. Quality control samples were prepared by spiking the NIST bovine liver SRM 1577b and Weifa bone powder (Weifa, Norway) with known amounts of Gd. The accuracy was within the range 101–106% and the repeatability was within the range 0.3–2.7% RSD. The detection limit was 0.02 µg Gd/g tissue.

The radioactivity of the tissue samples was measured following combustion in a sample oxidizer (Model 307 Packard; PerkinElmer Life and Analytical Sciences, Boston, Mass.) and beta-counting using a Packard Tri-Carb 2700 TR liquid scintillation analyzer (PerkinElmer Life and Analytical Sciences) as described previously [15]. The recovery from the sample oxidiser was found to be 97.5 ± 0.7%.

The following estimates of relative organ weight (g/100 g body weight) were used to quantify the percentage of injected dose recovered per organ or tissue as it was not possible to weigh all organs in this study (when measuring radioactivity of tissue samples from the part of the animal not used for QWBA): femur bone matrix 0.4%; kidney, 1.2%; lung, 1.2%; liver, 4.9%; skin and fur, 18%; muscle, 43% (GE Healthcare historical data).

Results

Representative QWBA pictures obtained 1, 4 and 24 h, and 3 and 7 days after injection of Omniscan with trace amounts of 14C-labelled GdDTPA-BMA are shown in Fig. 2. The image obtained 1 h after injection shows widespread biodistribution as expected for an extracellular contrast agent, rapid urinary excretion was illustrated by high concentrations of radioactivity in the kidney and bladder. Moreover, radioactivity was observed in the oesophagus and intestine. As can be seen from the image taken 4 h after injection, the radioactivity is rapidly excreted via the urinary tract as previously described [16] with the highest concentration of the radioactivity present in the content of the intestine, the kidney cortex, liver and skin. The images show increased concentrations of the radiolabelled substance in the intervertebral discs of the spinal column (observed up to 24 h after injection, although visible only in the 1-h image in Fig. 2), in the dermis, and also as a rim surrounding large bones such as the femur although not in the plane of section in the pictures shown; see also data for bone and bone marrow in Table 1). The images obtained at 3 and 7 days after injection show the highest concentration of radioactivity in kidney cortex, but also the presence of radioactivity in some other organs, including skin/fur. The amounts of radioactivity in the different tissues/organs estimated from the QWBA images are detailed in Table 1.

Fig. 2
figure 2

Representative QWBA pictures obtained of rats 1, 4 and 24 h, and 3 and 7 days (from left to right) after injection of Omniscan with trace amounts of Gd[14C]DTPA-BMA. See the Materials and methods section for further details

Table 1 Mean estimated amounts of 14C-labelled substance in selected organs/tissues (kBq/g tissue) based on the QWBA pictures for rats injected with Omniscan with trace amounts of 14C-labelled GdDTPA-BMA (DL detection limit)

The data obtained after analyses of tissue homogenate samples from kidney, liver, lung, muscle, skin and femur bone matrix are given in Tables 2 and 3. These data were recalculated to be given as percentage of injected dose per organ; such data are shown for the radioactivity in Fig. 3a and for Gd in Fig. 3b; in Fig. 3c the sum of these Gd data and radioactivity data are compared in the same plot. In tissues containing the highest concentrations of radioactivity, there was an excellent agreement between the quantitative radioactivity data obtained with QWBA and beta-counting. For the first four time points the beta-counting data were 105 ± 7% (mean ± standard deviation) of that obtained from QWBA for kidney and 100 ± 10% for liver. Lower values obtained with beta-counting of skin and fur compared with QWBA (69 ± 10%) were probably due to the presence of some muscle tissue in the skin and fur homogenates. Similar comparison was not possible for lung and muscle because of the much lower radioactivity present in these tissues; the radioactivity was below the quantification limit in the autoradiography images for muscle by 24 h after injection (Table 1). As the beta-counting data in general give better sensitivity and accuracy than the QWBA data, and the beta-counting data were obtained by analysing the same tissue samples as those used for Gd analyses, it is only the quantitative data obtained after sample oxidation and beta-counting that are described and discussed below. The quantitative data obtained with the two techniques were well above the detection limits, i.e. the two analytical methods gave sufficiently robust data.

