Skip to main content
Log in

Heparin-Coated Angiographic Catheters: An In Vivo Comparison of Three Coating Methods with Different Heparin Release Profiles

  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

We evaluated in vivo anti-thrombogenic effects of three different heparin-coated angiographic catheters with different heparin release profiles. Three different types of heparin-coated 5 French angiographic catheters (rapidly-heparin-releasing, slowly-heparin-releasing, and heparin-adherent catheters) were prepared by coating amphiphilic or hydrophobic heparin derivatives in order to regulate heparin elution. After incubation time of 30 minutes in the arteries of dogs, the amount of thrombus deposition, measured as dry weight, was compared in 10 sets of the three heparin-coated catheters and a non-coated catheter used as control. The surface morphology of catheters after their withdrawal was studied by scanning electron microscopy. The amount of thrombus deposition on the non-coated catheter (374.6 ± 11.6 mg, mean ± SD) was significantly larger than those on the rapidly-heparin-releasing (52.0 ± 12.6), slowly-heparin-releasing (70.4 ± 23.1), and heparin-adherent catheters (103.7 ± 39.9) (p < 0.001, each). The thrombus weights in the three heparin-coated catheters were not statistically different. The scanning electron microscopy showed crusts on the catheter surface, which were thickest in the non-coated catheters. We concluded that the thrombus formation inside a catheter is significantly decreased if the catheter is treated with any of the three heparin-coating methods used in this study. The in vivo anti-thrombogenic effects of these coating methods are not significantly different despite their different heparin release profiles.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.

Similar content being viewed by others

References

  1. G Haut K Amplatz (1968) ArticleTitleComplication rates of transfemoral and transaortic catheterization Surgery 63 594–596 Occurrence Handle1:STN:280:CCeC1Mrpslc%3D Occurrence Handle5645377

    CAS  PubMed  Google Scholar 

  2. G Formanek RS Frech K Amplatz (1970) ArticleTitleArterial thrombus formation during clinical percutaneous catheterization Circulation 41 833–839 Occurrence Handle1:STN:280:CS%2BC1cvptlA%3D Occurrence Handle5444526

    CAS  PubMed  Google Scholar 

  3. GC Ooi AR Jones GN Rutty (1993) ArticleTitleCase report: thromboembolism during transfemoral arteriography-radiographic demonstration with histopathological correlation Clin Radiol 48 280–282

    Google Scholar 

  4. A Soeda N Sakai H Sakai K Iihara N Yamada S Imakita I Nagata (2003) ArticleTitleThromboembolic events associated with Guglielmi detachable coil embolization of asymptomatic cerebral aneurysms: evaluation of 66 consecutive cases with use of diffusion-weighted MR imaging Am J Neuroradiol 24 127–132

    Google Scholar 

  5. DK Kido S Paulin JA Alenghat C Waternaux WD Riley (1982) ArticleTitleThrombogenicity of heparin- and non-heparin-coated catheters: clinical trail Am J Roentgenol 139 957–961 Occurrence Handle1:STN:280:BiyD3MbksFI%3D

    CAS  Google Scholar 

  6. PS Damus M Hicks RB Rosenberg (1977) ArticleTitleAnticoagulant action of heparin Nature 246 355–355

    Google Scholar 

  7. SC Vasudev T Chandy CP Sharma (1997) ArticleTitleDevelopment of chitosan/polyethylene vinyl acetate co-matrix: controlled release of aspirin-heparin for preventing cardiovascular thrombosis Biomaterials 18 375–381 Occurrence Handle10.1016/S0142-9612(96)00131-7 Occurrence Handle1:CAS:528:DyaK2sXhsFSmu7o%3D Occurrence Handle9061177

    Article  CAS  PubMed  Google Scholar 

  8. LA Orloff MG Glenn AJ Domb RA Esclamado (1995) ArticleTitlePrevention of venous thrombosis in microvascular surgery by transmural release of heparin from a polyanhydride polymer Surgery 117 554–559 Occurrence Handle1:STN:280:ByqB2MfptlA%3D Occurrence Handle7740427

