Abstract
Aortic anastomotic leakage is an inevitable but intractable complication of surgery for type A dissection. The treatment has been mostly surgical with a high rate of morbidity and mortality. We describe a 54-year-old patient with anastomotic leakage after his secondary surgery for type A dissection. The leakage located at the proximal site of the stent-graft and fed the false lumen. We have performed a complete occlusion by transcatheter closure using Amplatzer Duct Occluder II.
Similar content being viewed by others
References
Concistrè G, Casali G, Santaniello E, Montalto A, Fiorani B, Dell’Aquila A, Musumeci F. Reoperation after surgical correction of acute type A aortic dissection: risk factor analysis. Ann Thorac Surg. 2012;93:450–5.
Luciani N, De Geest R, Lauria G, Lauria G, Farina P, Luciani M, Glieca F, Massetti M. Late reoperations after acute aortic dissection repair: single-center experience. Asian Cardiovasc Thorac Ann. 2015;23:787–94.
Kobuch R, Hilker M, Rupprecht L, Hirt S, Keyser A, Puehler T, Amman M, Zink W, Schmid C. Late reoperations after repaired acute type A aortic dissection. J Thorac Cardiovasc Surg. 2012;144:300–7.
Chiesa R, Bertoglio L, Kahlberg A, Rinaldi E, Tshomba Y, Melissano G. Redo surgery in ascending aorta and aortic arch. J Cardiovasc Surg (Torino). 2014;55:803–12.
Sakata T, Ueda H, Watanabe M, Kohno H, Tamura Y, Abe S, Inage Y, Ikeuchi H, Kanda T, Fujii M, Matsumiya G. Endovascular treatment for proximal anastomotic pseudoaneurysm after total arch replacement in Behcet’s disease. Ann Vasc Surg. 2016;34:272-e9.
Nørgaard A, Andersen LI, Haahr PE, Justesen P. Coil embolization of an anastomotic leak after ascending aorta replacement. Acta Radiol. 2008;49:510–2.
Zhao T, Lu M, So A, Wu W, Wang C, Xu Z, Jiang S, Tian L, Liu S, Zhao S. Transcatheter closure of coronary artery fistulae: initial human experience with the Amplatzer duct occluder II. J Interv Cardiol. 2013;26:359–65.
Cwikiel W, Keussen I, Gustafsson R, Mokhtari A. Endovascular treatment of two pseudoaneurysms originating from the left ventricle. Cardiovasc Intervent Radiol. 2013;36:1677–80.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
None.
Ethics Statement
The procedure performed in studies involving human participant was in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Rights and permissions
About this article
Cite this article
Pu, J., Huang, L. & Wu, W. Transcatheter Closure of Anastomotic Leakage After Aortic Surgery for Type A Dissection with the Amplatzer Duct Occluder II. Cardiovasc Intervent Radiol 40, 1274–1277 (2017). https://doi.org/10.1007/s00270-017-1640-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-017-1640-2