Fig. 3a–c
figure 3

Analyses of tissue homogenate samples obtained from kidney (●), liver (■), lung (▲), muscle (○), skin (□), and femur bone matrix ( with dotted line) at 4 and 24 h, and 3 and 7 days after injection of Omniscan with trace amounts of Gd[14C]DTPA-BMA. a The percentage of injected dose of the radioactivity per organ is shown for all tissues at all time points. b The percentage of the injected dose of Gd is shown for all samples at all time points. c The sum of the radioactivity (◊) and Gd (♦) data for the six tissues shown in a and b is compared in the same plot. The 1-h data are not included in the figure in order to expand the y-scale for the later time points

Table 2 Estimated amounts of Gd (µg Gd/g tissue) in selected organs/tissues from rats injected with Omniscan with trace amounts of 14C-labelled GdDTPA-BMA. Data are given as mean ± SD (n = 3)
Table 3 Estimated amounts of 14C-labelled substance (dpm/g tissue) in selected organs/tissues from rats injected with Omniscan with trace amounts of 14C-labelled GdDTPA-BMA. Data are given as mean ± SD (n = 3)

As can be seen from Fig. 3, the clearance curves for the radioactivity and Gd are very similar for all tissues analysed and do not show significant differences, except for the femur bone matrix. The data in Fig. 3c show that 0.75 ± 0.08% of the injected dose of Gd was present 3 days after injection (sum for kidneys, femurs, liver, lung, muscle and skin) with very similar amounts of DTPA-BMA present in these samples (0.72 ± 0.04% of the injected dose). In samples obtained 7 days after injection, 0.54 ± 0.08% of Gd and 0.38 ± 0.06% of DTPA-BMA were present in these samples.

Discussion

The aim of this investigation in rats was to study the fate of trace amounts of 14C-labelled GdDTPA-BMA in Omniscan, i.e. the commercial product administered to patients containing 5% CaDTPA-BMA, after intravenous administration. By spiking the Omniscan solution before injection with Gd[14C]DTPA-BMA, it was possible to image the whole body biodistribution of the chelate DTPA-BMA. Moreover, the radiolabelled chelate and Gd could be estimated in the same tissue samples taken from the same animals as those used for QWBA. By spiking Omniscan (containing excess CaDTPA-BMA) with trace amounts of Gd[14C]DTPA-BMA, we could be sure that even if a small excess of Gd should be present in the laboratory-prepared Gd[14C]DTPA-BMA, it would be bound by the excess chelate, upon injection to the animal, and therefore would not have any effect on the data obtained.

The whole-body autoradiography images show higher concentrations of radioactivity in the intervertebral discs of the spinal column, in the dermis of the skin, and as a rim surrounding large bones such as the femur compared with the surrounding tissues. It could not be determined whether the rim surrounding large bones is due to binding to the periosteum (connective tissue around the bone) or the bone surface. The data thus show that the agent enters different organs or organ compartments and the clearance kinetics is different from each.

Regarding discussions about NSF and the presence of Gd in skin, it should be noted that very similar concentrations of 14C and Gd were present in the samples obtained during the first 3 days after injection. Thus, the measurements of Gd only in such samples cannot be used to quantify the amount of dechelation (release of Gd from the chelate), contrary to what often is described in the literature (see discussion below). Of the residual amount of the injected substance that was left in the rat 3 and 7 days (0.75% and 0.54%, respectively) after injection of Omniscan spiked with trace amounts of 14C-labelled GdDTPA-BMA, very small amounts of Gd (less than 0.2% of the injected dose) were not co-localised with the intact radiolabelled DTPA-BMA. Increased amounts of radioactivity in the oesophagus and intestine could be due to rats ingesting radiolabelled urine whilst grooming, as well as ingestion of radioactive stools by coprophagy (Fig. 2, image 1 h post-injection). It was not possible to obtain reliable estimates of the amount of the injected dose that may have entered the animals via the oral route.

To our knowledge, measurements of both Gd and the chelate in tissue samples from the same animals have not been published for any of the other GBCAs on the market. The present data clearly show the importance of measuring both Gd and the chelate in tissues before drawing any conclusions about the stability of different agents in animal studies. It should be stressed that the present data were obtained using a single dose, which was close to that used clinically, contrary to much of the animal data reported in the literature for recovery of Gd in tissue samples, and which are often obtained following repeated injections of very high doses of Gd-chelates (up to 20 injections with 25-times the standard clinical imaging dose [11, 12]).