    CAS  PubMed  Google Scholar 

  9. GM Bernacca MJ Gulbransen R Wilkinson DJ Wheatley (1998) ArticleTitleIn vitro blood compatibility of surface-modified polyurethanes Biomaterials 19 1151–1165 Occurrence Handle10.1016/S0142-9612(98)00016-7 Occurrence Handle1:CAS:528:DyaK1cXltFOmtrk%3D Occurrence Handle9720899

    Article  CAS  PubMed  Google Scholar 

  10. KD Park T Okano C Nojiri SW Kim (1988) ArticleTitleHeparin immobilization onto segmented polyurethane-urea surfaces—effect of hydrophilic spacers J Biomed Mater Res 22 977–992 Occurrence Handle1:CAS:528:DyaL1MXmtlKluw%3D%3D Occurrence Handle3241011

    CAS  PubMed  Google Scholar 

  11. PF Hoar RM Wilson DT Mangano GJ Avery 2nd RJ Szarnicki JD Hill (1981) ArticleTitleHeparin bonding reduces thrombogenicity of pulmonary-artery catheters N Engl J Med 305 993–995 Occurrence Handle1:STN:280:Bi2D3Mzlt1I%3D Occurrence Handle7024812

    CAS  PubMed  Google Scholar 

  12. DT Mangano (1982) ArticleTitleHeparin bonding and long-term protection against thrombogenesis N Engl J Med 307 894–895 Occurrence Handle1:STN:280:Bi2B2s3itlE%3D Occurrence Handle7110267

    CAS  PubMed  Google Scholar 

  13. R Cramer R Moore K Amplatz (1973) ArticleTitleReduction of the surgical complication rate by the use of a hypothrombogenic catheter coating Radiology 109 585–588 Occurrence Handle1:STN:280:CSuD1c%2FnvVM%3D Occurrence Handle4772170

    CAS  PubMed  Google Scholar 

  14. AG Randolph DJ Cook CA Gonzales M Andrew (1998) ArticleTitleBenefit of heparin in central venous and pulmonary artery catheters: a meta-analysis of randomized controlled trials Chest 113 165–171 Occurrence Handle1:CAS:528:DyaK1cXptFOmtA%3D%3D Occurrence Handle9440585

    CAS  PubMed  Google Scholar 

  15. B Krafte-Jacobs CJ Sivit R Mejia MM Pollack (1995) ArticleTitleCatheter-related thrombosis in critically ill children: comparison of catheters with and without heparin bonding J Pediatr 126 50–54 Occurrence Handle1:STN:280:ByqC3MvnslU%3D Occurrence Handle7815223

    CAS  PubMed  Google Scholar 

  16. K Bennegard I Curelaru B Gustavsson LE Linder BF Zachrisson (1982) ArticleTitleMaterial hrombogenicity in central venous catheterization. I. A comparison between uncoated and heparin-coated, long antebrachial, polyethylene catheters Acta Anaesthesiol Scand 26 112–120 Occurrence Handle1:STN:280:Bi2B2MzgsFM%3D Occurrence Handle7048839

    CAS  PubMed  Google Scholar 

  17. GH Engbers L Dost WE Hennink PA Aarts JJ Sixma J Feijen (1987) ArticleTitleAn in vitro study of the adhesion of blood platelets onto vascular catheters. Part I J Biomed Mater Res 21 613–627 Occurrence Handle1:STN:280:BiiB383ksFA%3D Occurrence Handle3584166

    CAS  PubMed  Google Scholar 

  18. P Mollenholt I Eriksson T Andersson (1987) ArticleTitleThrombogenicity of pulmonary artery catheters Intensive Care Med 13 57–59 Occurrence Handle1:STN:280:BiiC28jgt1w%3D Occurrence Handle3558936

    CAS  PubMed  Google Scholar 

  19. M Ernofsson S Thelin A Siegbahn (1995) ArticleTitleThrombin generation during cardiopulmonary bypass using heparin-coated or standard circuits Scand J Thorac Cardiovasc Surg 29 157–165 Occurrence Handle1:STN:280:BymA1c7ksFE%3D Occurrence Handle8789468

    CAS  PubMed  Google Scholar 

  20. RS Okor W Anderson (1987) ArticleTitleCasting solvent effects on the permeability of polymer films of differing quaternary ammonium (cation) content J Pharm Pharmacol 39 547–548 Occurrence Handle1:CAS:528:DyaL2sXkvVersrk%3D Occurrence Handle2886624

