Skip to main content
Log in

A comparison of targetting of neuroblastoma with mIBG and anti L1-CAM antibody mAb chCE7: therapeutic efficacy in a neuroblastoma xenograft model and imaging of neuroblastoma patients

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Iodine-131 labelled anti L1-CAM antibody mAb chCE7 was compared with the effective neuroblastoma-seeking agent 131I-labelled metaiodobenzylguanidine (MIBG) with regard to (a) its therapeutic efficacy in treating nude mice with neuroblastoma xenografts and (b) its tumour targetting ability in neuroblastoma patients. The SK-N-SH tumour cells used in the mouse experiments show good MIBG uptake and provide a relatively low number of 6,300 binding sites/cell for mAb chCE7. Tumours were treated with single injections of 131I-MIBG (110 MBq) and with 131I-labelled mAb chCE7 (17 MBq) and both agents showed antitumour activity. After therapy with 131I-chCE7, the subcutaneous tumours nearly disappeared; treatment with 131I-MIBG was somewhat less effective, resulting in a 70% reduction in tumour volume. A calculated tumour regrowth delay of 9 days occurred with a radioactivity dose of 17 MBq of an irrelevant control antibody mAb 35, which does not bind to SK-N-SH cells, compared with a regrowth delay of 34 days with 131I-mAb chCE7 and of 24 days with 131I-MIBG. General toxicity appeared to be mild, as assessed by a transient, approximate 10% maximum decrease in body weight during the treatments. The superior growth inhibition achieved by 131I-chCE7 compared with 131I-MIBG can be explained by its prolonged retention in the tumours, due to slower normal tissue and plasma clearance. Cross-reaction of mAb chCE7 with L1-CAM present in normal human tissues was investigated by direct binding of radioiodinated mAb to frozen tissue sections. Results showed a strong reaction with normal human brain tissue and weak but detectable binding to normal adult kidney sections. Seven patients with recurrent neuroblastoma were sequentially imaged with 131I-MIBG and 131I-chCE7. The results underlined the heterogeneity of neuroblastoma and showed the two imaging modalities to be complementary. 131I-chCE7 scintigraphy may have clinical utility in detecting metastases which do not accumulate 131I-MIBG, and the antibody may hold potential for radioimmunotherapy, either by itself or in combination with 131I-MIBG.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 21 August and in revised form 20 November 2000

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hoefnagel, C.A., Rutgers, M., Buitenhuis, C.K.M. et al. A comparison of targetting of neuroblastoma with mIBG and anti L1-CAM antibody mAb chCE7: therapeutic efficacy in a neuroblastoma xenograft model and imaging of neuroblastoma patients. Eur J Nucl Med 28, 359–368 (2001). https://doi.org/10.1007/s002590000454

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590000454

Navigation