The present data are important in relation to conclusions drawn in several earlier publications aimed at describing the stability of GBCAs. Firstly, we would like to stress that ICP-MS, or similar techniques such as ICP-AES, only measure the concentration of inorganic metals such as Gd, and cannot be used to assess whether or not Gd is still bound to the chelate without using additional methods. Despite this, there are several publications where this issue is not addressed, and where the presence of Gd in tissue samples obtained after intravenous injection is interpreted as evidence of dechelation of the agents. To rectify this deficiency in the published literature, our strategy was to combine ICP-AES/ICP-SF-MS measurements of Gd, together with beta-counting of the radiolabelled chelate following injection of Omniscan-added trace amounts of Gd[14C]DTPA-BMA. Another possible approach is to use ICP-MS as a detector after chromatographic separation, but no such methods are available, probably because the tissue extraction method may interfere with the stability of the complex, thus leading to erroneous results.

As mentioned in the introduction, it is in principle possible to label the substance with 153Gd and to use gamma-counting for estimation of the Gd concentration in tissue samples. However, our experience (unpublished data) is that labelling with 153Gd causes radiolysis, which may destroy the chelate and cause release of Gd, leading to a gross overestimate of dechelation. Another challenge related to the use of 153Gd-labelled substance (if no excess chelate is added) is the quality control analyses needed to show that there is no free 153Gd in the substance injected. It should be noted that any attempt to analyse for free Gd by chromatographic methods also includes the risk that the free Gd will bind to the column material, thus underestimating the amount of free Gd present in the solution. It is well known that following intravenous injection of Gd salts such as GdCl3 in animals, aggregates of Gd are formed and are taken up by the reticuloendothelial system, including the liver, spleen and bone marrow [17]. Therefore, even minor amounts of free Gd in formulations of GBCAs injected into animals may lead to significantly increased uptake of Gd in these tissues, seriously interfering with the estimate of Gd uptake in tissue due to release from the chelate.

There are examples in the literature where the appropriate data to show the absence of free 153Gd in the injection solution are not given, but despite this, the 153Gd content of tissue samples is taken as evidence of released Gd [7, 8]. In addition, there are also studies with non-radiolabelled Gd where the presence of the metal in tissue samples is also interpreted as being due to Gd released from its chelate [912], although without also measuring the chelate. As shown from the present study, this cannot be taken as evidence of dechelation. Moreover, several authors have interpreted the Zn content in human urine following injection of various GBCAs to be due to differences in their stability [13, 14], without appreciating that the urine Zn content can be fully accounted for by Zn binding to the extra chelate present in the GBCA formulations (e.g. CaDTPA-BMA in Omniscan). Okazaki et al. [18] reported that 92% of CaDTPA-BMA injected into rats was excreted in urine in the same form as it was injected; approximately 7% was excreted as the ZnDTPA-BMA and approximately 1% as CuDTPA-BMA. By assuming a similar binding of Zn to CaDTPA-BMA in humans to that in rats, one should expect 7% of the injected dose of CaDTPA-BMA present in Omniscan to be excreted as ZnDTPA-BMA, corresponding to 0.35% of the injected dose of GdDTPA-BMA.

Several authors have reported increased concentrations of Gd in skin obtained from NSF patients, and have interpreted this as most likely to be due to accumulation within intracellular organelles, e.g. lysosomes, or to extracellular localisation of insoluble Gd phosphates [1921]. These authors did not consider the possibility of GBCAs taken up via endocytosis, e.g. in cells such as macrophages or fibroblasts. Further studies are needed to understand the exact localisation and form of Gd observed at these sites, as well as their relevance, if any, to the development of NSF.

In the present study we have investigated the fate of both Gd and chelate after intravenous injection of Omniscan spiked with Gd[14C]DTPA-BMA in normal male Sprague Dawley rats. It is not known to what extent the fate of the GBCA in rats resembles that in humans, or to what extent the slower excretion of GBCAs in patients with renal impairment will impact on the behaviour of GBCA following intravenous injection. Clearly, more work is needed to understand how GBCAs are linked to the aetiology of NSF.

Conclusion

To the best of our knowledge, the present investigation has for the first time measured the in vivo tissue concentration of both Gd and chelate (DTPA-BMA) after administration of Omniscan containing trace amounts of Gd[14C]DTPA-BMA. The clearance of both Gd and DTPA-BMA from tissue samples was practically identical. Most of the administered dose was excreted rapidly, with approximately 1% of the material still to be eliminated from the body at 24 h. The clearance of 14C-labelled substance and Gd was very similar in almost all tissue samples up to 3 days after injection. These data clearly show that measurements of Gd concentration in tissue samples cannot be used as a measure of Gd released from the chelate. Previous publications that have restricted tissue measurement to Gd only as an indication of in vivo dechelation should be reviewed in the light of the findings we have reported in this investigation.