    CAS  PubMed  Google Scholar 

  21. Y Lee HT Moon Y Byun (1998) ArticleTitlePreparation of slightly hydrophobic heparin derivatives which can be used for solvent casting in polymeric formulation Thromb Res 92 149–156 Occurrence Handle10.1016/S0049-3848(98)00124-8 Occurrence Handle1:CAS:528:DyaK1cXns1GltL0%3D Occurrence Handle9840023

    Article  CAS  PubMed  Google Scholar 

  22. HT Moon YK Lee JK Han Y Byun (2001) ArticleTitleA novel formulation for controlled release of heparin-DOCA conjugate dispersed as nanoparticles in polyurethane film Biomaterials 22 281–289 Occurrence Handle10.1016/S0142-9612(00)00194-0 Occurrence Handle1:STN:280:DC%2BD3M7ltlyrtw%3D%3D Occurrence Handle11197503

    Article  CAS  PubMed  Google Scholar 

  23. CM Pierce A Wade Q Mok (2000) ArticleTitleHeparin-bonded central venous lines reduce thrombotic and infective complications in critically ill children Intensive Care Med 26 967–972 Occurrence Handle10.1007/s001340051289 Occurrence Handle1:STN:280:DC%2BD3cvkt1Wluw%3D%3D Occurrence Handle10990114

    Article  CAS  PubMed  Google Scholar 

  24. LA Mermel SM Stolz DG Maki (1993) ArticleTitleSurface antimicrobial activity of heparin- bonded and antiseptic-impregnated vascular catheters J Infect Dis 167 920–924 Occurrence Handle1:STN:280:ByyC1MrjvFE%3D Occurrence Handle8450256

    CAS  PubMed  Google Scholar 

  25. C Arnander D Bagger-Sjoback S Frebelius R Larsson J Swedenborg (1987) ArticleTitleLong-term stability in vivo of a thromboresistant heparinized surface Biomaterials 8 496–499 Occurrence Handle10.1016/0142-9612(87)90088-3 Occurrence Handle1:CAS:528:DyaL1cXhtVWhu7c%3D Occurrence Handle3427150

    Article  CAS  PubMed  Google Scholar 

  26. K Amplatz (1976) ArticleTitleA new, simple test for thrombogenicity Radiology 120 53–55 Occurrence Handle1:STN:280:CSmB38zjsVY%3D Occurrence Handle935464

    CAS  PubMed  Google Scholar 

  27. RS Frech R Cramer K Amplatz (1971) ArticleTitleA simple noninvasive technique to test nonthrombogenic surfaces. Direct visualization of experimental thrombus formation around guidewires Am J Roentgenol Radium Ther Nucl Med 113 765–768 Occurrence Handle1:CAS:528:DyaE38XhtVeksLo%3D Occurrence Handle5128142

    CAS  PubMed  Google Scholar 

  28. S Durst R Cramer K Amplatz (1973) ArticleTitleFlow cell evaluation of nonthrombogenic materials Radiology 106 507–511 Occurrence Handle1:CAS:528:DyaE3sXktFGht70%3D Occurrence Handle4684789

    CAS  PubMed  Google Scholar 

  29. VL Gott DE Koepke RL Daggett (1961) ArticleTitleThe coating of intravascular plastic prostheses with colloidal graphite Surgery 50 382–389 Occurrence Handle1:STN:280:CC%2BD38npsVY%3D Occurrence Handle13707428

    CAS  PubMed  Google Scholar 

  30. R Cramer RS Frech K Amplatz (1971) ArticleTitleA preliminary human study with a simple nonthrombogenic catheter Radiology 100 421–422 Occurrence Handle1:STN:280:CS2C28bntVE%3D Occurrence Handle5147411

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Joon Koo Han.

Additional information

This study was supported in part by the Korean Ministry of Health and Welfare (grant HMP-98-G-2-034).

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lee, K., Han, J., Byun, Y. et al. Heparin-Coated Angiographic Catheters: An In Vivo Comparison of Three Coating Methods with Different Heparin Release Profiles. CVIR 27, 507–511 (2004). https://doi.org/10.1007/s00270-003-4035-5

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-003-4035-5

Navigation